ICAR AIEEA-PG Dairy Effluent Treatment & Environmental Management: practice questions
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
48written to this exam in this subject
11syllabus units
About ICAR AIEEA-PG
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Dairy Effluent Treatment & Environmental Management in ICAR AIEEA-PG
Characterising and treating dairy wastewater, sludge and emissions, and measuring the environmental footprint of milk.
Our 48 ICAR AIEEA-PG questions in this subject: 17 easy, 31 medium, 0 hard, across 11 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
Question 1 · medium
A sample is diluted 1 in 50 (fraction 0.02). Dissolved oxygen falls from 8.5 to 4.1 mg/L during incubation. What is the BOD?
220 mg/L
425 mg/L
0.09 mg/L
205 mg/L
Answer and working
A. 220 mg/L
BOD = (8.5 − 4.1) ÷ 0.02 = 220 mg/L. 425 uses the initial DO alone; 205 uses the final DO alone.
Question 2 · easy
A reactor's influent COD is 4,000 mg/L and its effluent COD is 800 mg/L. What is the COD removal?
3,200%
5%
20%
80%
Answer and working
D. 80%
(4,000 − 800) ÷ 4,000 = 80%.
Question 3 · medium
A process emits 10 kg of methane (GWP 27) and 1 kg of nitrous oxide (GWP 273). What is the total in CO₂e?
543 kg
2,973 kg
300 kg
11 kg
Answer and working
A. 543 kg
270 + 273 = 543 kg CO₂e.
Question 4 · medium
Which oxidant is used in the standard COD test?
Hydrogen peroxide
Potassium permanganate at room temperature
Ozone
Potassium dichromate
Answer and working
D. Potassium dichromate
Dichromate in hot sulphuric acid with silver sulphate catalyst.
Question 5 · medium
Why is COD preferred to BOD for daily process control?
It needs no reagents
Results in hours
It is legally required daily
It measures only biodegradable matter
Answer and working
B. Results in hours
COD takes 2–3 hours, BOD days.
Question 6 · medium
Why is dissolved air flotation favoured over primary settling for dairy effluent?
DAF removes nitrate
Settling tanks cannot be built on most dairy sites
DAF needs no chemicals
Fat floats, fine flocs settle poorly
Answer and working
D. Fat floats, fine flocs settle poorly
Flotation exploits the low density of fat and fine protein flocs.
Question 7 · medium
What does a high sludge volume index indicate?
Low oxygen demand
High pH
Bulking
Excellent settling
Answer and working
C. Bulking
High SVI means sludge occupies a large volume per gram and settles poorly.
Question 8 · medium
What is a sequencing batch reactor?
One tank cycling fill, react, settle and decant
A sand filter
A series of shallow lagoons with no mechanical aeration
An anaerobic filter
Answer and working
A. One tank cycling fill, react, settle and decant
Timed cycles in one tank suit variable dairy flows.
Question 9 · medium
Which is an advantage of anaerobic over aerobic treatment?
Better nutrient removal
Faster start-up
Less sensitivity to shock loads and toxins
Less sludge and energy recovery
Answer and working
D. Less sludge and energy recovery
Most carbon becomes biogas; there is no aeration energy.
Question 10 · easy
What is 'cow water'?
Washwater from cow sheds and milking parlours
Water from the farm well
Condensate from evaporating milk
Water given to cows
Answer and working
C. Condensate from evaporating milk
Vapour from milk or whey concentration is condensed as cow water.
A study plan for Dairy Effluent Treatment & Environmental Management in ICAR AIEEA-PG
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (56% of the 48 questions): BOD, COD, fats-oil-grease and nutrient measurement (10, 21%); Aerobic treatment: activated sludge and its variants (6, 13%); Anaerobic treatment and biogas (6, 13%); Life-cycle assessment and carbon footprint of dairy products (5, 10%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Sources and characteristics of dairy effluent (5, 10%); Nutrient removal and tertiary treatment (4, 8%); Preliminary and primary treatment: screening, equalisation, dissolved air flotation (4, 8%); Water recovery from cow water and condensate (3, 6%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Discharge standards and permits (2, 4%); Sludge handling and disposal (2, 4%); Environmental management systems: ISO 14001 (1, 2%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Bank the easy marks: Environmental management systems: ISO 14001 (1 easy of 1); Preliminary and primary treatment: screening, equalisation, dissolved air flotation (2 easy of 4).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.