LAISHA
Open Laisha

ICAR AIEEA-PG Instrumentation, Sensors & Process Control: practice questions

ICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) · India · National Testing Agency for ICAR

Original practice questions written to the published syllabus · not past papers
10worked here, free
40written to this exam in this subject
11syllabus units

About ICAR AIEEA-PG

ICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Instrumentation, Sensors & Process Control in ICAR AIEEA-PG

Basic instruments and measurement: errors, sensitivity, transducer classification, temperature and pressure measurement, ADC resolution and simple amplifier circuits.

Measuring temperature, pressure, flow, force and moisture, logging the data, and controlling processes automatically.

Our 40 ICAR AIEEA-PG questions in this subject: 36 easy, 4 medium, 0 hard, across 11 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · easy

A grain-store data logger reads 0.8 °C above a reference thermometer at every temperature tested. What kind of error is this, and how is it dealt with?

  1. A random error, removed by averaging a larger number of readings at each point
  2. A gross error, removed by retraining the operator who read and noted the display
  3. A hysteresis error, removed by always approaching the reading from below
  4. A systematic error, removed by applying a calibration correction of −0.8 °C
Answer and working

D. A systematic error, removed by applying a calibration correction of −0.8 °C

A constant offset that repeats under the same conditions is systematic. Averaging does not shrink it, because every reading carries the same bias; a calibration correction (the negative of the error) removes it. Hysteresis would show a difference between rising and falling inputs, not a constant offset.

Question 2 · easy

A grain-probe temperature sensor has a time constant of 8 s. About how long after a step change does it show 95% of the change?

  1. 8 s
  2. 24 s
  3. 16 s
  4. 40 s
Answer and working

B. 24 s

A first-order response reaches 1 − e^(−3) = 95.0% at three time constants: 3 × 8 = 24 s. 8 s gives only 63.2%, 16 s (2τ) gives 86.5%, and 40 s (5τ) gives 99.3%.

Question 3 · medium

A Pt100 sensor (α = 0.00385 /°C, linear model) in a pasteuriser hot-water line reads 119.4 Ω. What is the temperature?

  1. 310.1 °C
  2. 19.4 °C
  3. 50.4 °C
  4. 7.5 °C
Answer and working

C. 50.4 °C

R = R0(1 + αT), so T = (R/R0 − 1)/α = (1.194 − 1)/0.00385 = 50.4 °C. 310.1 °C forgets to subtract 1; 19.4 °C takes the ohms change as degrees; 7.5 °C multiplies the 19.4 Ω change by α (with a factor-of-100 slip) instead of dividing.

Question 4 · easy

For a sharp-crested V-notch weir, discharge varies with upstream head H approximately as which power of H?

  1. H^1.5
  2. H^0.5
  3. H^2.0
  4. H^2.5
Answer and working

D. H^2.5

A triangular (V-notch) weir gives Q ∝ H^(5/2). H^1.5 is the rectangular weir; H^0.5 is the obstruction meter relation between flow and differential head.

Question 5 · easy

A 120 Ω foil strain gauge with gauge factor 2.0 is bonded to a plough beam that is strained to 500 µε. What is the change in its resistance?

  1. 0.12 Ω
  2. 1.20 Ω
  3. 0.06 Ω
  4. 120.0 Ω
Answer and working

A. 0.12 Ω

ΔR = R·GF·ε = 120 × 2.0 × 500×10⁻⁶ = 0.12 Ω. 1.20 Ω uses 5000 µε; 0.06 Ω forgets the gauge factor. Changes this small are why a Wheatstone bridge is needed.

Question 6 · easy

Strain gauges for measuring torque on a tractor PTO shaft are bonded at what angle to the shaft axis?

  1. 0°, along the shaft axis to sense the torque directly
  2. ±45°, along the principal strain directions of torsion
  3. 90°, around the circumference in the hoop direction
  4. ±30°, to balance torsion against the bending strain
Answer and working

B. ±45°, along the principal strain directions of torsion

Pure torsion produces equal tensile and compressive principal strains at ±45° to the axis. Gauges along the axis or circumference see no strain from pure torsion.

Question 7 · easy

Wheat has a moisture content of 15% wet basis. What is the moisture content on a dry basis?

  1. 13.0%
  2. 15.0%
  3. 12.8%
  4. 17.6%
Answer and working

D. 17.6%

Mdb = Mwb/(1 − Mwb) = 0.15/0.85 = 0.176 = 17.6%. 13.0% wrongly applies the reverse conversion (0.15/1.15); dry basis is always higher than wet basis for a moist product. 15.0% leaves the figure unconverted; 12.8% multiplies by (1 − Mwb) instead of dividing.

Question 8 · easy

What is the size of one least significant bit (LSB) for a 12-bit ADC with a 0–5 V input range?

  1. 4.88 mV
  2. 417 mV
  3. 1.22 mV
  4. 2.44 mV
Answer and working

C. 1.22 mV

LSB = FS/2ⁿ = 5/4096 = 1.22 mV. 4.88 mV is the 10-bit value; 417 mV divides by the number of bits instead of 2ⁿ; 2.44 mV assumes a 10 V range.

Question 9 · medium

A logger must resolve 0.1 °C over a 0–100 °C span. What is the minimum ADC resolution, assuming the full ADC range is used?

  1. 8 bits
  2. 10 bits
  3. 12 bits
  4. 7 bits
Answer and working

B. 10 bits

Steps needed = 100/0.1 = 1000; 2⁹ = 512 is too few and 2¹⁰ = 1024 is enough, so 10 bits. 8 bits gives only 256 steps (about 0.4 °C). In practice extra bits are chosen because noise and non-linearity reduce effective resolution. 7 bits gives 128 steps, enough only for about 0.8 °C; 12 bits works but is not the minimum.

Question 10 · easy

Low-power wide-area network (LPWAN) radios are chosen for many farm sensors. What do they trade away to gain multi-kilometre range on battery power?

  1. Range: they cover only a few metres around the node
  2. Security: they cannot carry any encrypted data at all
  3. Accuracy: they lower the precision of the sensor reading
  4. Data rate: they send only small packets, infrequently
Answer and working

D. Data rate: they send only small packets, infrequently

LPWAN achieves long range at low power by using very low data rates and small payloads, often with duty-cycle limits. That suits a soil-moisture reading every 15 minutes, not video. Encryption is supported, and the radio does not change sensor accuracy.

A study plan for Instrumentation, Sensors & Process Control in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (43% of the 40 questions): The generalised measurement system (5, 13%); IoT sensor networks (4, 10%); Moisture measurement (4, 10%); Pressure, flow and level measurement (4, 10%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Signal conditioning (4, 10%); Static and dynamic characteristics of instruments (4, 10%); Temperature transducers (4, 10%); Control modes: on-off, P, PI and PID (3, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Data acquisition and data loggers (3, 8%); Programmable logic controllers (3, 8%); Force, torque and strain: strain gauges and load cells (2, 5%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Bank the easy marks: IoT sensor networks (4 easy of 4); Moisture measurement (4 easy of 4).

    Do these early in revision so they are fast on the day.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Instrumentation, Sensors & Process Control

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.