LAISHA
Open Laisha

Farm Machinery Training & Testing Institutes Hydraulic Drives & Controls: practice questions

Farm Machinery Training & Testing Institutes (Budni, Hisar, Anantapur, Biswanath Chariali) · India · Ministry of Agriculture & Farmers Welfare, Government of India

Original practice questions written to the published syllabus · not past papers
10worked here, free
41written to this exam in this subject
9syllabus units

About Farm Machinery Training & Testing Institutes

Farm Machinery Training & Testing Institutes (Budni, Hisar, Anantapur, Biswanath Chariali) is a professional certification run by Ministry of Agriculture & Farmers Welfare, Government of India, for candidates in India. Not an exam: short training courses and machinery testing (commercial, batch, confidential, CMVR).

Official site: nerfmtti.nic.in.

We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.

Hydraulic Drives & Controls in Farm Machinery Training & Testing Institutes

Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.

Our 41 Farm Machinery Training & Testing Institutes questions in this subject: 17 easy, 20 medium, 4 hard, across 9 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to Farm Machinery Training & Testing Institutes and are not shown on any other exam's page.

Question 1 · medium

On a mobile machine, why is a fine filter normally placed in the return line rather than in the pump suction line?

  1. Return oil is cleaner, so a return filter lasts much longer than one on the suction side
  2. Suction-line filters are prohibited on mobile machines by the ISO 4406 cleanliness standard
  3. A fine element in the suction line could restrict inlet flow and cause pump cavitation
  4. Oil in the return line is hot, and fine filter media only work at high oil temperature
Answer and working

C. A fine element in the suction line could restrict inlet flow and cause pump cavitation

The pump inlet must stay above its minimum absolute pressure; a fine element, especially with cold oil or as it loads with dirt, would starve the pump, so suction lines carry only coarse strainers. Return oil is the dirtiest because it carries wear debris; ISO 4406 is a cleanliness code, not an installation rule; and filter media work at any normal temperature.

Question 2 · easy

A mechanic receives a pinhole-leak jet of hydraulic oil into a finger. The wound looks like a tiny puncture and hurts little. The correct action is to

  1. wash it, apply a plaster and watch it for signs of infection over a few days
  2. squeeze out the oil, disinfect the puncture and carry on working with gloves
  3. cool it under running water for twenty minutes as for a minor thermal burn
  4. treat it as a surgical emergency and get immediate specialist medical care
Answer and working

D. treat it as a surgical emergency and get immediate specialist medical care

High-pressure injection drives oil deep into tissue along tendon sheaths; the small entry wound hides serious damage, and delay risks loss of the finger. It needs urgent surgical assessment. Home wound care, squeezing or cooling do not remove injected oil. Leaks should be searched for with card or wood, never the hand.

Question 3 · hard

A tractor pump flow test gives 58 L/min at 10 bar and 46 L/min at rated pressure, with the oil at normal working temperature. The rated flow at that speed is 60 L/min. The most reasonable interpretation is that

  1. high internal leakage at pressure, showing a worn pump with ηv near 0.77
  2. the pump is healthy, because the flow at 10 bar is within a few per cent of the rated value
  3. the relief valve is set too low, because flow falls as pressure rises in every healthy pump
  4. the suction strainer is blocked, because a blockage reduces flow only when pressure is high
Answer and working

A. high internal leakage at pressure, showing a worn pump with ηv near 0.77

A positive-displacement pump's flow should fall only slightly with pressure. Here flow drops from 58 to 46 L/min, so ηv at rated pressure is 46/60 ≈ 0.77: internal leakage that rises with pressure is the signature of wear. A good low-pressure figure alone does not prove health. A low relief setting would cap pressure, not cut flow below it, and a suction blockage starves the pump at all pressures and causes cavitation noise.

Question 4 · medium

After fitting a replacement piston motor to a harvester's header drive, a mechanic plugs its case-drain port because no drain hose came with it. The likely result is

  1. case pressure builds with leakage oil until the shaft seal blows out
  2. the motor runs faster, because no oil is lost through the drain line
  3. nothing changes, because case drains are only needed for cold starts
  4. the motor runs in reverse, because leakage oil enters the outlet side
Answer and working

A. case pressure builds with leakage oil until the shaft seal blows out

Internal leakage collects in the motor case; if it cannot drain freely to tank, case pressure builds until the shaft seal, which is rated for low pressure, fails. Plugging the drain does not make leakage disappear or raise speed, and it does not change the direction of rotation.

Question 5 · medium

Two identical cylinders lift the two ends of a beam and are connected in parallel to one control valve. The beam load is heavier on the left. When the valve is opened,

  1. both cylinders extend together, because they are identical and share pressure
  2. the left cylinder extends first, because it receives the higher pressure
  3. neither moves until the pressure reaches the relief-valve setting
  4. the right cylinder, carrying the lighter load, extends first and the beam tilts
Answer and working

D. the right cylinder, carrying the lighter load, extends first and the beam tilts

Pressure rises only as far as the lightest load needs, so the lighter-loaded cylinder moves first and takes the flow; the other moves only when the first stops. Synchronising parallel cylinders needs a flow divider, mechanical tie or a series arrangement.

Question 6 · easy

Before a mechanic disconnects a line on a loader circuit fitted with a gas-charged accumulator for ride control, the accumulator must be discharged because

  1. its nitrogen precharge escapes into the oil whenever the engine stops
  2. it acts as a filter and releases trapped dirt if the line is opened
  3. it stores oil under pressure that is released even with the engine stopped
  4. it raises the oil temperature after shutdown and could scald hands
Answer and working

C. it stores oil under pressure that is released even with the engine stopped

A charged accumulator keeps oil at pressure after the pump stops, so opening a line can release a jet of oil or move the loader. The discharge procedure in the manual bleeds it to tank. The precharge gas is separated from the oil by a bladder, piston or diaphragm, and an accumulator is neither a filter nor a heater.

Question 7 · medium

On a combine whose hydraulic oil keeps running hot, an infrared thermometer shows one valve section much hotter than everything else. The most likely meaning is

  1. that valve section is too large for the circuit and is running at low velocity
  2. the oil in that section is cleaner than elsewhere and so carries more heat
  3. oil is passing through that section from high to low pressure without doing work
  4. the cooler is working too hard and has over-cooled every other component
Answer and working

C. oil is passing through that section from high to low pressure without doing work

Heat appears where pressure is dropped without useful work: a relief valve passing oil, a leaking spool or a worn seal. A local hot spot points to that component. A large valve with low velocity runs cool, cleanliness does not concentrate heat, and an efficient cooler would not make one section hotter.

Question 8 · easy

When ploughing with a mounted plough under draft control, the plough meets a patch of harder soil and its draft rises. The hydraulic system responds by

  1. lowering the plough deeper so that it cuts through the harder layer
  2. holding the plough at exactly the same height relative to the tractor
  3. raising the plough slightly to bring the draft back toward the set value
  4. releasing the plough to float freely on its own depth wheel
Answer and working

C. raising the plough slightly to bring the draft back toward the set value

Draft control holds the draft nearly constant: a rise in draft is sensed and the implement is raised slightly; when the draft falls it is lowered. Holding a fixed height is position control and floating on a wheel is float mode.

Question 9 · medium

A farmer complains that under draft control the ploughing depth varies noticeably across a field with patches of light and heavy soil. The setting that limits this variation while keeping some load control is

  1. float control, which lets the plough follow the ground surface on its own
  2. mixed or intermix control, which blends the draft and position signals
  3. a higher drop-rate setting, which makes the plough fall faster after lifting
  4. pure position control with the response set to maximum sensitivity
Answer and working

B. mixed or intermix control, which blends the draft and position signals

Intermix control combines both signals so depth changes are limited while the draft still influences the hitch. Float gives no hitch control; drop rate only affects lowering speed; pure position control holds depth but gives up draft sensing and its weight transfer.

Question 10 · medium

A tipping trailer uses a multi-stage telescopic cylinder. The main reason for this choice is that it

  1. produces equal force and equal speed in both directions of its stroke
  2. needs no seals at all because the nested stages are a close metal fit
  3. can be operated safely without a relief valve on the tractor side
  4. gives a long stroke from a short closed length under the body
Answer and working

D. gives a long stroke from a short closed length under the body

Nested stages give a stroke much longer than the closed length, which a tipping body needs. Equal force both ways is a double-rod cylinder; telescopic cylinders have seals on every stage; and every circuit still needs relief protection.

A study plan for Hydraulic Drives & Controls in Farm Machinery Training & Testing Institutes

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (54% of the 41 questions): Tractor hydraulic systems (11, 27%); Principles of fluid power (6, 15%); Hydraulic cylinders (5, 12%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Open-centre, closed-centre and load-sensing circuits (5, 12%); Hydraulic motors (4, 10%); Hydraulic pumps: gear, vane and piston (3, 7%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Pressure relief and flow control valves (3, 7%); Directional control valves (2, 5%); Pressure drop and heat generation (2, 5%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Hydraulic pumps: gear, vane and piston (2 hard of 3), Hydraulic cylinders (1 hard of 5), Tractor hydraulic systems (1 hard of 11).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Pressure relief and flow control valves (2 easy of 3); Open-centre, closed-centre and load-sensing circuits (3 easy of 5).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — Farm Machinery Training & Testing Institutes Hydraulic Drives & Controls

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files