Hydraulic Drives & Controls in ICAR AIEEA-PG

Recall of pump, valve and control-system types and of linkage control modes; at PhD level, load-sensing principles, hydrostatic transmissions, electro-hydraulic hitch control and design trade-offs.

Oil hydraulics on tractors and machines: pumps, motors, cylinders, valves and circuits.

Our 94 ICAR AIEEA-PG questions in this subject: 32 easy, 51 medium, 11 hard, across 9 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AIEEA-PG and are not shown on any other exam's page.

Question 1 · medium

A loader's controls feel spongy and the boom bounces before settling. The oil in the reservoir looks milky-foamy. The most likely physical reason for the spongy response is

  1. water raising the oil viscosity so the valves respond late
  2. a relief valve set too high so pressure overshoots each time
  3. entrained air lowering the effective bulk modulus of the oil
  4. oil too cold, making the pump deliver more flow than normal
Answer and working

C. entrained air lowering the effective bulk modulus of the oil

Air bubbles make the oil far more compressible, so the cylinder moves before pressure builds and then oscillates; foamy oil is the visible sign. Water causes milky oil and corrosion but is not the main cause of compliance. A high relief setting does not make the system spongy, and cold oil reduces rather than increases effective pump delivery.

Question 2 · medium

A pump with a displacement of 50 cm³/rev works against a pressure difference of 180 bar. Its mechanical (torque) efficiency is 90 %. The torque required at the pump shaft is

  1. 143 N·m
  2. 129 N·m
  3. 1000 N·m
  4. 159 N·m
Answer and working

D. 159 N·m

Ideal torque = V × Δp/(2π) = 50 × 10⁻⁶ × 180 × 10⁵/(2π) = 143.2 N·m. Actual input torque = ideal/ηm = 159 N·m. 143 is the ideal torque with losses ignored; multiplying the ideal torque by ηm gives 129 (the motor rule, wrong for a pump); omitting 2π gives 1000.

Question 3 · hard

An axial-piston swash-plate pump has 9 pistons of 16 mm diameter on a pitch-circle diameter of 60 mm. At a swash-plate angle of 18°, its displacement is

  1. 33.6 cm³/rev
  2. 17.6 cm³/rev
  3. 108.6 cm³/rev
  4. 35.3 cm³/rev
Answer and working

D. 35.3 cm³/rev

V = (π/4)d² × z × D × tan α = (π/4)(1.6 cm)² × 9 × 6.0 cm × tan 18° = 35.3 cm³/rev. Using sin α instead of tan α gives 33.6; using the pitch-circle radius gives 17.6; omitting tan α gives 108.6, which would correspond to tan α = 1 (a 45° swash angle).

Question 4 · hard

In a hydrostatic transmission, a pump of 45 cm³/rev is driven at 2000 rev/min and feeds a fixed motor of 90 cm³/rev. The volumetric efficiency of the pump and of the motor is each 95 %. The motor speed is

  1. 1000.0 rev/min
  2. 950.0 rev/min
  3. 902.5 rev/min
  4. 1108.0 rev/min
Answer and working

C. 902.5 rev/min

Pump delivery = 45 × 2000 × 0.95 = 85500 cm³/min; motor speed = 85500 × 0.95/90 = 902.5 rev/min. Ignoring leakage gives 1000; applying only one efficiency gives 950.0; dividing by the efficiencies gives 1108.0.

Question 5 · medium

Two work sections of a sectional mobile valve are connected in parallel. If the operator moves both spools fully at once, one lifting a light load and one a heavy load,

  1. both loads move at speeds proportional to their load pressures
  2. the lighter load moves first and takes most of the flow
  3. the heavier load moves first because the sections are in parallel
  4. neither moves because the two sections cancel each other's flow
Answer and working

B. the lighter load moves first and takes most of the flow

In parallel sections each spool is fed from a common gallery, so pump pressure rises only to the lighter load's needs and that function takes the flow. Series sections pass oil from one to the next so both can move but pressures add; a tandem arrangement gives the upstream section priority.

Question 6 · easy

For a direct-acting relief valve, the term 'pressure override' means

  1. the pressure at which the valve first begins to pass oil to tank
  2. the difference between the full-flow pressure and the cracking pressure
  3. the maximum pressure the valve body can withstand before failure
  4. the pressure drop across the valve when it is fully closed
Answer and working

B. the difference between the full-flow pressure and the cracking pressure

Cracking pressure is where the valve first opens; as flow through it rises the spring compresses further, so pressure at full flow is higher. The difference is the override. Pilot-operated relief valves have much smaller override than direct-acting ones.

Question 7 · easy

A fixed-displacement pump delivers 60 L/min. An operator holds the lift lever against a stalled cylinder so all the flow passes over a relief valve set at 175 bar. The rate of heat generation is

  1. 175 kW
  2. 17.5 kW
  3. 1050 kW
  4. 1.75 kW
Answer and working

B. 17.5 kW

All the hydraulic power becomes heat: 175 × 60/600 = 17.5 kW. Using the MPa shortcut with bar gives 175; 1050 kW treats 60 L/min as 60 L/s; 1.75 is a factor-of-ten slip. This is why holding a lever at the end of stroke overheats the oil.

Question 8 · medium

An uncompensated needle valve passes 20 L/min to a motor when the pressure drop across it is 25 bar. If load changes make the pressure drop across the valve 100 bar with the same opening, the flow becomes about

  1. 80 L/min
  2. 40 L/min
  3. 20 L/min
  4. 10 L/min
Answer and working

B. 40 L/min

Orifice flow varies with the square root of pressure drop: Q₂ = 20 × √(100/25) = 20 × 2 = 40 L/min. Assuming flow proportional to Δp gives 80; assuming it stays constant (as with a pressure-compensated valve) gives 20; 10 inverts the ratio, 20 × √(25/100). This load sensitivity is why compensated flow controls are used where speed must be steady.

Question 9 · medium

In a closed-centre load-sensing system, with one function working at a load pressure of 120 bar and the pump margin set at 20 bar, the pump outlet pressure is about

  1. 120 bar
  2. 100 bar
  3. 140 bar
  4. the maximum pressure-limiter setting
Answer and working

C. 140 bar

A load-sensing pump keeps its outlet a fixed margin above the highest load pressure fed back through the signal line: 120 + 20 = 140 bar. 120 bar would leave no pressure drop to drive flow across the spool; 100 bar would be below the load; full limiter pressure would be a constant-pressure system, not load sensing.

Question 10 · easy

ISO 730 defines categories (1, 2, 3, 4 and narrow variants) for the rear three-point linkage of agricultural tractors. What does the category mainly specify?

  1. The maximum hydraulic pressure that the tractor's lift pump may supply
  2. The type of control system, whether draft, position or intermix control
  3. The hitch-pin diameters and the spacing of the linkage attachment points
  4. The quick-coupler type and size used on the tractor's remote valves
Answer and working

C. The hitch-pin diameters and the spacing of the linkage attachment points

Categories match tractor power ranges and fix the pin diameters and spacing so implements fit tractors of the same category. Pump pressure and control mode are not set by ISO 730, and quick couplers are covered by other standards such as ISO 5675 and ISO 16028.

A study plan for Hydraulic Drives & Controls in ICAR AIEEA-PG

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (41% of the 94 questions): Hydraulic cylinders (13, 14%); Hydraulic pumps: gear, vane and piston (13, 14%); Pressure relief and flow control valves (13, 14%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Tractor hydraulic systems (12, 13%); Hydraulic motors (10, 11%); Principles of fluid power (10, 11%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Pressure drop and heat generation (9, 10%); Directional control valves (7, 7%); Open-centre, closed-centre and load-sensing circuits (7, 7%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Hydraulic cylinders (3 hard of 13), Hydraulic pumps: gear, vane and piston (3 hard of 13), Pressure drop and heat generation (2 hard of 9).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Principles of fluid power (6 easy of 10); Open-centre, closed-centre and load-sensing circuits (3 easy of 7).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AIEEA-PG Hydraulic Drives & Controls

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.