Sprinkler & Micro-Irrigation Systems in ICAR AIEEA-PG

Designing and evaluating sprinkler and drip systems, from emitter hydraulics to pump selection.

Our 65 ICAR AIEEA-PG questions in this subject: 28 easy, 32 medium, 5 hard, across 14 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · hard

A sprinkler discharges 0.40 L/s at 250 kPa. Estimate its discharge if the pressure is raised to 350 kPa.

  1. 0.560 L/s
  2. 0.473 L/s
  3. 0.784 L/s
  4. 0.338 L/s
Answer and working

B. 0.473 L/s

Nozzle discharge varies with the square root of pressure: q2 = 0.40 × √(350/250) = 0.40 × 1.1832 = 0.473 L/s. Assuming discharge proportional to pressure gives 0.560 L/s, and to pressure squared 0.784 L/s; inverting the pressure ratio gives 0.338 L/s.

Question 2 · medium

A sprinkler lateral runs uphill with a 3 m rise from inlet to end. Design average head is 25 m, friction loss 4 m, riser 1 m. What inlet head is required?

  1. 27.5 m
  2. 32.0 m
  3. 29.5 m
  4. 30.5 m
Answer and working

D. 30.5 m

Hinlet = Ha + ¾ hf + ½ ΔZ + Hr = 25 + 3 + 1.5 + 1 = 30.5 m (plus sign for uphill). Subtracting ½ ΔZ (the downhill case) gives 27.5 m; adding the full rise gives 32.0 m. 29.5 m omits the riser height.

Question 3 · easy

In a drip head unit, where is a screen or disc filter placed relative to the fertiliser injection point?

  1. Upstream of the pump only
  2. After the injector
  3. At the end of each lateral
  4. Only at the water source intake
Answer and working

B. After the injector

The injected fertiliser can contain undissolved particles or form precipitates, so a screen or disc filter is placed after the injector to protect emitters. A primary filter (media or hydrocyclone) may still sit upstream.

Question 4 · medium

How does a pressure-compensating emitter keep its discharge nearly constant as inlet pressure rises?

  1. A spring-loaded ball closes a second outlet
  2. The emitter body stretches to enlarge the orifice
  3. A flexible diaphragm deforms and narrows the flow passage
  4. A float valve in the lateral limits pressure
Answer and working

C. A flexible diaphragm deforms and narrows the flow passage

In a PC emitter, higher pressure presses an elastomeric diaphragm against the outlet or channel, narrowing it so that discharge stays nearly constant within the compensating range, giving an exponent near zero.

Question 5 · hard

A 30 m drip lateral (internal diameter 13.6 mm, Hazen-Williams C = 150) carries emitters of 2 L/h at 0.5 m spacing. Using Christiansen's F with m = 1.852, what is the friction loss?

  1. 0.188 m
  2. 0.067 m
  3. 0.094 m
  4. 0.72 m
Answer and working

B. 0.067 m

N = 30/0.5 = 60; Q = 60 × 2 = 120 L/h = 3.333e-05 m³/s. hf(no outlets) = 10.67 × 30 × Q^1.852/(150^1.852 × 0.0136^4.87) = 0.188 m. F = 0.3506 + 1/120 + √0.852/(6 × 3600) = 0.359. hf = 0.188 × 0.359 = 0.067 m. Omitting F gives 0.188 m; using F = 0.5 gives 0.094 m; converting L/h to L/s wrongly (× 3.6 flow) gives 0.72 m (0.067 × 3.6^1.852).

Question 6 · medium

A sub-main runs across a uniform slope and feeds laterals running up and down the slope from the same connection. Why is the downhill lateral usually made longer than the uphill one?

  1. Because downhill laterals carry less water per emitter, so they can be longer for the same pipe diameter
  2. To reduce the number of flush valves
  3. So elevation gain downhill and loss uphill balance friction, giving both lateral ends similar pressure
  4. Because uphill laterals must be larger in diameter
Answer and working

C. So elevation gain downhill and loss uphill balance friction, giving both lateral ends similar pressure

Paired laterals are positioned so that the uphill lateral, which loses pressure to both friction and elevation, is short, and the downhill lateral, whose friction is partly offset by elevation gain, is longer, equalising end pressures and uniformity.

Question 7 · medium

What is the main practical characteristic of a venturi injector?

  1. It has no moving parts but needs a substantial pressure difference across it to create suction
  2. It gives constant ratio injection at any pressure
  3. It needs an electric motor
  4. It delivers the fertiliser as a steadily decaying concentration from a closed pressurised tank
Answer and working

A. It has no moving parts but needs a substantial pressure difference across it to create suction

A venturi draws solution at its throat by the pressure drop created; it is cheap and simple but consumes head, and its suction rate depends on the inlet and outlet pressures (read from the maker's chart). The decaying concentration describes the bypass tank, not the venturi.

Question 8 · easy

A pump delivers 20 L/s against 45 m total head at 70 % efficiency. What shaft power does it need?

  1. 8.83 kW
  2. 6.18 kW
  3. 126 kW
  4. 12.6 kW
Answer and working

D. 12.6 kW

P = ρ g Q H / η = 1000 × 9.81 × 0.020 × 45 / 0.70 = 12613 W = 12.6 kW. 8.83 kW is the hydraulic power; multiplying by η instead of dividing gives 6.18 kW. 126 kW is a factor-of-ten slip.

Question 9 · easy

What is the advantage of a volumetric irrigation controller over a time-based one?

  1. It closes each valve after a set volume, compensating for pressure change or filter loading
  2. It needs no flow meter, because it calculates the volume from the valve opening time and pressure
  3. It works without electricity or hydraulics
  4. It ignores leaks and bursts in the zone, so its programming is simpler than a timer's
Answer and working

A. It closes each valve after a set volume, compensating for pressure change or filter loading

A volumetric controller measures water actually delivered with a meter, so the dose is correct even if flow falls because of pressure changes or filter loading. A time-based controller delivers less water when flow falls.

Question 10 · medium

A pump draws 15 kW input power and runs 600 h per season. Electricity costs 7 currency units per kWh. What is the seasonal energy cost?

  1. 63 000
  2. 9 000
  3. 63
  4. 105
Answer and working

A. 63 000

Energy = 15 kW × 600 h = 9 000 kWh; cost = 9 000 × 7 = 63 000. 9 000 is the energy, not the cost; dividing by 1000 treats kW as W; 105 omits the hours.

A study plan for Sprinkler & Micro-Irrigation Systems in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (45% of the 65 questions): Sprinkler types and components (7, 11%); Christiansen's uniformity coefficient (6, 9%); Sprinkler spacing and application rate (6, 9%); Allowable pressure variation and the friction factor F (5, 8%); Drip system components (5, 8%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Economics of pressurised irrigation (5, 8%); Fertigation (5, 8%); Sprinkler lateral and main design (5, 8%); Drip lateral and sub-main design (4, 6%); Emitter hydraulics: exponent and coefficient of variation (4, 6%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Filtration (4, 6%); System layout and pump selection (4, 6%); Automation (3, 5%); Emission uniformity (2, 3%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Drip lateral and sub-main design (1 hard of 4), Allowable pressure variation and the friction factor F (1 hard of 5), Sprinkler lateral and main design (1 hard of 5).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Automation (2 easy of 3); Drip system components (3 easy of 5).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Sprinkler & Micro-Irrigation Systems

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.