ICAR AICE-JRF/SRF Dairy Analysis & Instrumental Methods: practice questions
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR
Original practice questions written to the published syllabus · not past papers
10worked here, free
89written to this exam in this subject
13syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Dairy Analysis & Instrumental Methods in ICAR AICE-JRF/SRF
Adulteration and analytical methods, and instrumental analysis: principles of spectroscopy, chromatography, electrophoresis and immunoassays, infrared analysers and their calibration, and method validation.
Testing milk and dairy products: platform tests, reference methods, adulterant detection and modern instruments.
Our 89 ICAR AICE-JRF/SRF questions in this subject: 17 easy, 45 medium, 27 hard, across 13 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · hard
Milk from a herd with high mastitis passes the clot-on-boiling test but flocculates in the alcohol test. Why?
The COB test is more sensitive to acidity than the alcohol test at every level
Alcohol stability falls with abnormal milk before COB fails
Mastitic milk contains alcohol-producing yeasts
Boiling removes mastitis bacteria, so the COB test cannot detect them
Answer and working
B. Alcohol stability falls with abnormal milk before COB fails
Alcohol stability falls with salt and protein changes in abnormal milk before the milk coagulates on boiling.
Question 2 · hard
What is the purpose of intercorrection factors in infrared milk analysers?
To adjust each reading for the breed and lactation stage of the cow that gave the milk
To convert micrometres into nanometres
To correct for room humidity
To correct each component's reading for the influence of the other components
Answer and working
D. To correct each component's reading for the influence of the other components
Fat absorbs slightly at the protein wavelength and so on; intercorrection removes these cross-effects.
Question 3 · hard
Why are quantitative methods and limits needed to prove addition of urea to milk?
Urea evaporates during testing
Milk contains urea naturally, so its presence alone proves nothing
Urea is identical to lactose in all chemical tests, so it cannot be told apart from it
Urea is detected only by the Gerber test
Answer and working
B. Milk contains urea naturally, so its presence alone proves nothing
Natural urea varies with feeding; only levels above a limit indicate addition.
Question 4 · hard
Which method can detect cow milk added to buffalo milk?
An immunological test with antiserum against cow milk proteins
The Gerber fat test
The clot-on-boiling test, since cow milk clots sooner than buffalo milk
The lactometer test
Answer and working
A. An immunological test with antiserum against cow milk proteins
Species-specific antibodies, electrophoresis or DNA tests identify cow milk.
Question 5 · hard
Why do animal body fats such as tallow escape detection by the phytosterol acetate test?
They dissolve the sterol acetates completely
They have a much higher Reichert-Meissl value than genuine ghee
They contain more phytosterols than vegetable oils
They contain cholesterol, not phytosterols, like milk fat
Answer and working
D. They contain cholesterol, not phytosterols, like milk fat
Body fats lack phytosterols; they lower RM and saponification values and need GC or other tests.
Question 6 · medium
A calibration line has slope 0.05 absorbance units per milligram per litre and intercept 0.01. A sample reads 0.36. What is its concentration?
7.0 milligrams per litre
0.018 milligrams per litre
7.2 milligrams per litre
18 milligrams per litre
Answer and working
A. 7.0 milligrams per litre
c = (0.36 - 0.01)/0.05 = 7.0 mg/L. 7.2 ignores the intercept.
Question 7 · hard
Why is lanthanum added when calcium in milk is determined by flame atomic absorption?
To dissolve the fat
To overcome phosphate interference that lowers the calcium signal
To raise the flame temperature
To provide the characteristic light source needed for calcium in the flame
Answer and working
B. To overcome phosphate interference that lowers the calcium signal
Phosphate forms refractory calcium compounds; lanthanum releases calcium.
Question 8 · medium
The EU reference method for cow milk in sheep, goat or buffalo cheese uses:
The Reichert-Meissl value of the fat extracted from the cheese
Gerber fat analysis
Isoelectric focusing of gamma-caseins after plasmin digestion
SDS-PAGE of whey proteins
Answer and working
C. Isoelectric focusing of gamma-caseins after plasmin digestion
IEF of gamma-caseins distinguishes bovine from other species.
Question 9 · hard
With a standard deviation of 0.004 and a calibration slope of 0.08 per unit, what is the limit of detection using 3.3 s/slope?
About 3.3 units
About 0.5 unit
About 0.013 unit
About 0.17 unit
Answer and working
D. About 0.17 unit
LOD = 3.3 x 0.004/0.08 = 0.165. 0.5 is the LOQ (10 s/slope).
Question 10 · medium
Repeatability refers to precision measured under which conditions?
Same analyst, equipment and laboratory over a short time
Different samples from the same batch
Different methods on the same sample
Different laboratories with different analysts
Answer and working
A. Same analyst, equipment and laboratory over a short time
Reproducibility involves different laboratories.
A study plan for Dairy Analysis & Instrumental Methods in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (47% of the 89 questions): Fat determination: Gerber, Babcock and Rose-Gottlieb (9, 10%); Protein: Kjeldahl and dye-binding; total solids and SNF (9, 10%); Spectroscopy: UV-visible, infrared, atomic absorption and flame photometry (9, 10%); Method validation, reference materials and proficiency testing (8, 9%); Aflatoxin M1 detection (7, 8%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Antibiotic, pesticide and heavy-metal residue testing (7, 8%); Chromatography: TLC, GC and HPLC (7, 8%); Electrophoresis and immunoassays: SDS-PAGE, ELISA and lateral-flow tests (7, 8%); Detection of adulterants: water, starch, urea, neutralisers, detergent, vegetable fat (6, 7%); Ghee and butter fat adulteration: BR reading, Reichert-Meissl and Polenske values, sterol tests (6, 7%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Infrared milk analysers and their calibration (6, 7%); Platform tests: organoleptic, COB, alcohol, sediment, lactometer (5, 6%); Sampling of milk and dairy products (3, 3%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Detection of adulterants: water, starch, urea, neutralisers, detergent, vegetable fat (4 hard of 6), Ghee and butter fat adulteration: BR reading, Reichert-Meissl and Polenske values, sterol tests (3 hard of 6), Aflatoxin M1 detection (3 hard of 7).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Platform tests: organoleptic, COB, alcohol, sediment, lactometer (3 easy of 5); Sampling of milk and dairy products (1 easy of 3).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.