ICAR AIEEA-PG Dairy Refrigeration & Cold Chain: practice questions
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
23written to this exam in this subject
12syllabus units
About ICAR AIEEA-PG
ICAR AIEEA-PG: Dairy Science (group 16) and Dairy Technology (group 17) is a postgraduate admission exam run by NTA for ICAR, for candidates in India. Computer-based, 2 hours, 120 multiple-choice questions, +4 for a correct answer and −1 for a wrong one (2026 bulletin). One paper per major subject group.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Dairy Refrigeration & Cold Chain in ICAR AIEEA-PG
Unit III: refrigeration and air conditioning, artificial refrigeration, compression systems, refrigeration accessories, and calculation of the size of a refrigeration machine.
Refrigeration systems, ice-bank and chilled-water plants, cold stores and the cold chain from farm to retail. The agricultural engineering track (refrigeration-cold-chain) gives the general theory.
Our 23 ICAR AIEEA-PG questions in this subject: 21 easy, 2 medium, 0 hard, across 12 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
Question 1 · medium
What is the Carnot COP for refrigeration with evaporation at −10 °C and condensation at 35 °C?
5.85
6.85
3.50
0.22
Answer and working
A. 5.85
COP = 263.15 ÷ (308.15 − 263.15) = 5.85. 0.22 uses Celsius; 6.85 is the heat-pump Carnot COP; 3.50 is a meaningless ratio of Celsius values.
Question 2 · easy
A cold store's calculated load is 50 kW. With a 10% safety factor, what capacity is specified?
45 kW
60 kW
50 kW
55 kW
Answer and working
D. 55 kW
50 × 1.1 = 55 kW; 50 kW has no margin and 60 kW uses 20%.
Question 3 · easy
Why is the refrigerant vapour superheated slightly before entering the compressor?
To lower compressor power to zero
Protect the compressor
To raise the condensing pressure
To increase the refrigerant charge
Answer and working
B. Protect the compressor
Liquid slugging damages compressors.
Question 4 · easy
Which compressor type dominates large dairy ammonia plants?
Diaphragm
Scroll
Capillary
Screw
Answer and working
D. Screw
Screw compressors handle large volumes efficiently.
Question 5 · easy
The main purpose of a bulk milk cooler is to:
Separate cream
Ferment milk
Pasteurise milk on the farm before sale
Cool milk quickly after milking
Answer and working
D. Cool milk quickly after milking
Prompt cooling preserves raw milk quality.
Question 6 · easy
Hardening tunnels for ice cream typically use air at about:
Thicker insulation of the same material makes heat gain:
Negative
Larger
Unchanged
Smaller
Answer and working
D. Smaller
Heat flow falls as thickness rises, since U ≈ k ÷ thickness.
A study plan for Dairy Refrigeration & Cold Chain in ICAR AIEEA-PG
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (52% of the 23 questions): Vapour compression cycle and coefficient of performance (5, 22%); Bulk milk coolers (3, 13%); Cooling load calculation for cold stores (2, 9%); Hardening rooms and frozen storage (2, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Insulation and vapour barriers (2, 9%); Multi-pressure and ammonia systems (2, 9%); Psychrometry and air conditioning (2, 9%); Compressors, condensers, evaporators and expansion devices (1, 4%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Ice-bank and chilled-water systems (1, 4%); Refrigerants and their environmental rules (1, 4%); Refrigerated transport and cold-chain monitoring (1, 4%); Vapour absorption refrigeration and heat pumps (1, 4%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Bank the easy marks: Cooling load calculation for cold stores (2 easy of 2); Hardening rooms and frozen storage (2 easy of 2).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.