ASRB NET Renewable Energy Sources (Solar, Wind): practice questions

ASRB NET — Farm Machinery & Power / Land & Water Management Engineering / Agricultural Structures & Process Engineering · India · Agricultural Scientists Recruitment Board (ICAR)

Original practice questions written to the published syllabus · not past papers
10worked here, free
40written to this exam in this subject
14syllabus units

About ASRB NET

ASRB NET — Farm Machinery & Power / Land & Water Management Engineering / Agricultural Structures & Process Engineering is a specialist certification exam run by Agricultural Scientists Recruitment Board (ICAR), for candidates in India. NET: 150 MCQs, 150 marks, 2 hours, −1/3 per wrong answer, English/Hindi, PG level. Combined NET/ARS/SMS/STO recruitment runs prelims, mains and interview.

Official site: pw.live.

We have not been able to confirm these details against the exam body's own specification, so fees, dates and pass marks are left out on purpose. Check the current format, eligibility, fees and dates on the official site.

Renewable Energy Sources (Solar, Wind) in ASRB NET

Theory-heavy MCQs on renewable energy in agriculture: solar thermal devices and their tests, PV system components, windmill types and solidity, micro-hydro turbines.

Solar thermal, solar PV, wind and micro-hydro for farms, from sun geometry to sizing a solar pump.

Our 40 ASRB NET questions in this subject: 25 easy, 15 medium, 0 hard, across 14 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ASRB NET and are not shown on any other exam's page.

Question 1 · easy

The tonne of oil equivalent (toe), under the International Energy Agency convention, equals:

  1. 4.1868 GJ
  2. 418.68 GJ
  3. 41.868 MJ
  4. 41.868 GJ
Answer and working

D. 41.868 GJ

By IEA convention 1 toe = 10⁷ kcal = 41.868 GJ. The other values are powers-of-ten slips of the same digits.

Question 2 · easy

In most agricultural-engineering textbooks following the World Meteorological Organization (1981) value, the solar constant is taken as about:

  1. 1000 W/m²
  2. 1367 kW/m²
  3. 1367 W/m²
  4. 136.7 W/m²
Answer and working

C. 1367 W/m²

1367 W/m² is the WMO value used in most texts (older books use 1353 and recent satellite measurements about 1361 W/m²). 1000 W/m² is a ground-level reference, and the others are unit or decimal slips.

Question 3 · easy

A selective absorber coating for a solar collector is one with:

  1. Low solar absorptance and high thermal (infrared) emittance
  2. High solar absorptance and low thermal (infrared) emittance
  3. High absorptance and high emittance, like matt black paint
  4. High transmittance to solar radiation
Answer and working

B. High solar absorptance and low thermal (infrared) emittance

A selective surface absorbs short-wave sunlight well (α ≈ 0.9 or more) but emits little long-wave radiation at plate temperature (ε ≈ 0.1 or less), cutting radiative loss. Ordinary black paint has both α and ε near 0.9, so it is not selective; transmittance is a property of the cover.

Question 4 · easy

In a flat-plate collector, the glass cover is used mainly because it:

  1. Absorbs most of the incoming solar radiation itself and passes that heat by conduction to the working fluid in the riser tubes
  2. Increases the concentration ratio of the collector
  3. Transmits short-wave solar radiation but is nearly opaque to long-wave radiation from the absorber, and cuts convection
  4. Raises the emittance of the absorber
Answer and working

C. Transmits short-wave solar radiation but is nearly opaque to long-wave radiation from the absorber, and cuts convection

Glass passes most sunlight and traps both infrared emission and a still air layer — the greenhouse effect. It is not meant to absorb (that is the plate's job) and it does not concentrate.

Question 5 · easy

A concentrating collector with a high concentration ratio can use:

  1. Only beam radiation
  2. Only diffuse radiation
  3. Beam (direct) and diffuse radiation equally
  4. Only ground-reflected radiation
Answer and working

A. Only beam radiation

Optics can focus only rays arriving from a known direction, so a high-concentration collector uses beam radiation only and must track the sun. Diffuse light arrives from the whole sky; low-concentration CPCs accept a small fraction of it. Beam radiation is the direct component from the sun's disc.

Question 6 · easy

A thermosiphon solar water heater circulates water without a pump because:

  1. Heated water becomes less dense and rises to a storage tank placed above the collector
  2. A PV-powered pump is hidden inside the collector
  3. Water is pushed by the mains pressure through a one-way valve
  4. Steam produced in the collector builds pressure that drives the water up into the storage tank
Answer and working

A. Heated water becomes less dense and rises to a storage tank placed above the collector

Natural circulation is driven by the density difference between warm water in the collector and cooler water in the tank, which must sit higher than the collector. Forced-circulation systems need a pump; normal systems do not boil water.

Question 7 · easy

For a PV cell, the short-circuit current Isc is approximately proportional to:

  1. Irradiance
  2. The logarithm of irradiance
  3. The square of cell temperature
  4. The open-circuit voltage
Answer and working

A. Irradiance

Isc ≈ light-generated current, proportional to the photon flux and hence to irradiance. Voc, not Isc, varies with the logarithm of irradiance.

Question 8 · medium

The purpose of bypass diodes connected across groups of cells in a PV module is to:

  1. Stop the battery discharging back through the module at night, which would otherwise flatten it
  2. Increase the open-circuit voltage of the module
  3. Convert DC to AC
  4. Let current flow around shaded cells so they are not driven into reverse bias and overheated
Answer and working

D. Let current flow around shaded cells so they are not driven into reverse bias and overheated

A shaded cell in a series string can be forced into reverse bias and dissipate power as heat (a hot spot). The bypass diode conducts instead, protecting the cell at the cost of that group's output. Blocking diodes, not bypass diodes, stop night-time reverse current.

Question 9 · easy

A 12 V, 150 Ah battery is used to 50% depth of discharge. How much energy can it deliver per cycle?

  1. 0.9 kWh
  2. 1.8 kWh
  3. 150 Wh
  4. 75 kWh
Answer and working

A. 0.9 kWh

Nominal energy = 12 × 150 = 1800 Wh = 1.8 kWh; at 50% DoD the usable energy is 0.9 kWh. 1.8 kWh ignores DoD; 150 Wh forgets the voltage; 75 kWh is a unit slip.

Question 10 · easy

Most large modern electricity-generating wind turbines are:

  1. Multi-blade vertical-axis Savonius rotors
  2. Two-bladed Darrieus rotors
  3. Twenty-bladed farm windmills
  4. Three-bladed horizontal-axis turbines
Answer and working

D. Three-bladed horizontal-axis turbines

The three-bladed upwind horizontal-axis design dominates utility-scale wind because it balances efficiency, loads and noise. Savonius and many-bladed rotors suit low-power, high-torque uses.

A study plan for Renewable Energy Sources (Solar, Wind) in ASRB NET

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (50% of the 40 questions): Energy scenario (6, 15%); Measurement of solar radiation (4, 10%); Wind turbines and water-pumping windmills (4, 10%); Concentrating collectors (3, 8%); Energy storage (3, 8%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Flat-plate collectors and their efficiency (3, 8%); Photovoltaic cell physics and the I-V curve (3, 8%); Solar dryers, cookers, water heaters and stills (3, 8%); Solar radiation geometry (3, 8%); Micro-hydro (2, 5%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Power in the wind and the Betz limit (2, 5%); Solar pumps and agri-voltaics (2, 5%); Fill factor and MPPT (1, 3%); PV system sizing: on-grid and off-grid (1, 3%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Bank the easy marks: Power in the wind and the Betz limit (2 easy of 2); Fill factor and MPPT (1 easy of 1).

    Do these early in revision so they are fast on the day.

  5. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ASRB NET Renewable Energy Sources (Solar, Wind)

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.