ICAR AICE-JRF/SRF Microbiological Quality Assurance & Rapid Methods: practice questions

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR

Original practice questions written to the published syllabus · not past papers
10worked here, free
76written to this exam in this subject
10syllabus units

About ICAR AICE-JRF/SRF

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Microbiological Quality Assurance & Rapid Methods in ICAR AICE-JRF/SRF

Quality assurance and rapid methods: microbiological criteria and sampling plans, indicator organisms, enumeration and detection methods, ATP bioluminescence, PCR, immunoassays, biosensors, environmental monitoring, biosafety and accreditation.

How dairy laboratories sample, count, detect and certify: criteria, indicator organisms, rapid methods and lab quality systems.

Our 76 ICAR AICE-JRF/SRF questions in this subject: 13 easy, 38 medium, 25 hard, across 10 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.

Question 1 · medium

Which organism is typically the subject of a food safety criterion rather than a process hygiene criterion?

  1. Coagulase-positive staphylococci in cheese during manufacture
  2. Escherichia coli in raw-milk butter
  3. Enterobacteriaceae in pasteurised milk
  4. Listeria monocytogenes
Answer and working

D. Listeria monocytogenes

Food safety criteria concern pathogens such as L. monocytogenes, Salmonella and Cronobacter; the others are process hygiene indicators.

Question 2 · medium

Process hygiene limits are commonly derived from:

  1. Consumer taste panels
  2. Shelf-life labels
  3. Data on what well-run processes achieve
  4. Infective doses of pathogens
Answer and working

C. Data on what well-run processes achieve

They reflect good practice, so exceeding them signals a process problem needing investigation.

Question 3 · hard

If 100 colonies are counted on a plate, the Poisson standard deviation is:

  1. 100 colonies, a relative uncertainty of 100%
  2. 50 colonies, a relative uncertainty of 50%
  3. 1 colony, a relative uncertainty of 1%
  4. 10 colonies, a relative uncertainty of 10%
Answer and working

D. 10 colonies, a relative uncertainty of 10%

For a Poisson count the SD is √N = √100 = 10, which is 10% of the count.

Question 4 · hard

ISO 11133 deals with:

  1. Detection of Salmonella
  2. Accreditation bodies
  3. Preparation and performance testing of culture media
  4. Laboratory biosafety cabinets
Answer and working

C. Preparation and performance testing of culture media

Each batch of medium is tested with defined strains for productivity and selectivity.

Question 5 · hard

A real-time PCR standard curve has a slope of −3.6. The amplification efficiency is:

  1. 90%
  2. 36%
  3. 110%
  4. 100%
Answer and working

A. 90%

E = 10^(−1/slope) − 1 = 10^(1/3.6) − 1 = 0.896, about 90%. A slope of −3.32 gives 100%.

Question 6 · medium

Surface plasmon resonance detects binding by a change in:

  1. Colony colour
  2. Refractive index at a metal surface
  3. Electric current at an enzyme electrode
  4. Mass on a quartz crystal
Answer and working

B. Refractive index at a metal surface

SPR is an optical label-free method used, for example, for antibiotic residues in milk.

Question 7 · medium

An amperometric biosensor measures:

  1. Potential at zero current
  2. Resonant frequency
  3. Refractive index
  4. Current
Answer and working

D. Current

Amperometric sensors measure current; potentiometric ones measure potential; impedimetric ones measure impedance.

Question 8 · hard

In routine dairy practice, biosensors are most established for:

  1. Antibiotic residues and somatic cell or mastitis detection
  2. Detection of single Listeria cells in 25 g without enrichment
  3. Accreditation of laboratories
  4. Replacement of all reference methods
Answer and working

A. Antibiotic residues and somatic cell or mastitis detection

Most pathogen biosensors remain in research because of matrix effects and low target numbers.

Question 9 · medium

Most routine environmental samples are usually taken from zones 2 and 3 because:

  1. Zones 2 and 3 are easier to clean and sanitise than food-contact surfaces
  2. Zone 1 sampling is forbidden
  3. They warn early, before zone 1 is contaminated
  4. These zones never contain Listeria
Answer and working

C. They warn early, before zone 1 is contaminated

The aim is to find harbourage before it reaches product contact surfaces.

Question 10 · medium

The WHO Laboratory Biosafety Manual, 4th edition (2020), emphasises:

  1. Fixed lab grades only
  2. Testing only in BSL-4
  3. Local risk assessment
  4. Removing all PPE
Answer and working

C. Local risk assessment

Controls are chosen from an assessment of agents and procedures rather than a fixed level alone.

A study plan for Microbiological Quality Assurance & Rapid Methods in ICAR AICE-JRF/SRF

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (51% of the 76 questions): Laboratory accreditation: ISO/IEC 17025 (10, 13%); Rapid methods: ATP bioluminescence, PCR, real-time PCR, immunoassays (10, 13%); Two- and three-class sampling plans (10, 13%); Biosensors in dairy safety (9, 12%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Environmental monitoring programmes (9, 12%); Detection and isolation of pathogens (8, 11%); Biosafety levels and good microbiological practice (7, 9%); Microbiological criteria and how they are set (6, 8%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Standard plate count and other enumeration methods (4, 5%); Indicator organisms: coliforms, Enterobacteriaceae, E. coli (3, 4%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Indicator organisms: coliforms, Enterobacteriaceae, E. coli (3 hard of 3), Standard plate count and other enumeration methods (2 hard of 4), Detection and isolation of pathogens (3 hard of 8).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Rapid methods: ATP bioluminescence, PCR, real-time PCR, immunoassays (3 easy of 10); Biosafety levels and good microbiological practice (2 easy of 7).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AICE-JRF/SRF Microbiological Quality Assurance & Rapid Methods

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.