LAISHA
Open Laisha

GATE Post-Harvest Engineering of Horticultural Crops: practice questions

GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)

Original practice questions written to the published syllabus · not past papers
10worked here, free
68written to this exam in this subject
11syllabus units

About GATE

GATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.

Source: gate2027.iitm.ac.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Post-Harvest Engineering of Horticultural Crops in GATE

Section 6 names processing of fruits, vegetables and spices and storage systems including CA/MA. Expect numerical items on moisture balances in drying, water removed, respiration heat and refrigeration load, half-cooling time and seven-eighths cooling, juice concentration and blending balances, and gas composition in CA/MA. Conceptual one-mark items test climacteric behaviour, ethylene, chilling injury, precooling method choice and dryer types.

Keeping fruits and vegetables alive and saleable after harvest: cooling, handling, packhouses, controlled atmospheres and processing.

Our 68 GATE questions in this subject: 9 easy, 27 medium, 32 hard, across 11 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to GATE and are not shown on any other exam's page.

Question 1 · medium

A leafy vegetable respires at 60 mg CO2/kg h at 20 degC and its Q10 is 2.5 over 0 to 20 degC. Its respiration rate at 0 degC is about

  1. 12.0 mg CO2/kg h
  2. 24.0 mg CO2/kg h
  3. 375 mg CO2/kg h
  4. 9.6 mg CO2/kg h
Answer and working

D. 9.6 mg CO2/kg h

Twenty degrees is two Q10 intervals: R(0) = 60 / 2.5^2 = 60 / 6.25 = 9.6. 12.0 comes from dividing by 2 x 2.5 = 5 instead of 2.5 squared; 24.0 applies only one interval.

Question 2 · hard

A forced-air cooler must remove 50 kW from produce. The air may warm by 3 K passing through the pallets. Taking air specific heat as 1.005 kJ/kg K and density 1.27 kg/m3, the required airflow is about

  1. 16.6 m3/s
  2. 21.1 m3/s
  3. 4.4 m3/s
  4. 13.1 m3/s
Answer and working

D. 13.1 m3/s

Mass flow = 50/(1.005 x 3) = 16.58 kg/s; volume = 16.58/1.27 = 13.1 m3/s. Quoting 16.6 m3/s treats kg/s as m3/s; 21.1 multiplies by density instead of dividing.

Question 3 · medium

Compared with room cooling, forced-air cooling of the same packed produce is faster mainly because

  1. the air supplied is much colder than the air used in room cooling
  2. it adds a film of water to the product surface, which then evaporates and cools it
  3. a pressure difference forces cold air through the carton vents past each item
  4. the packages are unstacked and spread out on the floor before cooling
Answer and working

C. a pressure difference forces cold air through the carton vents past each item

In room cooling air flows around stacks and heat must conduct out through packages; forced-air cooling pulls air through aligned carton vents so each item is swept by cold air. The air temperature is typically similar in both methods.

Question 4 · hard

Removing field heat from 1 t of produce (specific heat 3.8 kJ/kg K) cooled by 25 K, with a refrigeration system of coefficient of performance 3, requires about how much electrical energy (ignoring fans and losses)?

  1. 8.8 kWh
  2. 26.4 kWh
  3. 79 kWh
  4. 31.7 kWh
Answer and working

A. 8.8 kWh

Heat = 1 000 x 3.8 x 25 = 95 000 kJ = 26.4 kWh. Electricity = 26.4/3 = 8.8 kWh. 26.4 kWh is the heat itself; multiplying by COP gives 79 kWh; 31.7 treats MJ as kWh.

Question 5 · easy

A grading camera images a field of view 640 mm wide on a sensor 1 280 pixels wide. An 80 mm fruit spans about how many pixels?

  1. 40 pixels
  2. 16 pixels
  3. 80 pixels
  4. 160 pixels
Answer and working

D. 160 pixels

Resolution = 640/1 280 = 0.5 mm per pixel; 80 mm / 0.5 = 160 pixels. Multiplying by 0.5 gives 40. 16 pixels divides the sensor width by the fruit size (1 280/80).

Question 6 · medium

Why does a precooling facility need much more refrigeration capacity per tonne of produce than a holding cold store?

  1. Precooling removes a large temperature drop in hours; storage removes only respiration and leakage heat
  2. Holding stores are always better insulated, so far less heat leaks in through their walls and doors
  3. Precooling rooms are built without insulation, so most of their refrigeration is lost through the walls
  4. Holding stores use ice
Answer and working

A. Precooling removes a large temperature drop in hours; storage removes only respiration and leakage heat

Precooling must remove field heat, for example 20 to 30 K, in a few hours; once produce is cold, a store only balances vital heat and heat gains, which are much smaller.

Question 7 · hard

0.5 kg of produce with respiratory quotient 1 consumes 10 mL O2/kg h in a sealed film package of area 0.12 m2. The film's CO2 permeance is 24 000 mL/(m2 day atm) and outside CO2 is negligible. The steady-state CO2 inside is about

  1. 16.7%
  2. 0.17%
  3. 4.2%
  4. 8.3%
Answer and working

C. 4.2%

CO2 output = O2 uptake x RQ = 0.5 x 10 x 24 = 120 mL/day. 120 = 24 000 x 0.12 x p, so p = 120/2 880 = 0.0417 atm = 4.2%. Using the O2 permeance (6 000) instead gives 16.7%. 0.17% omits the x 24 h per day; 8.3% uses only half the film area.

Question 8 · medium

Case hardening in dried fruit is

  1. hardening due to sugar crystallisation on the fruit surface during long storage at low relative humidity
  2. a dry, impermeable surface layer formed by too-rapid surface drying, trapping internal moisture
  3. calcium deposition from hard water
  4. the result of blanching too long
Answer and working

B. a dry, impermeable surface layer formed by too-rapid surface drying, trapping internal moisture

Very hot, dry air early in drying can dry and shrink the surface faster than moisture can move from inside, forming a crust that slows further drying.

Question 9 · medium

Most spoilage bacteria cannot grow in a dried product whose water activity is below about

  1. 0.99
  2. 0.60
  3. 0.30
  4. 0.90
Answer and working

D. 0.90

Most bacteria need water activity above about 0.90; many yeasts and moulds grow down to about 0.80 to 0.88, and a few xerophilic moulds and osmophilic yeasts to about 0.60. 0.99 is nearly pure water, where almost everything grows, and 0.30 is far below the limit for any microbe.

Question 10 · medium

100 kg of green pepper berries at 70% moisture (wet basis) are dried to 10% moisture (wet basis). The mass of black pepper obtained is about

  1. 40.0 kg
  2. 30.0 kg
  3. 33.0 kg
  4. 33.3 kg
Answer and working

D. 33.3 kg

Dry matter = 100 x 0.30 = 30 kg; dried mass = 30/0.90 = 33.3 kg, about a third of fresh mass. 30 kg is dry matter with no water; 40 kg subtracts percentages. 33.0 kg adds 10% to the dry matter instead of dividing by 0.90.

A study plan for Post-Harvest Engineering of Horticultural Crops in GATE

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (60% of the 68 questions): Pre-cooling: hydro, forced-air and vacuum cooling (12, 18%); Dehydration of fruits and vegetables (11, 16%); Controlled and modified atmosphere storage (9, 13%); Respiration and ripening physiology (9, 13%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Juice extraction (8, 12%); Packhouse design (5, 7%); Grading, including machine vision (4, 6%); Processing of spices and plantation crops (3, 4%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Value addition (3, 4%); Minimal processing (2, 3%); Washing, sorting and waxing (2, 3%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Controlled and modified atmosphere storage (8 hard of 9), Value addition (2 hard of 3), Packhouse design (3 hard of 5).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Respiration and ripening physiology (3 easy of 9); Grading, including machine vision (1 easy of 4).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — GATE Post-Harvest Engineering of Horticultural Crops

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.