LAISHA
Open Laisha

Tamil Nadu PSC Sprinkler & Micro-Irrigation Systems: practice questions

Tamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) · India · Tamil Nadu Public Service Commission

Original practice questions written to the published syllabus · not past papers
10worked here, free
45written to this exam in this subject
14syllabus units

About Tamil Nadu PSC

Tamil Nadu PSC — Agricultural Engineering (Code 164, degree standard) is a government recruitment exam run by Tamil Nadu Public Service Commission, for candidates in India. Degree-standard subject paper (for posts such as Assistant Engineer (Agri)).

Source: tnpsc.gov.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Sprinkler & Micro-Irrigation Systems in Tamil Nadu PSC

Designing and evaluating sprinkler and drip systems, from emitter hydraulics to pump selection.

Our 45 Tamil Nadu PSC questions in this subject: 31 easy, 12 medium, 2 hard, across 14 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to Tamil Nadu PSC and are not shown on any other exam's page.

Question 1 · medium

A sprinkler catch pattern shows almost no water near the sprinkler and a heavy ring near the edge of the wetted circle, with large drops. What is the most likely cause?

  1. Operating pressure too high for the nozzle
  2. Riser too tall
  3. Nozzle worn oversize at correct pressure
  4. Operating pressure too low for the nozzle
Answer and working

D. Operating pressure too low for the nozzle

Low pressure does not break up the jet, so large drops travel to the outer part of the circle, giving the 'doughnut' pattern. Excess pressure does the opposite: fine drops, mist, drift and extra water near the sprinkler.

Question 2 · easy

A net depth of 60 mm is to be applied by a portable lateral with application efficiency 75 % at an application rate of 8 mm/h. What is the set time?

  1. 10.0 h
  2. 7.5 h
  3. 5.62 h
  4. 13.3 h
Answer and working

A. 10.0 h

Gross depth = 60 / 0.75 = 80 mm; set time = 80 / 8 = 10.0 h. Dividing the net depth by the rate gives 7.5 h and multiplying by efficiency gives 5.62 h, both of which under-irrigate; 13.3 h divides by efficiency twice.

Question 3 · medium

How is sprinkler spacing normally adjusted as the design wind speed at a site increases?

  1. Spacing is increased to exploit the longer downwind throw of each sprinkler jet
  2. Spacing is unchanged but pressure is lowered
  3. Only the riser height is changed
  4. Spacing is reduced as a fraction of wetted diameter, especially across the wind
Answer and working

D. Spacing is reduced as a fraction of wetted diameter, especially across the wind

Wind distorts and shortens the wetted pattern upwind and across the wind, so overlap must increase: spacing is set at a smaller fraction of the wetted diameter, often closest across the wind. Lowering pressure produces larger drops but does not restore overlap.

Question 4 · easy

Christiansen's uniformity coefficient is based on which statistic of catch-can depths?

  1. The mean absolute deviation from the mean
  2. The standard deviation
  3. The range between highest and lowest catch
  4. The mean of the lowest quarter
Answer and working

A. The mean absolute deviation from the mean

CU = 100 [1 − Σ|xi − x̄| / (n x̄)] uses absolute deviations. The standard deviation is used by the Wilcox–Swailes coefficient and by statistical uniformity; the lowest quarter is used by distribution uniformity.

Question 5 · medium

A PVC mainline of 125 mm internal diameter carries 20 L/s. What is the flow velocity, and is it within a common 1.5 m/s working limit for plastic mains?

  1. 0.41 m/s; well within the limit
  2. 1.63 m/s; slightly above the limit
  3. 6.52 m/s; far above the limit
  4. 0.163 m/s; well within the limit
Answer and working

B. 1.63 m/s; slightly above the limit

V = Q/A = 0.020 / (π/4 × 0.125²) = 0.020 / 0.01227 = 1.63 m/s, just over 1.5 m/s, so the next larger size should be checked on annual cost and surge. Using πD² instead of πD²/4 for area gives 0.41 m/s.

Question 6 · easy

Drip laterals are most commonly made of which material?

  1. Galvanised steel
  2. Polyethylene
  3. Asbestos cement
  4. Aluminium
Answer and working

B. Polyethylene

Laterals are flexible polyethylene tubing (commonly LLDPE/LDPE blends) because it is cheap, flexible, resistant to fertilisers and allows emitters to be inserted or moulded in. Aluminium is used for portable sprinkler laterals; PVC is common for buried mains.

Question 7 · easy

A crop needs 60 kg N/ha in 12 equal fertigations on 2.5 ha, supplied as urea (46 % N). How much urea is needed per fertigation?

  1. 12.5 kg
  2. 326 kg
  3. 10.9 kg
  4. 27.2 kg
Answer and working

D. 27.2 kg

N per fertigation = 60/12 × 2.5 = 12.5 kg; urea = 12.5/0.46 = 27.2 kg. 12.5 kg is N, not urea; 326 kg is the season's total; 10.9 kg is per hectare only.

Question 8 · easy

What does the economic pipe size minimise?

  1. Pipe cost alone
  2. Friction loss alone
  3. Water velocity alone
  4. The sum of annualised pipe cost and annual pumping energy cost
Answer and working

D. The sum of annualised pipe cost and annual pumping energy cost

Larger pipes cost more but save energy by reducing friction. The economic size is the one with the least total annual cost; minimising pipe cost alone leads to high energy bills, and minimising friction alone leads to oversized pipes.

Question 9 · easy

A micro-irrigation system costs 150 000 and yields a net annual benefit of 50 000. What is the simple payback period?

  1. 0.33 years
  2. 2 years
  3. 3 years
  4. 4 years
Answer and working

C. 3 years

Simple payback = capital / annual net benefit = 150 000 / 50 000 = 3 years. 0.33 is the inverse ratio. Simple payback ignores the time value of money, which NPV and IRR include. 2 years deducts one year's benefit from the capital first ((150 000 − 50 000)/50 000); 4 years adds it instead ((150 000 + 50 000)/50 000).

Question 10 · medium

A farmer asks the government engineer what share of drip system cost a national subsidy scheme will pay. What is the correct professional response?

  1. The subsidy is always 100 % for all farmers
  2. Subsidies never apply to drip
  3. Check the current guidelines: rates, ceilings and conditions change and vary by farmer category and region
  4. The subsidy equals the cost of the emitters and laterals only, in every state and every country that offers one
Answer and working

C. Check the current guidelines: rates, ceilings and conditions change and vary by farmer category and region

Subsidy schemes (often with higher rates for small and marginal farmers) set rates, area ceilings and component-certification conditions that change over time and between states or countries; the engineer should quote the current guideline.

A study plan for Sprinkler & Micro-Irrigation Systems in Tamil Nadu PSC

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (49% of the 45 questions): Drip system components (5, 11%); Sprinkler types and components (5, 11%); Christiansen's uniformity coefficient (4, 9%); Economics of pressurised irrigation (4, 9%); Fertigation (4, 9%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Sprinkler spacing and application rate (4, 9%); Allowable pressure variation and the friction factor F (3, 7%); Filtration (3, 7%); Sprinkler lateral and main design (3, 7%); Automation (2, 4%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Drip lateral and sub-main design (2, 4%); Emission uniformity (2, 4%); Emitter hydraulics: exponent and coefficient of variation (2, 4%); System layout and pump selection (2, 4%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Emission uniformity (1 hard of 2), Allowable pressure variation and the friction factor F (1 hard of 3).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Automation (2 easy of 2); Drip lateral and sub-main design (2 easy of 2).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — Tamil Nadu PSC Sprinkler & Micro-Irrigation Systems

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.