Original practice questions written to the published syllabus · not past papersFSSAI Food Analyst Examination (and Junior Analyst Examination) is a licensing and registration exam run by Food Safety and Standards Authority of India, for candidates in India. A computer-based multiple-choice test in either the Chemical or the Biological discipline (+4 for a correct answer, -1 for a wrong one, 50% to qualify), then a practical examination, document verification and two weeks of compulsory training (11th Food Analyst Examination, FSSAI).
Source: sites.fssai.gov.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Controlling quality in the plant and in the laboratory: quality systems and TQM, control charts and process capability, acceptance sampling and two- and three-class sampling plans, laboratory quality management and ISO/IEC 17025 accreditation, method validation and proficiency testing.
Our 39 FSSAI Food Analyst Examination questions in this subject: 10 easy, 27 medium, 2 hard, across 8 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to FSSAI Food Analyst Examination and are not shown on any other exam's page.
For the same plan (n = 5, c = 2, m = 10², M = 10³ cfu/g), one unit gives 2000 cfu/g and the others are below 100. What is the decision?
B. Reject: one unit exceeds M
Any unit above M makes the lot unacceptable regardless of c. Averaging or retesting to replace a result is not permitted by the plan.
Why is chain-of-custody documentation essential for official food samples?
C. It proves who held the sample and when
Legal samples must be shown to be the sample taken, unaltered; custody records track every transfer. Price, validation and duplicates are separate matters.
What is the purpose of a reagent blank in a chemical analysis batch?
C. To detect contamination or interference from reagents
A blank carried through the procedure without sample shows contribution from reagents, glassware and environment. Recovery uses spikes; balances are calibrated with weights; duplicates check precision.
What reproducibility RSD does the Horwitz equation predict for an analyte at 1 mg/kg (mass fraction 10⁻⁶)?
B. 16%
RSD_R = 2^(1 − 0.5 log₁₀C) = 2^(1 + 3) = 16%. 4% is the prediction at 1% (C = 0.01); 45% at 1 µg/kg; 8% at about 0.1%.
A 100 mL volumetric flask has a stated tolerance of ±0.08 mL with no further information. What is the standard uncertainty from the tolerance?
C. 0.046 mL
With a rectangular distribution, u = a/√3 = 0.08/1.732 = 0.046 mL. 0.080 uses the half-width directly; 0.040 divides by 2; 0.033 divides by √6 (triangular).
A contaminant has a legal limit of 10 µg/kg. A laboratory reports 11.5 ± 2.0 µg/kg (k = 2). Under the rule "non-compliant if result − U exceeds the limit", what is the decision?
A. Not shown to be non-compliant
11.5 − 2.0 = 9.5, which is not above 10, so non-compliance is not established beyond reasonable doubt under this rule; but neither is compliance proved, since 11.5 + 2.0 exceeds the limit. Retesting until a convenient result appears is not valid.
A mass is obtained by difference of two weighings with standard uncertainties 0.03 g and 0.04 g. What is the standard uncertainty of the difference?
B. 0.05 g
For sums and differences, absolute uncertainties combine in quadrature: √(0.03² + 0.04²) = 0.05 g. 0.01 subtracts them; 0.07 adds them; 0.0025 is the variance, not its square root.
To which standard are producers of reference materials accredited?
A. ISO 17034
ISO 17034 covers reference-material producers; ISO/IEC 17043 covers proficiency-testing providers; ISO/IEC 17020 inspection bodies; ISO 19011 is audit guidance.
Which Codex guideline recommends accreditation, proficiency testing, validated methods and internal QC for laboratories involved in import and export control of foods?
A. CXG 27-1997
CXG 27-1997 covers assessment of the competence of testing laboratories involved in import and export control. CXG 50-2004 is on sampling, CXG 21-1997 on microbiological criteria and CXC 1-1969 on food hygiene.
How does accreditation differ from certification?
B. Accreditation: competence; certification: conformity
Accreditation (by a body under ISO/IEC 17011) recognises competence of conformity-assessment bodies such as labs; certification (by a certification body) attests that a system, product or person conforms to requirements. Either may be voluntary or required depending on the context.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |