GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)
Original practice questions written to the published syllabus · not past papersGATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.
Source: gate2027.iitm.ac.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Section 3 Sources of Power: one- and two-mark numerical questions on the PV fill factor, module efficiency and area, power in the wind (½ρAV³), the Betz limit and power coefficient, and tip speed ratio. Unit discipline (kW vs kWh, rpm vs rad/s, diameter vs radius) decides marks. Solar geometry and collector efficiency appear less often but are fair game.
Solar thermal, solar PV, wind and micro-hydro for farms, from sun geometry to sizing a solar pump.
Our 44 GATE questions in this subject: 7 easy, 29 medium, 8 hard, across 13 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE and are not shown on any other exam's page.
Estimate the day length at latitude 30° N when the declination is +23.45°.
B. 13.9 h
Sunset hour angle ωs = cos⁻¹(−tan 30° × tan 23.45°) = cos⁻¹(−0.2504) = 104.50°. Day length N = 2ωs/15 = 13.93 h. Using ωs/15 alone gives only half the day (7.0 h); 12 h is the equinox value; 10.1 h is the night length.
At solar noon, latitude 30° N, declination −20°, a south-facing collector is tilted at 40°. What is the beam tilt factor Rb?
B. 1.53
At noon θ = |φ − β − δ| = |30 − 40 + 20| = 10° and θz = |φ − δ| = |30 + 20| = 50°. Rb = cos 10° / cos 50° = 0.9848/0.6428 = 1.53. Inverting the ratio gives 0.65; treating δ as +20° gives 0.88. 1.00 treats the collector as horizontal.
A basin-type solar still has a daily efficiency of 35%. Daily insolation is 20 MJ/m² and the latent heat of vaporisation is 2.35 MJ/kg. What is the daily distillate output per square metre?
C. 2.98 kg/m²
Output = ηH/L = 0.35 × 20 / 2.35 = 2.98 kg/m² per day, in the usual 2–3 L/m² range for basin stills. Omitting efficiency gives 8.51, far above what any still achieves; 0.041 inverts H/L while keeping the efficiency factor (ηL/H = 0.35 × 2.35/20); 10.7 multiplies the correct 2.98 by 3.6, a spurious unit conversion.
An ideal silicon cell at 300 K has light-generated current 3 A and diode saturation current 1 × 10⁻⁹ A (ideality factor 1). What is its open-circuit voltage? (k = 1.381 × 10⁻²³ J/K, q = 1.602 × 10⁻¹⁹ C)
C. 0.564 V
kT/q = 1.381e-23 × 300 / 1.602e-19 = 0.02585 V. Voc = (kT/q) ln(IL/I0 + 1) = 0.02585 × ln(3 × 10⁹) = 0.02585 × 21.82 = 0.564 V. Using log₁₀ gives 0.245 V; working kT/q in mV and forgetting to convert gives 564.1 V; kT/q alone (0.0259 V) is only the thermal voltage.
A PV module has Voc = 21.6 V, Isc = 5.0 A, Vmp = 17.2 V and Imp = 4.65 A. What is its fill factor?
C. 0.741
FF = VmpImp/(VocIsc) = 79.98/108.0 = 0.741. Using only the voltage ratio (0.796) or current ratio (0.930) misses half the definition; the inverse, 1.350, is greater than one, which a fill factor can never be.
A 5 kWp PV plant produces 6,844 kWh in a year. What is its capacity utilisation factor?
A. 15.6%
CUF = E/(P × 8760) = 6844/(5 × 8760) = 0.1563 = 15.6%. Dividing by 365 instead of 8760 gives 375% (energy per day per kW, i.e. about 3.75 kWh/kWp/day, not a percentage); leaving the fraction unconverted (0.156%) mislabels it; 31.3% uses only 4380 daylight hours.
A turbine of 10 m rotor diameter has a power coefficient of 0.40 at 8 m/s. Taking ρ = 1.225 kg/m³, what shaft power does it produce?
A. 9.85 kW
Power in wind = ½ρAV³ = 24.63 kW (A = π × 5²). Shaft power = 0.40 × 24.63 = 9.85 kW. Omitting Cp gives the wind power; using 16/27 gives the Betz ceiling (14.60 kW); using D as radius gives 39.4 kW.
On a wind turbine power curve, the speed at which the turbine reaches its full nameplate output is the:
A. Rated wind speed
Cut-in is where generation starts, rated is where output reaches nameplate power and is then held constant by pitch or stall control, and cut-out is where the machine shuts down to protect itself in storms.
A micro-hydro scheme has a flow of 0.1 m³/s through a net head of 20 m with an overall efficiency of 60%. What electrical power does it produce?
D. 11.77 kW
P = ρgQHη = 1000 × 9.81 × 0.1 × 20 × 0.6 = 11772 W = 11.77 kW. Omitting efficiency gives 19.62 kW; forgetting ρg gives 1.2; treating 0.1 m³/s as 100 m³/s gives megawatts.
Two sites have the same mean wind speed. Site A has steady winds; Site B has the same mean but highly variable winds. Which site has the greater mean power density?
D. Site B, because the mean of V³ exceeds the cube of the mean when speeds vary
Power density is proportional to the mean of V³, which rises with variability even at fixed mean speed (the energy pattern factor). A turbine may not capture all of it, but the resource is larger at Site B.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.