GATE ES Air & Noise Pollution: Monitoring & Control: practice questions
GATE — Environmental Science and Engineering (ES) · India · IITs and IISc on rotation (2027: IIT Madras)
Original practice questions written to the published syllabus · not past papers
10worked here, free
89written to this exam in this subject
13syllabus units
About GATE ES
GATE — Environmental Science and Engineering (ES) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 subject). MCQ, MSQ and NAT question types with negative marking on MCQ only, as in all GATE papers.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Air & Noise Pollution: Monitoring & Control in GATE ES
Air pollutants, their health and crop effects, standards and indices, dispersion, and control equipment, plus noise. Agricultural sources (residue burning, ammonia, dust, odour) are covered here alongside the industrial ones GATE ES examines.
Our 89 GATE ES questions in this subject: 16 easy, 51 medium, 22 hard, across 13 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE ES and are not shown on any other exam's page.
Question 1 · hard
Why is airshed or regional management increasingly advocated over city-by-city control?
Cities have no local sources of air pollution at all
Pollutants never travel more than a kilometre from their source
Much of a city's PM2.5 comes from outside it
Regional management removes the need for any emission standards
Answer and working
C. Much of a city's PM2.5 comes from outside it
Long-range transport and secondary formation mean regional sources contribute substantially, so coordinated action is needed.
Question 2 · easy
According to India's NAAQS (2009), what is the 24-hour standard for PM2.5?
40 µg/m³
60 µg/m³
100 µg/m³
15 µg/m³
Answer and working
B. 60 µg/m³
PM2.5: 40 annual, 60 24-hour. 100 is the PM10 24-hour standard; 15 is the WHO 2021 24-hour guideline.
Question 3 · medium
What is the WHO 2021 annual Air Quality Guideline for PM2.5?
25 µg/m³
40 µg/m³
5 µg/m³
10 µg/m³
Answer and working
C. 5 µg/m³
WHO lowered the annual PM2.5 guideline from 10 (2005) to 5 µg/m³ in 2021; India's NAAQS is 40.
Question 4 · medium
Which source dominates global atmospheric ammonia emissions?
Agriculture, mainly livestock manure and fertilisers
Vehicle exhausts
Volcanoes
Coal-fired power stations
Answer and working
A. Agriculture, mainly livestock manure and fertilisers
Agriculture contributes the large majority of NH3 emissions.
Question 5 · medium
Which formula has been used in India to set minimum stack height from SO2 emission rate Q (kg/h)?
H = 14 + Q
H = 0.3Q^14
H = 14Q^0.3
H = Q/14
Answer and working
C. H = 14Q^0.3
CPCB guidelines used H = 14Q^0.3 metres, with a minimum height for many industries.
Question 6 · easy
Activated carbon is mainly used to control which emissions?
Noise from machinery
Carbon monoxide from cars
Coarse dust particles
Volatile organic compounds and odours
Answer and working
D. Volatile organic compounds and odours
Activated carbon adsorbs VOCs and odours; dust needs particulate collectors; CO needs oxidation.
Question 7 · medium
What is 'breakthrough' in a fixed-bed adsorber?
When outlet concentration starts to rise
The point when pressure drop falls to zero
The time when gas first enters the bed
The moment the bed catches fire
Answer and working
A. When outlet concentration starts to rise
As the mass transfer zone reaches the outlet, pollutant appears in the effluent and the bed must be regenerated.
Question 8 · hard
Why are biofilters suited to treating odours from composting and livestock buildings?
They condense odours into liquid fuel
They burn odours at high temperature
They adsorb odours permanently without any microbial activity
Microbes cheaply degrade dilute soluble odorants
Answer and working
D. Microbes cheaply degrade dilute soluble odorants
Moist media host microbes that oxidise compounds such as H2S, ammonia and VFAs at low cost for large dilute flows.
Question 9 · medium
In wet limestone flue gas desulphurisation, the main by-product is
sodium sulphate
gypsum, calcium sulphate
elemental sulphur
sulphuric acid
Answer and working
B. gypsum, calcium sulphate
SO2 reacts with limestone and is oxidised to gypsum, usable in wallboard and cement.
Question 10 · hard
With a 3 dB exchange rate and a limit of 85 dB(A) for 8 hours, how long may a worker be exposed to 91 dB(A)?
4 hours
8 hours
1 hour
2 hours
Answer and working
D. 2 hours
Each 3 dB halves the time: 88 dB → 4 h, 91 dB → 2 h.
A study plan for Air & Noise Pollution: Monitoring & Control in GATE ES
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (48% of the 89 questions): Noise: sources, effects, standards, measurement and control (10, 11%); Particulate control: settling chambers, cyclones, wet scrubbers, fabric filters, ESP (9, 10%); Control of SOx, NOx, CO and hydrocarbons; vehicle emissions (8, 9%); Emission inventories for point, line and area sources (8, 9%); Gaseous control: absorption, adsorption, condensation, combustion (8, 9%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Gaussian plume dispersion modelling (8, 9%); Meteorology and dispersion: stability, mixing height, wind rose (8, 9%); Criteria pollutants, ambient and emission standards (7, 8%); Indoor air pollution (6, 7%); Air quality indices and visibility (5, 6%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Effects on human health, crops and materials (5, 6%); Sources and classification of air pollutants; primary and secondary (5, 6%); Agricultural air pollution: residue burning, ammonia, dust and odour (2, 2%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Effects on human health, crops and materials (2 hard of 5), Gaussian plume dispersion modelling (3 hard of 8), Particulate control: settling chambers, cyclones, wet scrubbers, fabric filters, ESP (3 hard of 9).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Criteria pollutants, ambient and emission standards (2 easy of 7); Emission inventories for point, line and area sources (2 easy of 8).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.