National Technical Qualification General Microbiology: practice questions
National Technical Qualification — Food Engineer (식품기사) and Food Industrial Engineer (식품산업기사) · South Korea · Human Resources Development Service of Korea (HRDK), Q-Net
Original practice questions written to the published syllabus · not past papers
10worked here, free
21written to this exam in this subject
10syllabus units
About National Technical Qualification
National Technical Qualification — Food Engineer (식품기사) and Food Industrial Engineer (식품산업기사) is a licensing and registration exam run by Human Resources Development Service of Korea (HRDK), Q-Net, for candidates in South Korea. Written examination followed by a practical examination; graded national technical qualifications.
We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.
General Microbiology in National Technical Qualification
The microbial world before it meets food: cell structure, staining, growth, nutrition, genetics and control of bacteria, yeasts, moulds and viruses. Food microbiology (phase 2) builds directly on it.
Our 21 National Technical Qualification questions in this subject: 4 easy, 12 medium, 5 hard, across 10 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
Question 1 · medium
An analyst leaves the decolouriser on a Gram smear of Staphylococcus aureus for far too long. The most likely result is:
No change, because Gram-positive cells cannot lose dye
All cells appear green from the malachite green
Cells appear pink, a false Gram-negative reaction
Cells appear purple with red endospores inside
Answer and working
C. Cells appear pink, a false Gram-negative reaction
Over-decolourisation removes the complex even from Gram-positive cells; this is the critical step. Malachite green is the spore stain.
Question 2 · medium
A phage suspension diluted 10⁻⁶ gives 85 plaques when 0.1 mL is plated with host bacteria. The titre is:
8.5 × 10⁹ PFU/mL
8.5 × 10⁵ PFU/mL
8.5 × 10⁷ PFU/mL
8.5 × 10⁸ PFU/mL
Answer and working
D. 8.5 × 10⁸ PFU/mL
Titre = 85 ÷ (0.1 × 10⁻⁶) = 8.5 × 10⁸ PFU/mL. 8.5 × 10⁷ forgets the 0.1 mL volume.
Question 3 · hard
A pour plate of 1 mL from the 10⁻⁴ dilution has 87 colonies. The count is:
8.7 × 10⁵ CFU/g
8.7 × 10³ CFU/g
8.7 × 10⁴ CFU/g
8.7 × 10⁶ CFU/g
Answer and working
A. 8.7 × 10⁵ CFU/g
87 ÷ (1 × 10⁻⁴) = 8.7 × 10⁵ CFU/g.
Question 4 · hard
Duplicate 1 mL pour plates give 232 and 244 colonies at 10⁻², and 33 and 28 at 10⁻³. Using the ISO 7218 weighted mean N = ΣC / [V(n1 + 0.1n2)d], the count is:
3.1 × 10⁴ CFU/g
2.7 × 10⁴ CFU/g
2.4 × 10³ CFU/g
2.4 × 10⁴ CFU/g
Answer and working
D. 2.4 × 10⁴ CFU/g
ΣC = 232 + 244 + 33 + 28 = 537; n1 = 2, n2 = 2; N = 537 ÷ (1 × 2.2 × 10⁻²) = 24 409 ≈ 2.4 × 10⁴. 3.1 × 10⁴ comes from averaging only the 10⁻³ plates (30.5 × 10³); 2.4 × 10³ uses d = 10⁻³.
Question 5 · medium
With D121 = 0.21 min for Clostridium botulinum spores, the 12D process at 121 °C is:
2.52 min
1.26 min
0.21 min
12.21 min
Answer and working
A. 2.52 min
F = 12 × 0.21 = 2.52 min. 1.26 is 6D; 12.21 adds instead of multiplying.
Question 6 · medium
A heat-sensitive vitamin solution must be sterilised for a culture medium. The appropriate method is:
Hot-air oven at 160 °C for 2 hours
Boiling for 10 minutes
Autoclaving at 121 °C for 15 minutes
Membrane filtration through a 0.22 µm filter
Answer and working
D. Membrane filtration through a 0.22 µm filter
Filtration removes bacteria without heat. The other methods would destroy the vitamin.
Question 7 · easy
An inoculating loop is correctly sterilised by:
Dipping in 70% ethanol and using it while wet
Rinsing in sterile water between samples
Wiping with a dry tissue between each transfer
Flaming until red hot, then cooling it briefly
Answer and working
D. Flaming until red hot, then cooling it briefly
Flaming to red heat incinerates organisms; the loop must cool so it does not kill the inoculum. Ethanol does not kill spores.
Question 8 · medium
Which biological safety cabinet protects the worker, the environment and the sample, and is used for routine work with risk group 2 food pathogens?
Chemical fume hood
Horizontal laminar-flow clean bench
Class I
Class II
Answer and working
D. Class II
Class II adds HEPA-filtered downflow over the work. Class I protects worker and environment but not the sample; a clean bench blows air at the worker and protects only the product.
Question 9 · medium
A horizontal laminar-flow clean bench is unsuitable for work with Salmonella because:
It blows filtered air from the work surface towards the operator
It lacks a UV lamp to sterilise the work surface between uses
It operates at a negative pressure that dries out the plates
Its HEPA filter removes Salmonella from the cultures being handled
Answer and working
A. It blows filtered air from the work surface towards the operator
It protects only the product; aerosols are blown into the worker's face.
Question 10 · easy
Most food-borne bacterial pathogens such as Salmonella and Listeria monocytogenes are handled in the laboratory as:
Risk group 1 organisms
Risk group 4 organisms
Risk group 2 organisms
Organisms with no risk classification
Answer and working
C. Risk group 2 organisms
They can cause disease but are unlikely to spread widely and treatment exists; classification of individual strains varies between national schemes.
A study plan for General Microbiology in National Technical Qualification
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (67% of the 21 questions): Aseptic technique and laboratory biosafety (5, 24%); Measurement of growth: serial dilution, plate count, MPN and turbidity (4, 19%); Control of microorganisms: physical and chemical agents and death kinetics (3, 14%); Microbial nutrition and culture media (2, 10%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Viruses and bacteriophages (2, 10%); Bacteria, yeasts, moulds and actinomycetes: morphology and classification (1, 5%); Microbial genetics: mutation, plasmids, transformation, transduction and conjugation (1, 5%); Microscopy: light, phase-contrast, fluorescence and electron (1, 5%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Prokaryotic and eukaryotic cell structure; spores and vegetative cells (1, 5%); Staining: simple, Gram, acid-fast and endospore (1, 5%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Microbial genetics: mutation, plasmids, transformation, transduction and conjugation (1 hard of 1), Microscopy: light, phase-contrast, fluorescence and electron (1 hard of 1), Prokaryotic and eukaryotic cell structure; spores and vegetative cells (1 hard of 1).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Aseptic technique and laboratory biosafety (2 easy of 5); Control of microorganisms: physical and chemical agents and death kinetics (1 easy of 3).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.