ICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) · India · National Testing Agency for ICAR
Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Unit VII hydrology as single-answer MCQs: definitions (φ-index, IUH, S-curve, double-mass curve), gauge types, pan coefficients, formula recognition and short calculations with the +4/−1 marking.
Rain to runoff: measuring precipitation, subtracting losses, estimating runoff and routing floods.
Our 94 ICAR AIEEA-PG questions in this subject: 36 easy, 43 medium, 15 hard, across 13 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
A 200 km² catchment has mean annual rainfall 900 mm and a mean annual flow of 1.9 m³/s at its outlet. Taking long-term storage change and groundwater exchange as zero, estimate mean annual evapotranspiration.
D. About 600 mm
Runoff depth = 1.9 × 365 × 86,400 / (200 × 10⁶) = 0.2996 m = 300 mm. ET = P − R = 900 − 300 ≈ 600 mm. 300 mm is the runoff itself, not ET; 899 mm comes from converting only one day of flow; 1,200 mm adds runoff to rainfall.
Which rain gauge produces a series of electrical pulses, each representing a fixed small depth of rain, and is therefore well suited to telemetry?
C. Tipping-bucket gauge
Each tip of the bucket closes a contact, so the count per unit time gives intensity. The natural-siphon gauge draws a mass curve on a chart, and non-recording and storage gauges give only totals.
Isohyets of 20, 30, 40 and 50 mm are drawn over a 200 km² catchment. Areas between successive isohyets are 60 km² (20–30), 90 km² (30–40) and 50 km² (40–50). What is the mean rainfall by the isohyetal method?
A. 34.5 mm
Each band takes the mean of its bounding isohyets: (25×60 + 35×90 + 45×50)/200 = 34.5 mm. Using the lower isohyet of each band gives 29.5 mm and the upper gives 39.5 mm; 35.0 mm is an unweighted average of the band means.
Heavy rainfall on the windward slopes of a mountain range with a dry rain-shadow on the leeward side is characteristic of:
B. orographic precipitation
Air forced up a barrier cools and precipitates on the windward side. Convective rain comes from local surface heating, not from a barrier.
The largest single source of error in rainfall measured by a standard gauge is usually:
D. wind, which deflects drops over the orifice and causes under-catch
Wind turbulence around the gauge causes under-catch, more so for snow and fine drops. Evaporation and splash errors exist but are smaller with standard siting.
Which chemical is used as a monolayer to reduce evaporation from small reservoirs?
C. Cetyl alcohol (hexadecanol)
Long-chain fatty alcohols such as cetyl alcohol form a one-molecule film that reduces evaporation in calm weather. The others are salts or minerals with no such effect.
Hydrologic soil group A in the SCS curve number method refers to soils with:
D. high infiltration rates and low runoff potential, such as deep sands
Group A has the lowest runoff potential. Clays, high water tables and shallow soils over rock are group D.
A curve number of 100 indicates:
B. an impervious or water surface where all rainfall becomes runoff
CN = 100 gives S = 0, so Q = P. Maximum retention corresponds to CN approaching 0.
A 6-hour unit hydrograph can be obtained from a 3-hour unit hydrograph by:
B. adding two 3-hour unit hydrographs lagged by 3 hours and dividing the ordinates by 2
The lagged sum represents 2 cm in 6 hours, so dividing by 2 returns it to 1 cm. Simply doubling ordinates gives 2 cm in 3 hours, a different storm.
A 6-hour unit hydrograph can be obtained from a 3-hour unit hydrograph by:
B. adding two 3-hour unit hydrographs lagged by 3 hours and dividing the ordinates by 2
The lagged sum represents 2 cm in 6 hours, so dividing by 2 returns it to 1 cm. Simply doubling ordinates gives 2 cm in 3 hours, a different storm.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.