Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG — Agricultural Engineering & Technology (Major Subject Group 10) is a postgraduate admission exam run by National Testing Agency for ICAR, for candidates in India. Computer-based, 120 minutes, 120 MCQs, +4 / −1, English only (2026 bulletin). One paper for the whole subject group.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Unit V 'renewable energy': definitions and principles — solar radiation instruments, flat-plate collector parts and efficiency, solar dryers, cookers, stills and water heaters, PV cell characteristics, wind turbine types and the Betz limit — with short calculations.
Solar thermal, solar PV, wind and micro-hydro for farms, from sun geometry to sizing a solar pump.
Our 74 ICAR AIEEA-PG questions in this subject: 31 easy, 43 medium, 0 hard, across 14 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.
One kilowatt-hour of energy is equal to:
B. 3.6 MJ
1 kWh = 1000 W × 3600 s = 3.6 × 10⁶ J = 3.6 MJ. 3.6 kJ is the energy of 1 W for an hour (1 Wh), a factor-of-1000 slip. 36 MJ is a factor-of-ten slip.
What is the air mass when the sun is at a zenith angle of 60°?
D. 2.0
Air mass m ≈ 1/cos θz = 1/cos 60° = 1/0.5 = 2.0. 0.5 is cos θz itself; 1.5 is the standard PV rating spectrum (θz ≈ 48°); 1.15 is 1/cos 30°, confusing zenith with altitude.
Anti-islanding protection in a grid-connected PV inverter:
B. Disconnects the inverter when the grid fails, so the system does not energise lines being repaired
An 'island' is a section of network kept live by local generators after the grid has gone down; it endangers line workers. Grid-tied inverters must shut down on loss of grid, which is why an ordinary on-grid system without battery backup gives no power in an outage.
In most farm solar pumping systems, energy for cloudy periods is stored mainly as:
C. Water in an elevated tank or reservoir
Storing water is far cheaper and longer-lived than storing electricity, so most solar pumps are battery-less and directly coupled through a controller, with a tank or the soil profile buffering supply.
The Betz limit, the maximum fraction of wind power that any open rotor can extract, is:
D. 16/27 ≈ 0.593
Momentum theory gives Cp = 4a(1 − a)², maximised at a = 1/3, where Cp = 16/27 ≈ 0.593. 2/3 is the velocity ratio at the rotor at that condition and 1/3 is the induction factor, not the power coefficient.
In a run-of-river micro-hydro scheme, the forebay is:
A. A tank at the penstock head that settles sediment and gives a steady water level at the penstock inlet
Water from the headrace enters the forebay, where sediment settles and a stable level prevents air being drawn into the penstock. The penstock is the pressure pipe, the tailrace returns water, and run-of-river schemes have no seasonal storage dam.
1000 m³ of water is pumped into a reservoir 50 m above the turbine. With a round-trip efficiency of 75%, how much electrical energy can be recovered?
C. 102.2 kWh
Stored energy = ρgVh = 1000 × 9.81 × 1000 × 50 = 490.5 MJ = 136.25 kWh. Recovered = 0.75 × 136.25 = 102.2 kWh. Ignoring efficiency gives 136.2; forgetting the water density (using volume as mass) gives 0.102 kWh. 181.7 kWh divides by the efficiency instead of multiplying.
Which of these concentrators is a line-focus system that uses rows of nearly flat mirror strips?
C. Linear Fresnel reflector
A linear Fresnel reflector approximates a trough with many flat or slightly curved strips focusing on a fixed linear receiver above them. Dishes and towers are point-focus; a CPC uses two parabolic segments, not flat strips.
The clearness index KT is defined as:
C. The ratio of global horizontal radiation to extraterrestrial horizontal radiation over the same period
KT = H/H0. It is used to correlate the diffuse fraction. n/N is the relative sunshine duration used in Ångström–Prescott, a different quantity.
In the perturb-and-observe MPPT method, if a small increase in operating voltage produces a decrease in array power, the controller should next:
D. Decrease the operating voltage
A power drop after a voltage increase means the operating point has passed the maximum and is on the right side of the peak, so the perturbation direction is reversed. The method then oscillates around the maximum power point.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.