GARP Sustainability and Climate Risk Certificate Energy, Environment & Agri-energy Transitions: practice questions
GARP Sustainability and Climate Risk (SCR) Certificate · International · Global Association of Risk Professionals
Original practice questions written to the published syllabus · not past papers
7worked here, free
16written to this exam in this subject
8syllabus units
About GARP Sustainability and Climate Risk Certificate
GARP Sustainability and Climate Risk (SCR) Certificate is a professional certification run by Global Association of Risk Professionals, for candidates worldwide. 80 multiple-choice questions and one multi-part case study, 4 hours, pass/fail. Offered in April and October windows. GARP suggests 100–150 hours of preparation.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Energy, Environment & Agri-energy Transitions in GARP Sustainability and Climate Risk Certificate
Energy systems and their environmental footprints, and the transition in agriculture: fossil and renewable sources, energy-environment nexus, energy efficiency and auditing, and agri-energy options. Solar, wind and bioenergy engineering is in the Agricultural Engineering track (renewable-energy-sources, bioenergy-systems); this subject covers the environmental assessment and policy.
Our 16 GARP Sustainability and Climate Risk Certificate questions in this subject: 0 easy, 12 medium, 4 hard, across 8 units.
7 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 7 were written to GARP Sustainability and Climate Risk Certificate and are not shown on any other exam's page.
Question 1 · hard
Why is the climate constraint now considered more binding than fossil resource depletion?
Carbon budgets have no relation to cumulative fossil fuel use
Renewable resources are smaller than human energy demand
Fossil reserves will be fully exhausted within ten years at current use
Burning proved reserves would exceed Paris carbon budgets
Answer and working
D. Burning proved reserves would exceed Paris carbon budgets
Proved fossil reserves contain more carbon than remaining budgets for 1.5–2 °C allow. Reserves last decades or more; renewable flows far exceed demand; budgets are directly tied to cumulative CO2.
Question 2 · hard
Why can mechanisation increase energy use per hectare yet reduce energy use per tonne in some systems?
Mechanised farms are exempt from counting fuel in energy budgets
Machines produce energy as they work, offsetting their fuel use
Higher yields and timeliness raise output faster than energy inputs
Energy per tonne always falls whenever energy per hectare rises
Answer and working
C. Higher yields and timeliness raise output faster than energy inputs
If mechanisation and inputs raise yields more than proportionally, specific energy (MJ per kg) can fall. Machines consume rather than produce energy, fuel is counted, and the relation is not automatic.
Question 3 · medium
Which siting option for solar power avoids competition with farmland?
Floating solar on reservoirs and canal tops
Converting irrigated paddy land to solar parks
Removing orchards to install fixed-tilt arrays
Clearing forest to create flat land for panels
Answer and working
A. Floating solar on reservoirs and canal tops
Floating, canal-top and rooftop solar use no new land; clearing forests or converting productive farmland increases competition and impacts.
Question 4 · medium
In the usual order of decarbonising energy use, what comes first?
Buying carbon offsets for all fuel use
Improving efficiency to cut the energy needed
Building new fossil generation for reliability
Switching to hydrogen for every machine
Answer and working
B. Improving efficiency to cut the energy needed
Efficiency first reduces the energy that must then be electrified and supplied from low-carbon sources. Offsets do not cut emissions; hydrogen is for hard-to-electrify uses.
Question 5 · hard
Why do MACCs often overstate the uptake of 'negative-cost' efficiency measures?
They hide barriers such as capital, information and split incentives
They assume carbon prices of zero, which makes all measures expensive
They count only renewable energy and ignore efficiency entirely
They include measures that have already been fully adopted everywhere
Answer and working
A. They hide barriers such as capital, information and split incentives
Negative-cost measures remain unadopted because of capital constraints, transaction costs, landlord–tenant split incentives and behaviour that MACCs do not show.
Question 6 · medium
Which enabler helps farmers adopt electric and solar equipment despite high upfront costs?
Removing all rural grid upgrades to encourage off-grid use
Raising grid electricity tariffs only for small farmers
Leasing, pay-as-you-go and service-provider models that spread costs
Requiring farmers to pay the full cost in cash before delivery
Answer and working
C. Leasing, pay-as-you-go and service-provider models that spread costs
Finance and service models (leasing, pay-as-you-go, cooperatives, custom hiring) reduce the upfront barrier. The other measures add barriers.
Question 7 · hard
A solar park is proposed on land used by tenant farmers and pastoralists. Which approach best reflects just-transition principles?
Proceeding without consultation because renewable energy is always beneficial
Compensating only registered landowners and excluding tenants and herders
Consultation, consent and benefit-sharing with all land users
Relocating all users without compensation to speed up construction
Answer and working
C. Consultation, consent and benefit-sharing with all land users
Just transition requires participation, consent and fair benefit-sharing, including for tenants and pastoralists who lack formal title. Excluding or displacing them without consent is unjust.
A study plan for Energy, Environment & Agri-energy Transitions in GARP Sustainability and Climate Risk Certificate
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (56% of the 16 questions): Electrification and decarbonisation pathways for farms (4, 25%); Just transition in energy (3, 19%); Agrivoltaics and land competition (2, 13%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Energy use in agriculture and food systems (2, 13%); Global energy resources and reserves (2, 13%); Bioenergy sustainability: land use, food-versus-fuel, carbon debt (1, 6%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Renewable and non-renewable sources and their impacts (1, 6%); The energy-environment nexus (1, 6%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Energy use in agriculture and food systems (1 hard of 2), Global energy resources and reserves (1 hard of 2), Just transition in energy (1 hard of 3).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.