LAISHA
Open Laisha

ICAR AICE-JRF/SRF Quality Assurance, Statistical Quality Control & Laboratory Management: practice questions

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR

Original practice questions written to the published syllabus · not past papers
10worked here, free
90written to this exam in this subject
11syllabus units

About ICAR AICE-JRF/SRF

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Quality Assurance, Statistical Quality Control & Laboratory Management in ICAR AICE-JRF/SRF

Subject 34 Unit 9 asks about quality systems, standards bodies (ISO, IDF, Codex, AOAC, BIS, FSSAI), traceability and laboratory accreditation; subject 36 Unit 6 asks about quality assurance of microbiological testing, rapid methods and their validation against reference methods. Expect definition items on QC versus QA, ISO 9001 and ISO/IEC 17025, control charts and sampling plans, proficiency testing scores and shelf-life determination.

Quality systems, statistical process control, sampling inspection and running an accredited dairy laboratory.

Our 90 ICAR AICE-JRF/SRF questions in this subject: 21 easy, 41 medium, 28 hard, across 11 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.

Question 1 · easy

Which statement best distinguishes quality assurance from quality control in a dairy?

  1. QA builds a preventive system that gives confidence; QC detects nonconforming product
  2. QA tests finished product at dispatch, while QC audits the farms that supply the milk
  3. QC is carried out only by certification bodies, while QA is carried out by plant staff
  4. QA and QC are two names for the same laboratory testing done at milk reception
Answer and working

A. QA builds a preventive system that gives confidence; QC detects nonconforming product

ISO 9000 defines quality control as the part of quality management focused on fulfilling requirements (inspection and test) and quality assurance as the part focused on providing confidence that they will be fulfilled (a planned, preventive system). Calling them the same thing, or assigning QC to certification bodies, confuses the terms.

Question 2 · medium

Fill weights of 500 g cups are charted in subgroups of 5. The average range is 12 g. With D3 = 0 and D4 = 2.114, what is the upper control limit of the R chart?

  1. 6.9 g
  2. 24.0 g
  3. 36.0 g
  4. 25.4 g
Answer and working

D. 25.4 g

UCL = D4 × R̄ = 2.114 × 12 = 25.4 g; LCL = 0. 24.0 g doubles R̄; 36.0 g triples it; 6.9 g is A2 × R̄, which belongs to the X-bar chart.

Question 3 · medium

Subgroups of 5 butter samples give an average moisture range of 0.93%. With d2 = 2.326, what is the estimated process standard deviation?

  1. 0.40%
  2. 2.16%
  3. 0.19%
  4. 0.31%
Answer and working

A. 0.40%

σ̂ = R̄/d2 = 0.93/2.326 = 0.40%. 0.19% divides by n = 5; 2.16% multiplies by d2; 0.31% divides by 3.

Question 4 · medium

Why is a capability index calculated from data of an out-of-control process misleading?

  1. Capability indices can only be calculated for attribute data such as leakers
  2. An out-of-control process always gives a capability index of zero
  3. An unstable process has no stable distribution to compare with the limits
  4. The specification limits change whenever the process is out of control
Answer and working

C. An unstable process has no stable distribution to compare with the limits

Capability assumes a stable process so that its distribution predicts future output. With special causes present, the mean and spread change unpredictably, and the index describes nothing reliable. The specification itself does not change.

Question 5 · easy

What is the correct sequence of 5S?

  1. Shine, sort, sustain, standardise, set in order
  2. Sort, shine, set in order, sustain, standardise
  3. Sort, set in order, shine, standardise, sustain
  4. Set in order, sort, standardise, shine, sustain
Answer and working

C. Sort, set in order, shine, standardise, sustain

5S runs sort, set in order, shine, standardise and sustain: remove what is not needed, give everything a place, clean, make the routine standard, then keep it up.

Question 6 · hard

Which lean improvement most directly reduces milk solids lost to effluent at product changeovers?

  1. Increasing the speed of the filler above its rated speed
  2. Adding an extra inspection of every case at dispatch
  3. Pigging lines and sequencing products from plain to flavoured
  4. Holding larger stocks of finished product in the cold store for longer
Answer and working

C. Pigging lines and sequencing products from plain to flavoured

Pigging recovers product from pipes, and sequencing compatible products reduces flushes between runs, cutting both waste and changeover time. Extra stock, inspection or overspeeding add other wastes.

Question 7 · easy

In ISO/IEC 17025:2017, impartiality and confidentiality are addressed in which clause?

  1. Clause 7, process requirements
  2. Clause 6, resource requirements
  3. Clause 4, general requirements
  4. Clause 8, management system
Answer and working

C. Clause 4, general requirements

Clause 4 (general requirements) covers impartiality and confidentiality. Clause 6 covers personnel, facilities and equipment; clause 7 the testing process; clause 8 the management system.

Question 8 · hard

Routine mid-infrared milk analysers used for payment are kept accurate mainly by:

  1. Annual replacement of the infrared source lamp only
  2. Comparing results only with those of the previous day
  3. Adjusting results until they match the farmers' expectations
  4. Regular calibration against reference-method values on calibration milks
Answer and working

D. Regular calibration against reference-method values on calibration milks

MIR instruments are indirect methods calibrated against reference methods (such as Röse-Gottlieb for fat and Kjeldahl for protein) using calibration milks, with slope and intercept checks (see ISO 9622 | IDF 141 and ISO 8196 | IDF 128). Lamp replacement or day-to-day comparison alone does not ensure accuracy.

Question 9 · easy

A product's sensory score falls linearly (zero order) from 9.0 by 0.25 points per day, and the product is rejected below 6.0. What is its sensory shelf life?

  1. 24 days
  2. 12 days
  3. 6 days
  4. 36 days
Answer and working

B. 12 days

Zero order: t = (9.0 − 6.0)/0.25 = 12 days. 24 halves the rate; 36 uses the whole score from 9.0 to zero; 6 halves the time.

Question 10 · medium

Why is accelerated shelf-life testing at 30–37 °C unreliable for chilled pasteurised milk?

  1. Sensory panels cannot taste milk stored above room temperature
  2. Pasteurised milk cannot be stored above 7 °C under any circumstances
  3. The spoilage organisms at high temperature differ from those at chill
  4. Q10 values for milk are always exactly 1.0
Answer and working

C. The spoilage organisms at high temperature differ from those at chill

Raising temperature changes which micro-organisms grow and how, so the mechanism at 30 °C does not represent chill storage; real-time studies at the intended temperature are used instead. The other statements are false.

A study plan for Quality Assurance, Statistical Quality Control & Laboratory Management in ICAR AICE-JRF/SRF

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (54% of the 90 questions): Control charts for variables and attributes (15, 17%); Shelf-life determination (12, 13%); Acceptance sampling plans (11, 12%); Process capability (11, 12%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Six Sigma and lean in dairy plants (10, 11%); ISO/IEC 17025 and laboratory accreditation (8, 9%); Quality, quality control and quality assurance (8, 9%); Quality tools: Pareto, cause-and-effect, flow charts (6, 7%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Laboratory audits and proficiency testing (4, 4%); ISO 9001 and total quality management (3, 3%); Laboratory set-up, safety and chemical management (2, 2%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Laboratory set-up, safety and chemical management (2 hard of 2), ISO/IEC 17025 and laboratory accreditation (4 hard of 8), Laboratory audits and proficiency testing (2 hard of 4).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Quality, quality control and quality assurance (5 easy of 8); Six Sigma and lean in dairy plants (4 easy of 10).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AICE-JRF/SRF Quality Assurance, Statistical Quality Control & Laboratory Management

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.