LAISHA
Open Laisha

Central and State Pollution Control Board recruitment (Scientist, Environmental Engineer, AEE)

India · Central Pollution Control Board and State Pollution Control Boards / state PSCs · unverified source

162practice questions written to this syllabus
12subjects

What Central and State Pollution Control Board recruitment is

Central and State Pollution Control Board recruitment (Scientist, Environmental Engineer, AEE) is a government recruitment exam run by Central Pollution Control Board and State Pollution Control Boards / state PSCs, for candidates in India.

Format

Varies by board: written objective or descriptive test in environmental science or engineering, sometimes with interview.

Sections

We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose.

Check the current format, eligibility, fees and dates on the official site: cpcb.nic.in.

How it has changed

Each board recruits on its own notification; there is no single syllabus. The GATE ES syllabus and UGC NET Environmental Sciences cover most technical content.

How to prepare for Central and State Pollution Control Board recruitment

Where our 162 questions for it fall

Our reading of the syllabus, from the questions we have written to this exam; the exam body's own weighting, where published, is under Format above.

  1. Heaviest (55% of the questions): Circular Economy & Bio-based Resources (26); Environmental Monitoring & Instrumental Analysis (23); Air & Noise Pollution: Monitoring & Control (23); Environmental Impact Assessment & Strategic Environmental Assessment (17).

    Start here: read these subjects' manuals first and work their questions until the reasoning is automatic.

  2. Middle band: Environmental Microbiology (15); Environmental Law, Policy & International Agreements (14); Water & Wastewater Treatment (12); Wetlands, Coastal Ecosystems & Blue Carbon (10).

    One pass per subject, then mixed sets across them.

  3. Lighter: Environmental Chemistry (8); Solid & Hazardous Waste Management (7); Environmental Management Systems, Auditing & Standards (4); Soil Contamination, Toxicology & Remediation (3).

    Definitions, classifications and standard figures; quick to revise, easy marks to lose.

  4. Hardest share: Environmental Impact Assessment & Strategic Environmental Assessment (5 hard of 17), Environmental Microbiology (3 hard of 15), Wetlands, Coastal Ecosystems & Blue Carbon (2 hard of 10).

    Leave untimed time for these and read every explanation, including for the options you rejected.

Official source: cpcb.nic.in

8 practice questions, worked

Original questions written to this exam's published syllabus and pattern. Not past papers.

1. A café switches to PLA cups labelled 'compostable', but the city has no industrial composting and collects them with general waste for landfill. What is the most accurate assessment?

  1. The cups will compost in landfill within six months, as EN 13432 guarantees in any disposal setting worldwide
  2. The compostability claim brings no end-of-life benefit there, because the required composting is absent
  3. The cups will be recycled with PET bottles, because PLA and PET are the same polymer
  4. The cups remove all life cycle impacts, because bio-based materials are carbon neutral
Answer and working

B. The compostability claim brings no end-of-life benefit there, because the required composting is absent

PLA needs industrial composting temperatures; in landfill it degrades very slowly. EN 13432 conditions are those of controlled composting, PLA contaminates PET recycling, and bio-based materials still carry production impacts.

Circular Economy & Bio-based Resources · Bio-based and biodegradable materials: claims and evidence

2. A groundwater has electrical conductivity of 1500 µS/cm. Using a conversion factor of 0.64, estimate its TDS and compare it with the IS 10500 acceptable limit.

  1. About 2340 mg/L, above the 2000 mg/L permissible limit
  2. About 96 mg/L, well within the acceptable limit
  3. About 960 mg/L, above the 500 mg/L acceptable limit
  4. About 1500 mg/L, exactly at the acceptable limit
Answer and working

C. About 960 mg/L, above the 500 mg/L acceptable limit

TDS ≈ 0.64 × 1500 = 960 mg/L, exceeding the acceptable 500 mg/L but within the permissible 2000 mg/L. Dividing gives 2340; 96 slips a factor of ten.

Environmental Chemistry · Water quality parameters and their measurement

3. Typical untreated domestic sewage has a BOD5 of roughly:

  1. 5,000-10,000 mg/L
  2. 150-350 mg/L
  3. 5-15 mg/L
  4. 50,000-60,000 mg/L
Answer and working

B. 150-350 mg/L

5-15 mg/L is treated effluent; tens of thousands is distillery spentwash.

Water & Wastewater Treatment · Water and wastewater quality parameters: BOD, COD, solids, nutrients

4. How is balancing storage for a service reservoir found from a mass curve?

  1. Peak hourly demand multiplied by 24 hours
  2. Fire demand plus a fixed safety margin
  3. Average daily demand of the town only
  4. Maximum surplus plus maximum deficit
Answer and working

D. Maximum surplus plus maximum deficit

Storage must absorb the largest surplus and supply the largest deficit.

Water & Wastewater Treatment · Water distribution and storage

5. In which year was India's National Clean Air Programme launched?

  1. 1981
  2. 2006
  3. 2019
  4. 2022
Answer and working

C. 2019

NCAP was launched in 2019 to reduce particulate pollution in non-attainment cities. 1981 is the Air Act; 2006 the National Environment Policy; 2022 Mission LiFE.

Environmental Law, Policy & International Agreements · Environmental policy and national environment policies

6. What is the typical food-to-microorganism (F/M) ratio for conventional activated sludge?

  1. About 0.001 kg BOD per kg MLVSS per day
  2. About 5–10 kg BOD per kg MLVSS per day
  3. About 0.2–0.5 kg BOD per kg MLVSS per day
  4. About 50 kg BOD per kg MLVSS per day
Answer and working

C. About 0.2–0.5 kg BOD per kg MLVSS per day

Conventional plants run around 0.2–0.5; extended aeration lower; high-rate processes higher.

Environmental Microbiology · Batch and continuous culture

7. Which electrode is a standard method for measuring fluoride in drinking water?

  1. Platinum ORP electrode
  2. Glass pH electrode
  3. Lanthanum fluoride ISE
  4. Clark oxygen electrode
Answer and working

C. Lanthanum fluoride ISE

The LaF3 crystal ISE responds to fluoride; TISAB fixes ionic strength and releases complexed fluoride.

Environmental Monitoring & Instrumental Analysis · Electrochemical methods and sensors

8. Under India's tariff policy, which plants must use treated sewage where available within a set distance?

  1. Solar parks
  2. Wind farms
  3. Hydropower dams
  4. Thermal power plants
Answer and working

D. Thermal power plants

Cooling water demand can be met with treated sewage.

Water & Wastewater Treatment · Common effluent treatment plants, recycling and zero liquid discharge

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock all 162 questions — Central and State Pollution Control Board recruitment (Scientist, Environmental Engineer,

US$10 a month · one price worldwide · cancel any time

  • Every practice question for this course, with explanations
  • Timed papers for the exams this course leads to
  • Ask Laisha to explain any topic — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.