LAISHA
Open Laisha

NCEES PE Agricultural and Biological Engineering Protected Cultivation & Greenhouse Engineering: practice questions

NCEES PE Agricultural and Biological Engineering · USA · NCEES (ASABE is the content partner)

Original practice questions written to the published syllabus · not past papers
10worked here, free
38written to this exam in this subject
11syllabus units

About NCEES PE Agricultural and Biological Engineering

NCEES PE Agricultural and Biological Engineering is a licensing and registration exam run by NCEES (ASABE is the content partner), for candidates in USA. Computer-based, 85 questions, 9.5-hour appointment (8.5 hours of exam). Once a year (next: 28 Oct 2026). Closed book with the electronic NCEES handbook and supplied searchable ASABE standards; SI and US customary units.

Source: ncees.org.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Protected Cultivation & Greenhouse Engineering in NCEES PE Agricultural and Biological Engineering

Facilities and Structures lists greenhouses: heat loss from U A ΔT plus infiltration, ventilation rate from a solar heat balance, fan and pad sizing, psychrometrics of evaporative cooling, and structural loads, in SI and US customary units.

Designing greenhouses and controlling the climate inside them, with the plastics and soilless systems that go with them.

Our 38 NCEES PE Agricultural and Biological Engineering questions in this subject: 1 easy, 22 medium, 15 hard, across 11 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to NCEES PE Agricultural and Biological Engineering and are not shown on any other exam's page.

Question 1 · medium

A free-standing single-span greenhouse is to be built at 45° N for winter vegetable production. Which ridge orientation gives the most winter light under the classic North American guidance?

  1. Ridge running north–south, so morning and evening sun strike both slopes equally
  2. Ridge parallel to the prevailing wind, because wind direction controls winter light
  3. Any direction at all, because diffuse light dominates at this latitude in winter
  4. Ridge running east–west, so the long south roof faces the low winter sun
Answer and working

D. Ridge running east–west, so the long south roof faces the low winter sun

Above about 40° latitude the low winter sun is best intercepted by a long south-facing roof, which an east–west ridge gives a free-standing house. North–south ridges are chosen for gutter-connected houses so that gutter shadows move; wind direction governs vent placement, not light.

Question 2 · medium

Taking air density as 1.2 kg/m³, what is the wind velocity pressure q = 0.5ρV² for a design wind speed of 35 m/s on a greenhouse?

  1. 1,470 Pa
  2. 21 Pa
  3. 368 Pa
  4. 735 Pa
Answer and working

D. 735 Pa

q = 0.5 × 1.2 × 35² = 0.5 × 1.2 × 1,225 = 735 Pa. Leaving out the 0.5 gives 1,470 Pa; forgetting to square V gives 21 Pa; 368 Pa halves twice. The code then multiplies q by pressure coefficients for each face.

Question 3 · medium

A greenhouse of 3,000 m³ leaks 1.5 air changes per hour. With ρcp = 1,200 J m⁻³ K⁻¹ and an inside–outside difference of 15 K, what is the sensible heat lost by leakage?

  1. 22.5 W
  2. 81.0 MW
  3. 15.0 kW
  4. 22.5 kW
Answer and working

D. 22.5 kW

Q = ρcp N V ΔT / 3,600 = 1,200 × 1.5 × 3,000 × 15 / 3,600 = 22,500 W = 22.5 kW. 81.0 MW forgets to divide by 3,600 s per hour; 22.5 W comes from using ρcp = 1.2 (the kJ value) as if it were in J; 15.0 kW drops the 1.5 air changes to one.

Question 4 · hard

Summer design: τ = 0.75, outside irradiance 900 W/m², floor area 2,000 m², fraction of absorbed energy used for evapotranspiration E = 0.4, cover area 3,000 m² with U = 5.5 W m⁻² K⁻¹, and the inside may run 5 K above outside. With ρcp = 1,200 J m⁻³ K⁻¹, what ventilation rate is needed?

  1. 135 m³/s
  2. 121 m³/s
  3. 211 m³/s
  4. 146 m³/s
Answer and working

B. 121 m³/s

Sensible gain = 0.75 × 900 × 2,000 × (1 − 0.4) = 810,000 W; cover loss = 5.5 × 3,000 × 5 = 82,500 W; Qv = (810,000 − 82,500) / (1,200 × 5) = 121 m³/s. Ignoring the cover loss gives 135; ignoring evapotranspiration gives 211; using 1,000 J m⁻³ K⁻¹ (cp without density) gives 146.

Question 5 · hard

In still air, a greenhouse has 30 m² of effective opening split between side and roof vents whose centres are 4 m apart. Inside is 32 °C and outside 26 °C. Using Q = Cd A √[2gΔh(Ti − To)/Ti] with Cd = 0.65, what is the stack ventilation rate?

  1. 74.8 m³/s
  2. 24.2 m³/s
  3. 37.3 m³/s
  4. 17.1 m³/s
Answer and working

B. 24.2 m³/s

Ti must be absolute: 305.15 K. Q = 0.65 × 30 × √(2 × 9.81 × 4 × 6 / 305.15) = 0.65 × 30 × 1.242 = 24.2 m³/s. Using 32 °C in the denominator gives 74.8; leaving out Cd gives 37.3; dropping the 2 gives 17.1.

Question 6 · medium

Why does a greenhouse with both low side vents and high roof vents ventilate better in calm weather than one with roof vents alone?

  1. Side vents admit wind from all directions, so wind ventilation never stops
  2. Roof vents alone cannot open in calm weather because no wind lifts them
  3. The height between inlet and outlet is larger, which strengthens the stack effect
  4. Two vent levels double the light entering, so the air warms and rises faster
Answer and working

C. The height between inlet and outlet is larger, which strengthens the stack effect

Stack flow rises with the square root of Δh, the vertical distance between the centres of inlet and outlet, so low inlets and high outlets help when there is no wind. In calm weather there is no wind to exploit; vents are opened by motors, not wind; and vents do not double light.

Question 7 · hard

Using the daytime balance and ignoring heat lost through the cover, what happens to the required ventilation rate if the allowed inlet-to-outlet temperature rise is reduced from 4 K to 2 K?

  1. It doubles
  2. It halves
  3. It stays the same
  4. It rises by a factor of √2
Answer and working

A. It doubles

Qv = sensible heat ÷ (ρcp ΔT), so with the heat load fixed the airflow is inversely proportional to ΔT; halving ΔT doubles it. This is why tight temperature limits make fan ventilation expensive and why evaporative cooling is added in hot weather.

Question 8 · medium

Complete combustion of propane follows C₃H₈ + 5O₂ → 3CO₂ + 4H₂O. How much CO₂ does one kilogram of propane produce?

  1. 2.75 kg
  2. 1.0 kg
  3. 3.0 kg
  4. 4.0 kg
Answer and working

C. 3.0 kg

Molar mass of propane is 44 g/mol and each mole gives 3 mol CO₂ (3 × 44 = 132 g), so 132/44 = 3.0 kg CO₂ per kg. 2.75 kg is the methane figure (44/16); 1.0 kg counts one mole of CO₂ only; 4.0 kg uses the water moles.

Question 9 · medium

What is the occupational exposure limit for CO₂, averaged over an eight-hour working day, used in many countries including the United States?

  1. 1,000 ppm
  2. 50,000 ppm
  3. 5,000 ppm
  4. 500 ppm
Answer and working

C. 5,000 ppm

The common 8-hour limit is 5,000 ppm (0.5%). Enrichment set points of roughly 700–1,000 ppm are far below it, but faulty dosing or a burst cylinder can exceed it, so alarms are fitted. 1,000 ppm is a typical enrichment set point, not a safety limit; 500 ppm is close to outdoor air. 50,000 ppm is a factor-of-ten slip (5%).

Question 10 · hard

A recipe needs 250 mg/L potassium from potassium nitrate containing 38% K. The stock is dosed by a 1:200 injector. What concentration of potassium nitrate is needed in the stock tank?

  1. 131.6 g/L
  2. 65.8 g/L
  3. 0.66 g/L
  4. 50.0 g/L
Answer and working

A. 131.6 g/L

Salt in the final solution = 250 / 0.38 = 658 mg/L. The stock is 200 times stronger: 657.9 × 200 = 131,579 mg/L = 131.6 g/L. 65.8 g/L assumes a 1:100 ratio; 0.66 g/L is the final strength, not the stock; 50.0 g/L forgets that the salt is only 38% K.

A study plan for Protected Cultivation & Greenhouse Engineering in NCEES PE Agricultural and Biological Engineering

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (47% of the 38 questions): Forced ventilation (5, 13%); Greenhouse types and orientation (5, 13%); CO2 enrichment (4, 11%); Fan-pad and fogging cooling (4, 11%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Glazing and cladding materials (4, 11%); Greenhouse heat balance (4, 11%); Natural ventilation (4, 11%); Greenhouse heating (3, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Automation of climate control (2, 5%); Hydroponics and aeroponics (2, 5%); Plastics in agriculture: mulch and lining (1, 3%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Plastics in agriculture: mulch and lining (1 hard of 1), Greenhouse heat balance (3 hard of 4), Natural ventilation (2 hard of 4).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Forced ventilation (1 easy of 5).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — NCEES PE Agricultural and Biological Engineering Protected Cultivation & Greenhouse Engine

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.