ICAR AICE-JRF/SRF Environmental Monitoring & Instrumental Analysis: practice questions
ICAR AICE-JRF/SRF (PhD) — Environmental Sciences (subject 71) and Agricultural Meteorology (subject 60) · India · National Testing Agency for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
50written to this exam in this subject
11syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD) — Environmental Sciences (subject 71) and Agricultural Meteorology (subject 60) is a PhD, fellowship and lectureship exam run by National Testing Agency for ICAR, for candidates in India. Computer-based MCQ paper for PhD admission and the JRF/SRF fellowship; one paper per subject. Timing and marking follow the yearly bulletin and were not re-read.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Environmental Monitoring & Instrumental Analysis in ICAR AICE-JRF/SRF
Monitoring design, water and sediment sampling, analytical instrumentation, bioindicators and biomonitoring of aquatic ecosystems, toxicity testing and quality assurance.
How environmental samples are taken and analysed and how good the numbers are: sampling plans, gravimetric and volumetric methods, spectroscopy, chromatography, quality assurance and monitoring networks.
Our 50 ICAR AICE-JRF/SRF questions in this subject: 1 easy, 28 medium, 21 hard, across 11 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · hard
Which non-parametric test is widely used to detect monotonic trends in environmental time series?
Student's paired t-test
Mann–Kendall test
Chi-square goodness-of-fit test
Tukey's post-hoc test
Answer and working
B. Mann–Kendall test
Mann–Kendall detects monotonic trends without assuming normality; the others serve different purposes.
Question 2 · medium
What is the equation of Craig's global meteoric water line?
δ18O = 8δ2H + 10
δ2H = 10δ18O + 8
δ2H = 8δ18O + 10
δ2H = δ18O
Answer and working
C. δ2H = 8δ18O + 10
Precipitation worldwide plots near δ2H = 8δ18O + 10.
Question 3 · hard
Which radionuclide pair is used to date lake sediments deposited over the last century or so?
Uranium-238 with thorium-232
Lead-210 with caesium-137 markers
Tritium with radon-222
Carbon-14 with potassium-40
Answer and working
B. Lead-210 with caesium-137 markers
210Pb (t½ ~22 yr) gives ages over ~100–150 years; 137Cs peaks (1963, 1986) provide independent markers.
Question 4 · medium
Why does 14C measurement distinguish fossil from modern carbon?
Its 14C has decayed away
Modern carbon contains no 14C
14C occurs only in limestone
Fossil carbon is enriched in 14C by heat
Answer and working
A. Its 14C has decayed away
Fossil fuels are millions of years old, so 14C is absent; living carbon contains atmospheric 14C.
Question 5 · medium
How should a result below the limit of detection be reported?
As exactly zero
As the LOD value as if detected
It should be deleted from the dataset
As not detected below the limit
Answer and working
D. As not detected below the limit
Reporting '< LOD' preserves information about the method's sensitivity.
Question 6 · hard
Why is a high correlation coefficient (such as r² = 0.999) not sufficient proof of a good calibration?
Curvature or bias hides behind a high r²
High r² always indicates contamination of standards
Calibration only needs a single standard
r² is meaningless for any straight line
Answer and working
A. Curvature or bias hides behind a high r²
Systematic patterns in residuals and independent check standards reveal non-linearity and errors hidden by r².
Question 7 · medium
On a Shewhart control chart, action limits are usually set at
±10 per cent of the mean
±3 standard deviations
±1 standard deviation
±0.5 standard deviations
Answer and working
B. ±3 standard deviations
Warning limits ±2σ, action limits ±3σ.
Question 8 · medium
An effluent has a 96-hour LC50 of 25 per cent. How many toxic units does it have (TU = 100/LC50)?
4
0.25
25
75
Answer and working
A. 4
TU = 100/25 = 4; higher TU means greater toxicity.
Question 9 · medium
Who developed the fish index of biotic integrity (IBI) in 1981?
Charles Elton
Rachel Carson
Robert Paine
James Karr
Answer and working
D. James Karr
Karr's IBI combines fish community metrics; Paine studied keystone species.
Question 10 · hard
Vitellogenin found in male fish indicates exposure to
high water temperature
low dissolved oxygen
suspended sediment
oestrogenic endocrine-disrupting compounds
Answer and working
D. oestrogenic endocrine-disrupting compounds
Vitellogenin is an egg-yolk precursor normally made by females; its induction in males signals oestrogen mimics.
A study plan for Environmental Monitoring & Instrumental Analysis in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (52% of the 50 questions): Bioindicators and biomonitoring (8, 16%); Detection limits, accuracy, precision and calibration (7, 14%); Stable and radioactive isotopes in environmental analysis (6, 12%); Continuous and low-cost sensor monitoring (5, 10%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Gas and liquid chromatography; mass spectrometry (5, 10%); Quality assurance, quality control and laboratory accreditation (5, 10%); Monitoring objectives and network design (4, 8%); Atomic absorption and ICP techniques (3, 6%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Electrochemical methods and sensors (3, 6%); UV-visible spectrophotometry and colorimetry (3, 6%); Sampling and preservation of water, soil, air and biota (1, 2%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Sampling and preservation of water, soil, air and biota (1 hard of 1), Atomic absorption and ICP techniques (2 hard of 3), Electrochemical methods and sensors (2 hard of 3).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Bioindicators and biomonitoring (1 easy of 8).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.