NCEES PE Agricultural and Biological Engineering is a licensing and registration exam run by NCEES (ASABE is the content partner), for candidates in USA. Computer-based, 85 questions, 9.5-hour appointment (8.5 hours of exam). Once a year (next: 28 Oct 2026). Closed book with the electronic NCEES handbook and supplied searchable ASABE standards; SI and US customary units.

Source: ncees.org.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Hydraulic Drives & Controls in NCEES PE Agricultural and Biological Engineering

Explicit fluid-power content: pump and motor sizing from displacement, speed and efficiencies; cylinder force, speed and cycle time; hydraulic power and engine power required; pressure drop in lines and heat load; selecting valves and reading circuits drawn with standard symbols. Calculations dominate; unit consistency in psi, gpm, in³ and hp is tested.

Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.

Our 81 NCEES PE Agricultural and Biological Engineering questions in this subject: 16 easy, 44 medium, 21 hard, across 9 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to NCEES PE Agricultural and Biological Engineering and are not shown on any other exam's page.

Question 1 · easy

A hydraulic circuit delivers 60 L/min at a pressure of 180 bar. The hydraulic power is

  1. 1.8 kW
  2. 180 kW
  3. 1080 kW
  4. 18 kW
Answer and working

D. 18 kW

P = p × Q = 180 × 10⁵ Pa × (60/60000) m³/s = 18000 W = 18 kW, which is the shortcut p(bar) × Q(L/min)/600 = 180 × 60/600. Treating 180 bar as 180 MPa with the /60 shortcut gives 180 kW; leaving minutes unconverted gives 1080 kW; a factor-of-ten slip gives 1.8 kW.

Question 2 · medium

A pump delivers 20 US gal/min at 2500 psi. The hydraulic horsepower is closest to

  1. 21.8 hp
  2. 50.0 hp
  3. 2.9 hp
  4. 29.2 hp
Answer and working

D. 29.2 hp

Hydraulic horsepower = psi × gpm / 1714 = 2500 × 20 / 1714 = 29.2 hp. The value 21.8 is the same power in kilowatts written as horsepower; dividing by 1000 instead of 1714 gives 50.0; 2.9 is a decimal slip.

Question 3 · easy

The ISO viscosity grade (ISO VG) of an industrial hydraulic oil, such as VG 46, refers to

  1. its mid-point kinematic viscosity in mm²/s at 40 °C
  2. its dynamic viscosity in mPa·s measured at 100 °C
  3. the oil temperature in °C at which it reaches 46 cSt
  4. its viscosity index, a measure of change with temperature
Answer and working

A. its mid-point kinematic viscosity in mm²/s at 40 °C

ISO VG numbers are the mid-point kinematic viscosity in cSt (mm²/s) at 40 °C, within ±10 %. They are not dynamic viscosities, not temperatures and not viscosity indices; the viscosity index is a separate property describing how strongly viscosity changes with temperature.

Question 4 · easy

A gear pump has a displacement of 40 cm³/rev, runs at 1800 rev/min and has a volumetric efficiency of 92 %. Its actual delivery is

  1. 72.0 L/min
  2. 66.2 L/min
  3. 78.3 L/min
  4. 6.62 L/min
Answer and working

B. 66.2 L/min

Q = V × n × ηv = 40 cm³ × 1800 /min × 0.92 = 66240 cm³/min = 66.2 L/min. 72.0 L/min is the theoretical flow; dividing by ηv (78.3) treats the pump as a motor; 6.62 is a units slip.

Question 5 · medium

A double-acting cylinder has a 100 mm bore and a 50 mm rod. With 150 bar applied to the rod end, the retraction force is

  1. 117.8 kN
  2. 88.4 kN
  3. 29.5 kN
  4. 8.84 kN
Answer and working

B. 88.4 kN

Annulus area = π(0.1² − 0.05²)/4 = 5.890 × 10⁻³ m²; F = 150 × 10⁵ × 5.890 × 10⁻³ = 88.4 kN. The full piston area gives 117.8 kN (extension); the rod area gives 29.5 kN; 8.84 kN is a bar-to-pascal slip.

Question 6 · hard

A pump supplies 50 L/min to the rod end of a cylinder with a 100 mm bore and a 70 mm rod to retract it. The flow returning from the cap end to tank during retraction is

  1. 98.0 L/min
  2. 50.0 L/min
  3. 25.5 L/min
  4. 102.0 L/min
Answer and working

A. 98.0 L/min

Return flow = Q × Ap/Aa = 50 × (π0.1²/4)/(π(0.1² − 0.07²)/4) = 50 × 0.01/0.0051 = 98.0 L/min. The return line, valve and filter must handle this, almost double the pump flow. Assuming it equals pump flow gives 50.0; inverting the ratio gives 25.5; using the rod area gives 102.0.

Question 7 · medium

On an ISO 1219 directional valve symbol, what does each separate square in the row represent?

  1. One port of the valve, with its connection drawn on the outside edge
  2. One switching position of the valve, with its flow paths drawn inside
  3. One spool land of the valve, drawn to scale to show its relative width
  4. One flow rate the valve can deliver, from minimum on the left to maximum
Answer and working

B. One switching position of the valve, with its flow paths drawn inside

Each square (envelope) is one position; arrows inside show where oil flows and T-shaped marks show blocked ports in that position. Ports are drawn as lines on the outside of one square; squares do not represent lands or flow rates.

Question 8 · hard

Oil of 46 cSt flows at 60 L/min in a 20 mm bore line. The Reynolds number, and hence the flow regime, is

  1. about 1383956, turbulent
  2. about 5536, turbulent
  3. about 1384, laminar
  4. about 692, laminar
Answer and working

C. about 1384, laminar

v = (60/60000)/(π × 0.02²/4) = 3.18 m/s; Re = vD/ν = 3.18 × 0.020/46 × 10⁻⁶ = 1384, below about 2000, so laminar. Using 46 × 10⁻⁹ for cSt gives 1383956; using the radius instead of the diameter as the length in Re gives 692; 5536 comes from using the radius in the velocity area but the diameter in Re.

Question 9 · medium

Why does a hydraulic line carry a much higher pressure loss on a cold morning than at normal working temperature, for the same flow?

  1. Cold oil is much denser, and laminar friction loss is proportional to density squared
  2. Flow is laminar, so friction loss rises with viscosity, which is far higher when cold
  3. Cold oil is turbulent, and turbulent friction loss is independent of the oil's viscosity
  4. Hoses shrink in bore when cold, which halves the cross-sectional area of the line
Answer and working

B. Flow is laminar, so friction loss rises with viscosity, which is far higher when cold

With f = 64/Re in laminar flow, Δp = 32μLv/D², proportional to dynamic viscosity, which can rise many times at low temperature. Density changes little with temperature; cold, thick oil makes flow more laminar, not turbulent; and hose bores do not shrink appreciably.

Question 10 · hard

An engineer compares two ways of slowing a fixed-pump-driven hydraulic motor to half speed: (i) a meter-in flow control, and (ii) halving the engine speed. Assuming the same load torque, which statement is correct?

  1. Both waste the same power, because hydraulic losses depend only on the load torque
  2. Halving pump speed avoids the relief and throttling losses of the meter-in control
  3. The meter-in control is more efficient, because the pump still runs at its best speed
  4. Halving engine speed doubles the pressure, so it produces twice the heat of throttling
Answer and working

B. Halving pump speed avoids the relief and throttling losses of the meter-in control

With meter-in on a fixed pump, half the flow crosses the relief at full pressure and the rest is throttled down to load pressure, so a large fraction of pump power becomes heat. Reducing pump speed halves the flow with pressure set by the load, so little is throttled. Pressure is set by the load torque in both cases, not by pump speed.

A study plan for Hydraulic Drives & Controls in NCEES PE Agricultural and Biological Engineering

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (51% of the 81 questions): Pressure relief and flow control valves (16, 20%); Hydraulic cylinders (14, 17%); Pressure drop and heat generation (11, 14%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Directional control valves (9, 11%); Principles of fluid power (9, 11%); Hydraulic motors (8, 10%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Hydraulic pumps: gear, vane and piston (8, 10%); Open-centre, closed-centre and load-sensing circuits (4, 5%); Tractor hydraulic systems (2, 2%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Hydraulic cylinders (6 hard of 14), Hydraulic pumps: gear, vane and piston (3 hard of 8), Pressure relief and flow control valves (5 hard of 16).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Hydraulic motors (3 easy of 8); Principles of fluid power (3 easy of 9).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — NCEES PE Agricultural and Biological Engineering Hydraulic Drives & Controls

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.