LAISHA
Open Laisha

GATE Heat & Mass Transfer: practice questions

GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)

Original practice questions written to the published syllabus · not past papers
10worked here, free
90written to this exam in this subject
12syllabus units

About GATE

GATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.

Source: gate2027.iitm.ac.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Heat & Mass Transfer in GATE

Heat and Mass Transfer sits in Section 7 (Dairy and Food Engineering). Composite-wall conduction and heat-exchanger calculations (LMTD, and increasingly effectiveness–NTU) appear almost every year as one- or two-mark numerical-answer questions. Also expected: critical radius of insulation, lumped-capacitance cooling time, fin heat flow and efficiency, Stefan–Boltzmann exchange with view factors, Nusselt/Reynolds/Prandtl definitions and the Dittus–Boelter equation, Fick's law, and drying-rate and moisture-basis conversions that overlap with Section 6. Watch units (kJ/h against W, °C against K in radiation) and the choice of characteristic length.

Conduction, convection, radiation, heat exchangers and diffusion — the physics of drying, cooling, freezing and cold-store walls.

Our 90 GATE questions in this subject: 21 easy, 55 medium, 14 hard, across 12 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to GATE and are not shown on any other exam's page.

Question 1 · medium

A spherical storage vessel has an inner radius of 0.5 m and is covered with 0.1 m of insulation (k = 0.04 W/m·K). The insulation inner surface is at −5 °C and its outer surface at 25 °C. The steady heat gain through the insulation is

  1. 37.7 W
  2. 54.3 W
  3. 151 W
  4. 45.2 W
Answer and working

D. 45.2 W

Spherical shell resistance R = (r2 − r1)/(4πk r1 r2) = 0.1/(4π × 0.04 × 0.5 × 0.6) = 0.6631 K/W, so Q = 30/0.6631 = 45.2 W. Using the plane-wall formula with the inner area gives 37.7 W and with the outer area 54.3 W; dropping r1 r2 from the denominator gives 151 W.

Question 2 · medium

A cold-store wall of 150 m² consists of 230 mm brick (k = 0.7 W/m·K) and 100 mm insulation (k = 0.025 W/m·K). The outside air is at 40 °C with h = 20 W/m²·K and the inside air at 2 °C with h = 10 W/m²·K. The steady heat gain through the wall is closest to

  1. 1,320 W
  2. 1,270 W
  3. 11,900 W
  4. 8.5 W
Answer and working

B. 1,270 W

Resistance per m²: 1/20 + 0.23/0.7 + 0.10/0.025 + 1/10 = 0.05 + 0.3286 + 4.0 + 0.1 = 4.4786 m²·K/W. Flux q = 38/4.4786 = 8.485 W/m², and Q = 8.485 × 150 = 1,270 W. Ignoring the air films gives 1,320 W; leaving out the insulation gives 11,900 W; 8.5 W is the flux per square metre, not the total.

Question 3 · medium

Water (ν = 1.0 × 10⁻⁶ m²/s) flows at 0.5 m/s through a tube of 25 mm internal diameter. The Reynolds number and flow regime are

  1. 12,500; laminar
  2. 1,250; laminar
  3. 6,250; turbulent
  4. 12,500; turbulent
Answer and working

D. 12,500; turbulent

Re = VD/ν = 0.5 × 0.025/1.0 × 10⁻⁶ = 12,500. Pipe flow is laminar below about 2,300, so this is turbulent. Entering D as 2.5 mm gives 1,250; using the radius gives 6,250; calling Re = 12,500 laminar confuses the pipe limit with the flat-plate limit of about 5 × 10⁵.

Question 4 · medium

A small body obeying the lumped-capacitance model is plunged into a fluid. After a time equal to one time constant, its excess temperature (T − T∞) has fallen to about what fraction of the initial excess?

  1. 0.632
  2. 0.368
  3. 0.500
  4. 0.135
Answer and working

B. 0.368

θ/θ_i = exp(−t/τ) = e⁻¹ = 0.368 at t = τ. 0.632 is the fraction of the change already completed; 0.5 is the half-time (t = 0.693τ); 0.135 is reached after two time constants.

Question 5 · medium

Soil initially at a uniform 20 °C (α = 5 × 10⁻⁷ m²/s) has its surface suddenly brought to 0 °C and held there. Treat the soil as a semi-infinite solid, with (T − T_s)/(T_i − T_s) = erf[x/(2√(αt))]. Given erf(0.24) = 0.266, erf(0.48) = 0.503 and erf(0.96) = 0.825, the temperature at 0.1 m depth after 6 hours is closest to

  1. 16.5 °C
  2. 5.3 °C
  3. 9.94 °C
  4. 10.1 °C
Answer and working

D. 10.1 °C

√(αt) = √(5 × 10⁻⁷ × 21,600) = 0.1039 m, so x/(2√(αt)) = 0.1/0.2078 = 0.48; erf(0.48) = 0.503. T = 0 + 0.503 × 20 = 10.1 °C. Forgetting the 2 gives the argument 0.96 and 16.5 °C; using 4 gives 0.24 and 5.3 °C; using 1 − erf gives 9.94 °C, which would be the temperature for heating from 0 °C towards 20 °C.

Question 6 · medium

Oil (2.0 kg/s, c = 2.1 kJ/kg·K) is cooled by water (1.0 kg/s, c = 4.18 kJ/kg·K). The capacity ratio C_r and the fluid that has C_min are

  1. C_r = 0.995; oil has C_min
  2. C_r = 0.50; water has C_min
  3. C_r = 0.502; oil has C_min
  4. C_r = 0.995; water has C_min
Answer and working

D. C_r = 0.995; water has C_min

C_oil = 2.0 × 2.1 = 4.20 kW/K; C_water = 1.0 × 4.18 = 4.18 kW/K. Water has the smaller C, so C_r = 4.18/4.20 = 0.995. Comparing mass flows alone (0.50) or specific heats alone (0.502) is wrong: C is the product m·c.

Question 7 · easy

As the excess temperature of a heated surface in a pool of saturated water is increased, the boiling regimes follow the order

  1. natural convection → nucleate → transition → film boiling
  2. nucleate → natural convection → film → transition boiling
  3. film → transition → nucleate → natural convection boiling
  4. natural convection → film → nucleate → transition boiling
Answer and working

A. natural convection → nucleate → transition → film boiling

At small ΔT_e heat moves by natural convection; bubbles then form at nucleation sites (nucleate boiling) up to the critical heat flux; beyond it, unstable vapour patches (transition boiling) reduce the flux to a minimum at the Leidenfrost point; above that, a stable vapour film covers the surface (film boiling).

Question 8 · hard

Saturated steam condenses on a vertical plate 0.5 m high and 1 m wide whose surface is 10 °C below saturation. Liquid properties: ρ_l = 960 kg/m³, k_l = 0.68 W/m·K, μ_l = 2.8 × 10⁻⁴ Pa·s; h_fg = 2,257 kJ/kg; vapour density 0.6 kg/m³. Using h = 0.943[ρ_l(ρ_l − ρ_v)g h_fg k_l³/(μ_l L ΔT)]^(1/4), the condensate produced is closest to

  1. 61.9 kg/h
  2. 47.6 kg/h
  3. 6.19 kg/h
  4. 61,869 kg/h
Answer and working

A. 61.9 kg/h

h = 0.943 × [960 × 959.4 × 9.81 × 2.257 × 10⁶ × 0.68³/(2.8 × 10⁻⁴ × 0.5 × 10)]^0.25 = 7758 W/m²·K. Q = hAΔT = 7758 × 0.5 × 10 = 38788 W. Condensate = Q/h_fg = 38788/2.257 × 10⁶ = 0.01719 kg/s = 61.9 kg/h. Using the horizontal-tube constant gives 47.6; leaving ΔT out of Q = hAΔT gives 6.19; dividing by h_fg in kJ/kg gives a value 1,000 times too large. That value is 61,869 kg/h.

Question 9 · hard

Water at 25 °C evaporates from the bottom of a narrow tube into dry air flowing across the top, 0.15 m above the water surface. Total pressure is 101.325 kPa, the vapour pressure of water is 3.17 kPa, D = 2.6 × 10⁻⁵ m²/s and R = 8.314 kJ/kmol·K. Treating the air as stagnant, the evaporation flux is closest to

  1. 14.37 g/m²·h
  2. 0.0146 g/m²·h
  3. 14.60 g/m²·h
  4. 1591 g/m²·h
Answer and working

C. 14.60 g/m²·h

Diffusion of A through stagnant B: N_A = [DP/(RTL)] ln[(P − p_A2)/(P − p_A1)] = [2.6 × 10⁻⁵ × 101.325/(8.314 × 298 × 0.15)] × ln(101.325/98.155) = 2.25 × 10⁻⁷ kmol/m²·s. × 18 kg/kmol × 1,000 g/kg × 3,600 s/h = 14.60 g/m²·h. The simple Fick form without the bulk-flow factor gives 14.37 (about 1.6% lower here, because the vapour is dilute); 0.0146 is a kg-to-g slip; using ln(P/p_A1) mixes up the partial pressures of the stagnant gas and gives 1591.

Question 10 · easy

Grain with a moisture content of 20% (wet basis) has a dry-basis moisture content of

  1. 25%
  2. 16.7%
  3. 20%
  4. 80%
Answer and working

A. 25%

M_db = M_wb/(1 − M_wb) = 0.20/0.80 = 0.25 = 25%. 16.7% is the reverse conversion, M_wb = M_db/(1 + M_db), applied to 20%; 80% is the dry-matter fraction.

A study plan for Heat & Mass Transfer in GATE

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (39% of the 90 questions): Convection and dimensionless numbers (Nu, Re, Pr) (11, 12%); Composite walls and critical radius of insulation (8, 9%); Extended surfaces (fins) (8, 9%); Simultaneous heat and mass transfer in drying (8, 9%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Steady conduction through plane walls and cylinders (8, 9%); Transient conduction: lumped capacity and Heisler charts (8, 9%); Condensation and boiling (7, 8%); Heat exchangers: effectiveness-NTU method (7, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Heat exchangers: LMTD method (7, 8%); Radiation: Stefan-Boltzmann law and view factors (7, 8%); Diffusive mass transfer and Fick's law (6, 7%); Convective mass transfer (5, 6%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Heat exchangers: LMTD method (2 hard of 7), Steady conduction through plane walls and cylinders (2 hard of 8), Convection and dimensionless numbers (Nu, Re, Pr) (2 hard of 11).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Steady conduction through plane walls and cylinders (3 easy of 8); Condensation and boiling (2 easy of 7).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — GATE Heat & Mass Transfer

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.