NCEES FE Other Disciplines · USA · NCEES
Original practice questions written to the published syllabus · not past papersNCEES FE Other Disciplines is a licensing and registration exam run by NCEES, for candidates in USA. Computer-based, 110 questions, 6-hour appointment (5 h 20 min exam).
Source: ncees.org.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Conduction, convection, radiation, heat exchangers and diffusion — the physics of drying, cooling, freezing and cold-store walls.
Our 42 NCEES FE Other Disciplines questions in this subject: 14 easy, 28 medium, 0 hard, across 11 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to NCEES FE Other Disciplines and are not shown on any other exam's page.
Air (ν = 1.5 × 10⁻⁵ m²/s) flows at 5 m/s along a long flat plate. Taking the critical Reynolds number for transition as 5 × 10⁵, the boundary layer becomes turbulent at a distance from the leading edge of about
D. 1.5 m
x_c = Re_c ν/V = 5 × 10⁵ × 1.5 × 10⁻⁵/5 = 1.5 m. Using the pipe value 2,300 gives 6.9 mm; using 5 × 10⁶ gives 15 m; 0.15 m is a factor-of-ten slip.
The Stefan–Boltzmann constant σ has the value
A. 5.67 × 10⁻⁸ W/m²·K⁴
E_b = σT⁴ with σ = 5.67 × 10⁻⁸ W/m²·K⁴. The unit must carry K⁴ because T is raised to the fourth power. 2,898 µm·K is Wien's displacement constant and 1.38 × 10⁻²³ J/K is Boltzmann's constant.
Two large parallel grey plates face each other: one at 800 K with emissivity 0.8, the other at 500 K with emissivity 0.6. The net radiant heat flux between them is closest to
B. 10,300 W/m²
q = σ(T1⁴ − T2⁴)/(1/ε1 + 1/ε2 − 1) = 5.67 × 10⁻⁸ × (4.10 × 10¹¹ − 6.25 × 10¹⁰)/(1.25 + 1.667 − 1) = 19,700/1.917 = 10,300 W/m². Treating both as black gives 19,700; multiplying the emissivities gives 9,450, which ignores reflections; using ε1 alone is the small-body-in-enclosure formula, which does not apply to parallel plates. Using ε1 alone gives 15,700 W/m².
Surface 1 has an area of 2 m² and surface 2 an area of 5 m². The view factor F12 is 0.6. The view factor F21 is
D. 0.24
Reciprocity: A1F12 = A2F21, so F21 = 2 × 0.6/5 = 0.24. Inverting the area ratio gives 1.50, which is impossible because a view factor cannot exceed 1; 1 − F12 misapplies the summation rule, which works across all surfaces seen from one surface, not between two surfaces. 1 − F12 gives 0.40.
The lumped-capacitance method for transient conduction is generally acceptable when the Biot number, based on L_c = V/A_s, is
C. less than 0.1
Bi = hL_c/k compares internal conduction resistance with external convection resistance. When Bi < 0.1 the internal temperature differences are small, so the body can be treated as one lump. A large Bi means large internal gradients.
In a counterflow heat exchanger the hot fluid is cooled from 120 °C to 70 °C and the cold fluid is heated from 20 °C to 60 °C. The log mean temperature difference is closest to
A. 54.8 °C
Counterflow: ΔT1 = 120 − 60 = 60 °C, ΔT2 = 70 − 20 = 50 °C. LMTD = (60 − 50)/ln(60/50) = 54.85 °C. The arithmetic mean, 55.0 °C, slightly overestimates it. Pairing the terminals as in parallel flow (100 and 10 °C) gives 39.1 °C; 43.4 °C does not follow from either terminal pairing (dividing ΔT1 alone by the logarithm would give 329 °C).
A 1-shell-pass, 2-tube-pass exchanger has U = 500 W/m²·K and A = 10 m². The counterflow LMTD for its terminal temperatures is 40 °C and the correction factor from the chart is F = 0.90. Its duty is
A. 180 kW
Q = UAF·ΔT_lm,cf = 500 × 10 × 0.90 × 40 = 180000 W = 180 kW. Omitting F gives 200 kW; dividing by F gives 222 kW. F ≤ 1 because multipass flow is less effective than pure counterflow. 162 kW applies F twice.
In the effectiveness–NTU method, the number of transfer units is defined as
D. UA/C_min
NTU = UA/C_min measures the thermal size of the exchanger. C_min/C_max is the capacity ratio C_r, and Q/Q_max is the effectiveness ε.
A small grey body (emissivity 0.7) is placed inside a large enclosure. Compared with an identical black body at the same temperature in the same enclosure, its net radiative heat loss is
B. 0.7 times that of the black body
For a small body in a large enclosure Q = εAσ(T1⁴ − T2⁴): the enclosure behaves as a black body because almost nothing it receives from the small body is reflected back. Loss scales with ε directly. 0.49 (ε²) wrongly applies the emissivity twice.
The fin efficiency of a straight fin is defined as the ratio of
D. the actual heat transferred by the fin to the heat it would transfer if its entire surface were at the base temperature
Efficiency compares the real fin with an ideal fin of infinite conductivity. The ratio with and without the fin is fin effectiveness, a different measure. The tip-to-base temperature ratio is 1/cosh(mL) for an insulated tip, and the ratio to an infinite fin is tanh(mL).
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |