Irrigation Association Certified Irrigation Designer — Agriculture (CID) · USA · Irrigation Association
Original practice questions written to the published syllabus · not past papersIrrigation Association Certified Irrigation Designer — Agriculture (CID) is a professional certification run by Irrigation Association, for candidates in USA. General Ag exam (150 MCQs, 4 h) plus a specialty exam — Drip/Micro (75 questions, 4 h) or Sprinkler (50 questions, 4 h) — all within 3 years.
Source: irrigation.org.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Designing and evaluating sprinkler and drip systems, from emitter hydraulics to pump selection.
Our 37 Irrigation Association Certified Irrigation Designer questions in this subject: 3 easy, 24 medium, 10 hard, across 14 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to Irrigation Association Certified Irrigation Designer and are not shown on any other exam's page.
On a centre pivot with sprinklers at equal spacing along the lateral, how must the discharge of each sprinkler vary with its distance r from the pivot to apply a uniform depth?
A. In proportion to r
Each sprinkler at radius r with spacing s serves an annulus of area about 2πr·s per revolution, so for equal depth its discharge must be proportional to r. Discharge proportional to r² would be the case only if the ring area grew with r², which it does not for a fixed spacing.
In a subsurface drip system, why is a vacuum-relief valve installed at the high points of each zone?
D. To stop suction pulling soil particles into emitters when the zone drains after shut-off
When a buried zone drains, a vacuum can form and draw soil and water back through the emitters, causing clogging. Vacuum relief admits air instead. Air release during filling is a separate function, often in the same combination valve.
When sampling emitters for a field emission uniformity test, where are laterals usually chosen along the sub-main?
D. At the inlet, about one-third and two-thirds along, and the far end
The standard procedure samples laterals at the start, one-third, two-thirds and end of the sub-main, and emitters at similar positions along each lateral, so both hydraulic variation and position effects are captured.
To meet a flushing velocity of 0.3 m/s at the end of a lateral with internal diameter 13.6 mm, what flow must leave the flush point?
A. About 157 L/h
Q = V × A = 0.3 × π/4 × 0.0136² = 4.358e-05 m³/s = 0.0436 L/s = 157 L/h. Using πD² (no /4) gives about 628 L/h; dividing by 3.6 instead of multiplying by 3600 gives about 44. About 0.16 L/h multiplies 0.0436 L/s by 3.6, which gives m³/h, and labels it L/h.
A well water analysis gives pH 8.2, iron 2.0 mg/L and suspended solids 30 mg/L. Using the Bucks–Nakayama clogging-hazard guide, how is the overall clogging hazard classed?
C. Severe, because of iron and pH
In the Bucks–Nakayama guide, pH above 8 and iron above 1.5 mg/L are each in the severe class, even though suspended solids below 50 mg/L are minor. Iron in well water oxidises on contact with air to form precipitates and supports iron bacteria.
Why are media filters installed as two or more tanks in parallel?
A. So one tank can be backflushed with water filtered by the others while the system runs
Backflushing reverses flow through one tank using clean water from the others; this keeps unfiltered water out of the system and allows continuous operation.
20 kg of N is injected evenly over 2 hours into a system flow of 40 m³/h. What is the N concentration in the irrigation water?
A. 250 mg/L
N rate = 20/2 = 10 kg/h = 10 000 g/h; concentration = 10 000 g/h ÷ 40 m³/h = 250 g/m³ = 250 mg/L (ppm). Ignoring the 2-hour duration gives 500; dividing by 0.46 gives the urea, not N, concentration. 0.25 mg/L leaves the result in kg/m³ (10/40) and labels it mg/L.
Why should filter losses be taken at their 'dirty' (backflush trigger) value when computing the TDH for pump selection?
D. Because the pump must still deliver the required pressure just before the filter is cleaned
Filter loss rises as it loads, up to the backflush set point. If the pump is selected with clean-filter loss, the critical block will be under-pressured for much of the time. Clean filters still have some loss, and the loss does depend on flow.
An automated drip controller raises a 'high flow' alarm for one zone. What is the most likely fault?
B. A burst or disconnected lateral or pipe in that zone
Flow above the zone's expected value points to a leak or break. A clogged filter, closed valve or clogged emitters reduce flow and would trigger a low-flow alarm.
In an evapotranspiration-based irrigation controller, what does the controller use to set the irrigation amount?
A. Reference ET from weather data multiplied by a crop coefficient, less effective rainfall
ET-based controllers compute crop water use from reference ET (measured or received from a weather station) and a crop coefficient, adjust for rainfall, and convert it to run time or volume for each zone.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.