FSSAI Food Analyst Examination (and Junior Analyst Examination) · India · Food Safety and Standards Authority of India
Original practice questions written to the published syllabus · not past papersFSSAI Food Analyst Examination (and Junior Analyst Examination) is a licensing and registration exam run by Food Safety and Standards Authority of India, for candidates in India. A computer-based multiple-choice test in either the Chemical or the Biological discipline (+4 for a correct answer, -1 for a wrong one, 50% to qualify), then a practical examination, document verification and two weeks of compulsory training (11th Food Analyst Examination, FSSAI).
Source: sites.fssai.gov.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
This exam row is not yet verified in Laisha's map, but qualifying examinations for food analysts centre on exactly this subject: sampling and legal procedures, proximate analysis calculations (moisture, ash, acid-insoluble ash, Kjeldahl protein, fat by Gerber and Soxhlet, sugars by Lane–Eynon), oil constants, titratable acidity, instrumental principles (AAS, ICP, GC, HPLC, ELISA) and method validation and laboratory quality systems. Practical examinations test the same methods at the bench.
How a food laboratory measures what is in a food: sampling, proximate analysis, official methods, and the instruments — spectroscopy, chromatography, mass spectrometry and electrophoresis — that a food analyst runs. It is the core of the food analyst qualification in countries that license analysts.
Our 53 FSSAI Food Analyst Examination questions in this subject: 16 easy, 27 medium, 10 hard, across 15 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to FSSAI Food Analyst Examination and are not shown on any other exam's page.
In the Codex classification of methods, a Type I (defining) method is one that
D. defines a value obtainable only by that method
Type I defines the value (e.g. some empirical methods); Type II is reference; Type III alternative approved; Type IV tentative.
Many regulators now set performance criteria rather than prescribing one method. This means a laboratory may use
A. any method shown to meet the criteria
Performance-based approaches require evidence that the method meets trueness, precision, LOD and LOQ criteria.
A 5.000 g sample weighs 4.350 g after oven drying. Its moisture content is
D. 13.0 %
(5.000 − 4.350)/5.000 × 100 = 13.0 %. 87.0 % is total solids; 15.0 % divides by the dry mass; 6.5 % is a decimal slip.
The specific nitrogen-to-protein factor commonly used for milk and dairy products is
D. 6.38
6.38 for milk; 5.7 for wheat; 5.46 for peanuts; 6.25 is the general factor.
The Röse–Gottlieb (Mojonnier) method for fat in milk uses
C. ammonia, ethanol and ethers
Ammonia dissolves casein, ethanol aids separation, and diethyl and petroleum ethers extract fat gravimetrically.
In the Lane–Eynon method for reducing sugars, the indicator is
C. methylene blue
Methylene blue is decolorised when all copper in Fehling's solution has been reduced at boiling.
Microbiological assays are still used for folate and vitamin B12 because they
B. measure biologically active forms with high sensitivity
Growth of vitamin-dependent bacteria responds to active vitamers; they are slow but sensitive.
10 g of orange juice requires 12.0 mL of 0.1 N NaOH to the phenolphthalein end-point. Titratable acidity as citric acid (meq wt 0.064 g) is
A. 0.768 %
TA = 12.0 × 0.1 × 0.064 × 100/10 = 0.768 %. 0.077 % omits the ×100/mass; 1.080 % uses lactic acid; the last inverts the mass factor.
A pH meter for acid foods is calibrated with
D. two buffers bracketing the sample, such as pH 4 and 7
Two-point calibration bracketing the expected pH sets slope and offset.
In a proficiency test, a laboratory reports 54 mg/kg; the assigned value is 50 mg/kg and the standard deviation for proficiency 2.5 mg/kg. Its z-score and its classification are
C. 1.6, questionable
z = (54 − 50)/2.5 = 1.6; 2 < |z| < 3 is questionable. 4.0 omits the standard deviation; 0.6 inverts the ratio.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.