Tamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) · India · Tamil Nadu Public Service Commission
Original practice questions written to the published syllabus · not past papersTamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) is a government recruitment exam run by Tamil Nadu Public Service Commission, for candidates in India. Degree-standard subject paper (for posts such as Assistant Engineer (Agri)).
Source: tnpsc.gov.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Rain to runoff: measuring precipitation, subtracting losses, estimating runoff and routing floods.
Our 37 Tamil Nadu PSC questions in this subject: 19 easy, 14 medium, 4 hard, across 12 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to Tamil Nadu PSC and are not shown on any other exam's page.
A missing rainfall value may be estimated by the simple arithmetic average of index stations when:
C. every index station's normal annual rainfall is within 10% of the missing station's
The condition is on normal annual precipitation, not distance or number. If any normal differs by more than 10%, the normal ratio method is used.
A double-mass curve shows a slope of 0.84 for the older part of a station's record and 1.05 for the recent part. The record is to be adjusted to current conditions. An old annual value of 72 cm becomes:
A. 90.0 cm
Pcx = Px × Mc/Ma = 72 × 1.05/0.84 = 90.0 cm, where Mc is the slope of the period adjusted to. 57.6 cm inverts the ratio; 75.6 cm multiplies by only one slope.
A local IDF relation is i = 1500 T^0.18 / (D + 15)^0.75, with i in mm/h, T in years and D in minutes. What is the design intensity for T = 25 years and D = 45 minutes?
B. 124.2 mm/h
i = 1500 × 25^0.18 / 60^0.75 = 1500 × 1.785 / 21.56 = 124.2 mm/h. Dropping the constant 15 gives 154.1; dropping T^0.18 gives 69.6; entering D in hours gives 338.7 mm/h.
A 25 ha catchment has a runoff coefficient of 0.4 and a design intensity of 60 mm/h. The peak runoff by the rational method is:
B. 1.667 m³/s
With A in hectares, Q = CiA/360 = 0.4 × 60 × 25/360 = 1.667 m³/s. Using the km² constant 3.6 with hectares gives 166.7 m³/s (100 times too large), dividing by 36,000 gives 0.0167 m³/s, and omitting the constant gives CiA = 600.
In the rational method, the duration of the design rainfall is taken equal to:
B. the time of concentration of the catchment
Peak flow occurs when the whole catchment contributes, which takes tc; the intensity for that duration is read from the IDF curve.
A D-hour unit hydrograph is the direct runoff hydrograph resulting from:
B. one unit of effective rainfall spread uniformly over the catchment at a steady rate for D hours
The unit refers to effective (excess) rainfall, not total rainfall, and the duration D must be stated.
Current-meter readings at 0.2 and 0.8 of the depth in a vertical are 1.10 m/s and 0.70 m/s. The mean velocity in the vertical is:
A. 0.90 m/s
Mean = (1.10 + 0.70)/2 = 0.90 m/s. 1.80 is the sum without averaging.
In a flood, floats give an average surface velocity of 1.6 m/s over a cross-section of 12 m². Taking the mean velocity as 0.85 times the surface velocity, the discharge is about:
D. 16.3 m³/s
Q = 0.85 × 1.6 × 12 = 16.3 m³/s. Using surface velocity directly gives 19.2 m³/s, an overestimate because mean velocity is less than surface velocity; dividing by 0.85 gives 22.6 m³/s; and 0.85 × 1.6 = 1.36 is a velocity, not a discharge.
A district with a normal seasonal rainfall of 800 mm receives 380 mm. Under the classic IMD classification, this is:
D. severe drought (deficiency 52.5%)
Deficiency = (800 − 380)/800 = 52.5%, above 50%, so severe. Reading the proportion received (47.5%) as the deficiency is the tempting slip.
For a district and week, current NDVI is 0.42, and the historical minimum and maximum NDVI for that week are 0.30 and 0.70. The Vegetation Condition Index is:
D. 30%
VCI = (NDVI − NDVImin)/(NDVImax − NDVImin) × 100 = (0.42 − 0.30)/(0.40) × 100 = 30%. 60% divides by the maximum only; 70% measures distance from the maximum instead. 42% simply reads the current NDVI as a percentage.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.