About NCEES PE Agricultural and Biological Engineering

NCEES PE Agricultural and Biological Engineering is a licensing and registration exam run by NCEES (ASABE is the content partner), for candidates in USA. Computer-based, 85 questions, 9.5-hour appointment (8.5 hours of exam). Once a year (next: 28 Oct 2026). Closed book with the electronic NCEES handbook and supplied searchable ASABE standards; SI and US customary units.

Source: ncees.org.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Instrumentation, Sensors & Process Control in NCEES PE Agricultural and Biological Engineering

Applying sensors and data acquisition in system problems: flow measurement for irrigation and processing, environmental monitoring of animal and plant facilities, control strategies for dryers and ventilation.

Measuring temperature, pressure, flow, force and moisture, logging the data, and controlling processes automatically.

Our 45 NCEES PE Agricultural and Biological Engineering questions in this subject: 6 easy, 22 medium, 17 hard, across 11 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to NCEES PE Agricultural and Biological Engineering and are not shown on any other exam's page.

Question 1 · hard

PTO power is calculated as P = 2πNT/60. Torque T is measured to ±1.0% and shaft speed N to ±0.5%, independently. What is the most probable relative uncertainty in P?

  1. ±1.50%
  2. ±0.50%
  3. ±0.75%
  4. ±1.12%
Answer and working

D. ±1.12%

For a product of powers, relative uncertainties combine by root sum of squares (each exponent is 1): √(1.0² + 0.5²) = 1.12%. ±1.50% is the worst-case arithmetic sum; ±0.75% is the average; ±0.50% keeps only the smaller term.

Question 2 · medium

Dryer plenum air warms steadily at 2 °C per minute. The air-temperature sensor is first-order with a time constant of 30 s. Once the ramp is established, how far does the reading lag behind the true temperature?

  1. 60 °C
  2. 1.0 °C
  3. 2.0 °C
  4. 0.033 °C
Answer and working

B. 1.0 °C

For a ramp, a first-order sensor lags by rate × τ = (2 °C/60 s) × 30 s = 1.0 °C. 60 °C multiplies 2 by 30 without converting minutes to seconds; 2.0 °C would correspond to a 60 s time constant; 0.033 °C is the rate per second, not the lag.

Question 3 · medium

An infrared thermometer set to emissivity 0.95 is pointed at the bare polished stainless-steel outer wall of a hot-air duct and reads far below a contact thermocouple. What is the most likely cause?

  1. The polished metal has low emissivity, so it emits less than the 0.95 setting assumes
  2. The infrared thermometer is reading the air inside the duct through the thin steel wall
  3. The contact thermocouple is reading high because of its cold-junction compensation error
  4. Polished steel has a higher emissivity than 0.95, which makes infrared readings fall
Answer and working

A. The polished metal has low emissivity, so it emits less than the 0.95 setting assumes

Shiny metals have low emissivity (often well below 0.3), so with the instrument set to 0.95 it underestimates temperature, and it also picks up reflected radiation from the surroundings. The fix is high-emissivity tape or paint on the spot, or a contact measurement. Infrared does not see through steel.

Question 4 · easy

A turbine meter on a fertigation line has a K-factor of 50 pulses per litre. A counter records 1500 pulses in 60 s. What is the flow rate?

  1. 30 L/min
  2. 75 L/min
  3. 1.25 L/min
  4. 3000 L/min
Answer and working

A. 30 L/min

Volume = 1500/50 = 30 L in 60 s, i.e. 30 L/min (0.5 L/s). 75 L/min multiplies 1500 by 50 and divides by 1000; 3000 L/min multiplies the K-factor by the 60 s count period; 1.25 L/min takes the 75 L/min slip and divides it by 60 again.

Question 5 · hard

A TDR probe has 0.20 m rods. The two-way travel time of the pulse along the rods is 5.33 ns (c = 3×10⁸ m/s). Using the Topp equation, what is the volumetric water content?

  1. 0.467 m³/m³
  2. 0.291 m³/m³
  3. 0.689 m³/m³
  4. 0.055 m³/m³
Answer and working

B. 0.291 m³/m³

Ka = (c·t/2L)² = (3×10⁸ × 5.33×10⁻⁹ / 0.40)² = (3.998)² = 16.0. Topp: θv = −0.053 + 0.0292(16) − 5.5×10⁻⁴(256) + 4.3×10⁻⁶(4096) = 0.291. 0.467 keeps only the linear term; 0.689 treats 5.33 ns as a one-way time (Ka = 64); 0.055 forgets to square, using Ka = 4.

Question 6 · hard

Greenhouse air is at 25 °C and 70% relative humidity. Using es = 0.6108 exp(17.27T/(T+237.3)) kPa, what is the vapour pressure deficit?

  1. 0.95 kPa
  2. 2.22 kPa
  3. 3.17 kPa
  4. 0.30 kPa
Answer and working

A. 0.95 kPa

es(25 °C) = 0.6108 × exp(17.27 × 25/262.3) = 3.168 kPa; ea = 0.70 × 3.168 = 2.217 kPa; VPD = es − ea = 0.95 kPa. 2.22 kPa is the actual vapour pressure, 3.17 kPa the saturation value, and 0.30 is the RH deficit fraction without units of pressure.

Question 7 · hard

In a grain plant, the bucket elevator motor trips on overload while the intake conveyor and the bin-fill conveyor are running. What should the interlock logic do?

  1. Stop the bin-fill conveyor at once, and let the intake conveyor run on so that it clears the intake pit first
  2. Stop the intake conveyor feeding the elevator at once, and let the bin-fill conveyor run on to empty
  3. Keep all machines running and only sound an alarm until the operator inspects the elevator
  4. Restart the elevator automatically after a short delay so that throughput is not interrupted
Answer and working

B. Stop the intake conveyor feeding the elevator at once, and let the bin-fill conveyor run on to empty

Every machine feeding a stopped machine must stop, or grain piles up and chokes the elevator. Machines downstream can run on to empty. Automatic restart after an overload trip is unsafe; the cause must be found first.

Question 8 · medium

In an ultimate-cycle test on a dryer burner loop, sustained oscillation occurs at Ku = 8 with period Pu = 120 s. What are the Ziegler–Nichols PID settings?

  1. Kp = 3.6, Ti = 100 s, Td = 15 s
  2. Kp = 4.0, Ti = 60 s, Td = 30 s
  3. Kp = 4.8, Ti = 120 s, Td = 60 s
  4. Kp = 4.8, Ti = 60 s, Td = 15 s
Answer and working

D. Kp = 4.8, Ti = 60 s, Td = 15 s

Ziegler–Nichols PID: Kp = 0.6Ku = 4.8, Ti = Pu/2 = 60 s, Td = Pu/8 = 15 s. Kp = 3.6 with Ti = 100 s is the PI rule; 0.5Ku is the P-only rule. These settings give quarter-amplitude decay and are usually softened in practice.

Question 9 · medium

What is the main trade-off of a mesh topology compared with a star topology in a field sensor network?

  1. It removes the need for a gateway, but every node then needs a cellular subscription
  2. It extends coverage around obstacles, but relaying nodes use more energy and add latency
  3. It lowers every node's power use, but it can only cover a single greenhouse bay
  4. It doubles the data rate of each link, but it can only carry analog sensor values
Answer and working

B. It extends coverage around obstacles, but relaying nodes use more energy and add latency

In a mesh, nodes relay each other's packets, so the network can reach around obstacles and beyond one hop, at the cost of extra listening and transmitting energy on relaying nodes, and more complex routing. A star needs every node in direct range of the gateway.

Question 10 · hard

An automated irrigation system starts a pump whenever one soil-moisture node reports a value below threshold. One night the node's probe is pulled partly out of the soil by a rodent and the pump runs for 10 hours. What design change best prevents this?

  1. Replace the probe with a more expensive model, which will never give an implausible or out-of-range reading
  2. Shorten the logging interval so the controller receives more of the same faulty readings
  3. Remove the threshold so that the pump runs on a fixed timer as well as on sensor demand
  4. Cross-check against other sensors or a water-balance model, flag sudden steps, and cap run time
Answer and working

D. Cross-check against other sensors or a water-balance model, flag sudden steps, and cap run time

No sensor is immune to physical failure. Automated decisions should check plausibility (sudden steps, out-of-range values), agree with redundant sensors or a model, and have hard limits such as maximum run time and flow-meter confirmation. More frequent faulty readings do not help.

A study plan for Instrumentation, Sensors & Process Control in NCEES PE Agricultural and Biological Engineering

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (58% of the 45 questions): IoT sensor networks (9, 20%); Control modes: on-off, P, PI and PID (6, 13%); Moisture measurement (6, 13%); Data acquisition and data loggers (5, 11%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Pressure, flow and level measurement (5, 11%); Programmable logic controllers (4, 9%); Force, torque and strain: strain gauges and load cells (3, 7%); Signal conditioning (3, 7%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: The generalised measurement system (2, 4%); Static and dynamic characteristics of instruments (1, 2%); Temperature transducers (1, 2%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: The generalised measurement system (2 hard of 2), Control modes: on-off, P, PI and PID (3 hard of 6), Moisture measurement (3 hard of 6).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: IoT sensor networks (3 easy of 9); Force, torque and strain: strain gauges and load cells (1 easy of 3).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — NCEES PE Agricultural and Biological Engineering Instrumentation, Sensors & Process Contro

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.