LAISHA
Open Laisha

Irrigation Association Certified Irrigation Designer Sprinkler & Micro-Irrigation Systems: practice questions

Irrigation Association Certified Irrigation Designer — Agriculture (CID) · USA · Irrigation Association

Original practice questions written to the published syllabus · not past papers
10worked here, free
37written to this exam in this subject
14syllabus units

About Irrigation Association Certified Irrigation Designer

Irrigation Association Certified Irrigation Designer — Agriculture (CID) is a professional certification run by Irrigation Association, for candidates in USA. General Ag exam (150 MCQs, 4 h) plus a specialty exam — Drip/Micro (75 questions, 4 h) or Sprinkler (50 questions, 4 h) — all within 3 years.

Source: irrigation.org.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Sprinkler & Micro-Irrigation Systems in Irrigation Association Certified Irrigation Designer

Designing and evaluating sprinkler and drip systems, from emitter hydraulics to pump selection.

Our 37 Irrigation Association Certified Irrigation Designer questions in this subject: 3 easy, 24 medium, 10 hard, across 14 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to Irrigation Association Certified Irrigation Designer and are not shown on any other exam's page.

Question 1 · medium

On a centre pivot with sprinklers at equal spacing along the lateral, how must the discharge of each sprinkler vary with its distance r from the pivot to apply a uniform depth?

  1. In proportion to r
  2. Constant along the lateral
  3. In proportion to r²
  4. In inverse proportion to r
Answer and working

A. In proportion to r

Each sprinkler at radius r with spacing s serves an annulus of area about 2πr·s per revolution, so for equal depth its discharge must be proportional to r. Discharge proportional to r² would be the case only if the ring area grew with r², which it does not for a fixed spacing.

Question 2 · hard

In a subsurface drip system, why is a vacuum-relief valve installed at the high points of each zone?

  1. To release air during filling only
  2. To regulate pressure during operation
  3. To vent chlorine gas that collects inside the laterals after acid or chlorine treatment of the zone
  4. To stop suction pulling soil particles into emitters when the zone drains after shut-off
Answer and working

D. To stop suction pulling soil particles into emitters when the zone drains after shut-off

When a buried zone drains, a vacuum can form and draw soil and water back through the emitters, causing clogging. Vacuum relief admits air instead. Air release during filling is a separate function, often in the same combination valve.

Question 3 · medium

When sampling emitters for a field emission uniformity test, where are laterals usually chosen along the sub-main?

  1. Only at the inlet, where pressure is highest
  2. Only at the far end, where pressure is lowest
  3. At random across several fields
  4. At the inlet, about one-third and two-thirds along, and the far end
Answer and working

D. At the inlet, about one-third and two-thirds along, and the far end

The standard procedure samples laterals at the start, one-third, two-thirds and end of the sub-main, and emitters at similar positions along each lateral, so both hydraulic variation and position effects are captured.

Question 4 · medium

To meet a flushing velocity of 0.3 m/s at the end of a lateral with internal diameter 13.6 mm, what flow must leave the flush point?

  1. About 157 L/h
  2. About 44 L/h
  3. About 628 L/h
  4. About 0.16 L/h
Answer and working

A. About 157 L/h

Q = V × A = 0.3 × π/4 × 0.0136² = 4.358e-05 m³/s = 0.0436 L/s = 157 L/h. Using πD² (no /4) gives about 628 L/h; dividing by 3.6 instead of multiplying by 3600 gives about 44. About 0.16 L/h multiplies 0.0436 L/s by 3.6, which gives m³/h, and labels it L/h.

Question 5 · medium

A well water analysis gives pH 8.2, iron 2.0 mg/L and suspended solids 30 mg/L. Using the Bucks–Nakayama clogging-hazard guide, how is the overall clogging hazard classed?

  1. Minor, because suspended solids are low
  2. Moderate, because pH is between 7 and 8
  3. Severe, because of iron and pH
  4. No hazard, as the water is from a well
Answer and working

C. Severe, because of iron and pH

In the Bucks–Nakayama guide, pH above 8 and iron above 1.5 mg/L are each in the severe class, even though suspended solids below 50 mg/L are minor. Iron in well water oxidises on contact with air to form precipitates and supports iron bacteria.

Question 6 · medium

Why are media filters installed as two or more tanks in parallel?

  1. So one tank can be backflushed with water filtered by the others while the system runs
  2. Because a single tank usually cannot hold enough sand media to filter the full system design flow
  3. To double the filtration fineness
  4. Because regulations forbid single tanks
Answer and working

A. So one tank can be backflushed with water filtered by the others while the system runs

Backflushing reverses flow through one tank using clean water from the others; this keeps unfiltered water out of the system and allows continuous operation.

Question 7 · medium

20 kg of N is injected evenly over 2 hours into a system flow of 40 m³/h. What is the N concentration in the irrigation water?

  1. 250 mg/L
  2. 500 mg/L
  3. 0.25 mg/L
  4. 543 mg/L
Answer and working

A. 250 mg/L

N rate = 20/2 = 10 kg/h = 10 000 g/h; concentration = 10 000 g/h ÷ 40 m³/h = 250 g/m³ = 250 mg/L (ppm). Ignoring the 2-hour duration gives 500; dividing by 0.46 gives the urea, not N, concentration. 0.25 mg/L leaves the result in kg/m³ (10/40) and labels it mg/L.

Question 8 · hard

Why should filter losses be taken at their 'dirty' (backflush trigger) value when computing the TDH for pump selection?

  1. Because clean filters have no loss
  2. Because dirty filters reduce the pump's NPSH required and so allow a higher suction lift
  3. Because filter loss is independent of flow, so the dirty value is the only one that can be measured
  4. Because the pump must still deliver the required pressure just before the filter is cleaned
Answer and working

D. Because the pump must still deliver the required pressure just before the filter is cleaned

Filter loss rises as it loads, up to the backflush set point. If the pump is selected with clean-filter loss, the critical block will be under-pressured for much of the time. Clean filters still have some loss, and the loss does depend on flow.

Question 9 · medium

An automated drip controller raises a 'high flow' alarm for one zone. What is the most likely fault?

  1. A clogged filter
  2. A burst or disconnected lateral or pipe in that zone
  3. A closed valve
  4. Emitter clogging
Answer and working

B. A burst or disconnected lateral or pipe in that zone

Flow above the zone's expected value points to a leak or break. A clogged filter, closed valve or clogged emitters reduce flow and would trigger a low-flow alarm.

Question 10 · medium

In an evapotranspiration-based irrigation controller, what does the controller use to set the irrigation amount?

  1. Reference ET from weather data multiplied by a crop coefficient, less effective rainfall
  2. Only the day of the week
  3. The pump's power consumption
  4. The pressure measured at the far end of the lateral, compared with the design operating pressure
Answer and working

A. Reference ET from weather data multiplied by a crop coefficient, less effective rainfall

ET-based controllers compute crop water use from reference ET (measured or received from a weather station) and a crop coefficient, adjust for rainfall, and convert it to run time or volume for each zone.

A study plan for Sprinkler & Micro-Irrigation Systems in Irrigation Association Certified Irrigation Designer

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (54% of the 37 questions): Fertigation (5, 14%); Filtration (5, 14%); System layout and pump selection (4, 11%); Automation (3, 8%); Emission uniformity (3, 8%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Emitter hydraulics: exponent and coefficient of variation (3, 8%); Christiansen's uniformity coefficient (2, 5%); Drip lateral and sub-main design (2, 5%); Drip system components (2, 5%); Economics of pressurised irrigation (2, 5%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Sprinkler lateral and main design (2, 5%); Sprinkler spacing and application rate (2, 5%); Allowable pressure variation and the friction factor F (1, 3%); Sprinkler types and components (1, 3%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Christiansen's uniformity coefficient (1 hard of 2), Drip system components (1 hard of 2), Economics of pressurised irrigation (1 hard of 2).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Emission uniformity (1 easy of 3); Emitter hydraulics: exponent and coefficient of variation (1 easy of 3).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — Irrigation Association Certified Irrigation Designer Sprinkler & Micro-Irrigation Systems

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.