Canada · Provincial and territorial regulators (syllabus by Engineers Canada)
390practice questions written to this syllabus
20subjects
What Engineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus is
Engineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus is a licensing and registration exam run by Provincial and territorial regulators (syllabus by Engineers Canada), for candidates in Canada.
Format
Written confirmatory exams for graduates of non-CEAB programmes, assigned case by case.
Sections
Group A (6 of 7): applied plant/animal/human physiology; soil physics and mechanics; heat engineering; fluid flow; instrumentation; physical properties of biological materials and foods; food chemistry and microbiology
Group B (3 of 15): materials handling; structural design; machine design; machinery analysis; power units; irrigation, drainage and erosion control; hydrology; food process engineering 1 and 2; biochemical engineering; waste management; biological waste treatment; control and monitoring; aquacultural engineering; building design
How it has changed
CEAB-accredited graduates do not sit these. Exam codes suggest a 2022 edition (inference).
How to prepare for Engineers Canada Agricultural / Biosystems / Bioresource / Food Engineering examination syllabus
Where our 390 questions for it fall
Our reading of the syllabus, from the questions we have written to this exam; the exam body's own weighting, where published, is under Format above.
Heaviest (75% of the questions): Agricultural Waste Management & Environmental Engineering (97); Aquacultural & Forest Engineering (regional) (60); Heat & Mass Transfer (37); Instrumentation, Sensors & Process Control (37); Soil Mechanics (26); Protected Cultivation & Greenhouse Engineering (22); Watershed Hydrology (13).
Start here: read these subjects' manuals first and work their questions until the reasoning is automatic.
Middle band: Engineering Properties of Agricultural Produce (13); Food & Dairy Engineering (13); Storage Engineering, Material Handling & Packaging (11); Agricultural Structures & Environmental Control (11); Soil Science for Engineers (10); Watershed Planning & Management (10); Engineering Thermodynamics (7).
One pass per subject, then mixed sets across them.
Lighter: Crop Production & Protection for Engineers (6); Agricultural Drainage Engineering (6); Fluid Mechanics & Open Channel Hydraulics (5); Building Materials, Theory of Structures & Construction (3); Post-Harvest Engineering of Horticultural Crops (2); Soil & Water Conservation Engineering (1).
Definitions, classifications and standard figures; quick to revise, easy marks to lose.
Hardest share: Heat & Mass Transfer (26 hard of 37), Soil Science for Engineers (6 hard of 10), Post-Harvest Engineering of Horticultural Crops (1 hard of 2).
Leave untimed time for these and read every explanation, including for the options you rejected.
Original questions written to this exam's published syllabus and pattern. Not past papers.
1. Which laboratory test is appropriate for measuring the permeability of a silty clay?
Constant-head test
Proctor compaction test
Falling-head test
Dry sieve analysis
Answer and working
C. Falling-head test
In fine-grained soils so little water passes that a constant-head test cannot measure the flow accurately; the falling-head test measures the fall in a narrow standpipe instead. The constant-head test suits sands and gravels.
Soil Mechanics · Permeability
2. Why is derivative action in a PID controller often applied to the measured variable rather than the error, and filtered?
To make the derivative term remove steady-state offset, which it cannot do on the error signal
To slow the loop so that it never overshoots, whatever proportional gain is chosen by the user
To avoid a large output spike when the setpoint is stepped, and to limit amplification of noise
To convert the PID into an on-off controller during large setpoint changes to save energy
Answer and working
C. To avoid a large output spike when the setpoint is stepped, and to limit amplification of noise
A setpoint step makes de/dt very large for an instant (derivative kick); using the measured variable avoids this because the measurement changes smoothly. Derivative amplifies high-frequency noise, so a filter is added. Derivative never removes offset.
Instrumentation, Sensors & Process Control · Control modes: on-off, P, PI and PID
3. A 3-month Standardized Precipitation Index (SPI) value of −1.7 falls in the class:
moderately dry
severely dry
extremely dry
near normal
Answer and working
B. severely dry
SPI −1.5 to −1.99 is severely dry; −1.0 to −1.49 moderately dry; −2.0 or less extremely dry.
Watershed Hydrology · Drought classification
4. In forced-aeration composting, the airflow needed to remove heat and hold temperature is far greater than that needed to supply oxygen for decomposition. The design consequence is that:
Moisture is gained as air passes, so the pile needs no water management
Aeration fans are sized from the stoichiometric oxygen demand of the feedstock alone
Aeration is controlled by temperature feedback rather than oxygen demand alone
Aeration should be stopped once the pile reaches 70 °C to save energy
Answer and working
C. Aeration is controlled by temperature feedback rather than oxygen demand alone
Heat removal dominates airflow requirements, so fans are sized and controlled for temperature, and the large airflow dries the pile, making moisture addition necessary. Stopping aeration at high temperature lets the pile overheat further.
5. The cross-section of grain on a troughed belt is 0.02 m² and the belt runs at 2.0 m/s. Grain bulk density is 750 kg/m³. Capacity?
30 t/h
389 t/h
108 t/h
144 t/h
Answer and working
C. 108 t/h
Q = A·v·ρ = 0.02 × 2.0 × 750 = 30 kg/s = 30 × 3.6 = 108 t/h. 30 is the kg/s figure mislabelled as t/h. 144 t/h is the volume flow in m³/h mislabelled; 389 t/h applies the ×3.6 conversion twice.
Storage Engineering, Material Handling & Packaging · Design of conveyors and elevators
6. In a moving-bed bioreactor (MBBR), the nitrifying bacteria grow on
the walls of the fish tank, cleaned once a week by brushing
a fixed bed of gravel through which water is pumped upward
plastic carriers kept in suspension and circulation in the reactor
fine sand fluidised by an upflow of water in a column
Answer and working
C. plastic carriers kept in suspension and circulation in the reactor
MBBR carriers move freely in an aerated or mixed tank. Fixed gravel beds, tank walls and fluidised sand are other biofilm arrangements.
Aquacultural & Forest Engineering (regional) · Recirculating aquaculture systems
7. Which statement about NTC thermistors compared with platinum RTDs is correct?
They are far more sensitive per degree but strongly non-linear over a wide range
They are more linear than RTDs and therefore need no calibration equation at all
Their resistance rises with temperature at about ten times the rate of platinum
They suit higher temperatures than RTDs, such as furnace and flue-gas measurement
Answer and working
A. They are far more sensitive per degree but strongly non-linear over a wide range
NTC thermistors change by roughly 3–5% per °C near room temperature, about ten times the change of platinum, but their resistance falls (not rises) exponentially with temperature, so the beta or Steinhart–Hart equation is needed. Their usable range is narrower than that of RTDs and thermocouples.
Instrumentation, Sensors & Process Control · Temperature transducers
8. In the United States, small watershed projects planned with local sponsors for flood prevention and conservation are funded under:
the Watershed Protection and Flood Prevention Act of 1954 (Public Law 83-566)
the Tennessee Valley Authority Act of 1933 (TVA Act) only
the Clean Air Act
the Homestead Act
Answer and working
A. the Watershed Protection and Flood Prevention Act of 1954 (Public Law 83-566)
PL 83-566 authorises federal help, through the Soil Conservation Service (now the Natural Resources Conservation Service), for watershed projects sponsored by local organisations. The TVA of 1933 is a basin authority for one river system; the Clean Air and Homestead Acts are unrelated.
Watershed Planning & Management · National watershed programmes