ICAR AIEEA-PG / PGS — Code 18 Food Science Technology · India · ICAR through the National Testing Agency
Original practice questions written to the published syllabus · not past papersICAR AIEEA-PG / PGS — Code 18 Food Science Technology is a postgraduate admission exam run by ICAR through the National Testing Agency, for candidates in India. Computer-based, multiple choice, +4/−1 marking.
Source: icar.org.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Keeping the plant clean and verified clean: soils and detergents, cleaning-in-place and cleaning-out-of-place, sanitisers and their validation, environmental monitoring for pathogens, personnel hygiene, pest management and water and waste hygiene.
Our 53 ICAR AIEEA-PG / PGS questions in this subject: 19 easy, 34 medium, 0 hard, across 13 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AIEEA-PG / PGS and are not shown on any other exam's page.
Which cleaning approach suits polymeric ultrafiltration membranes that tolerate only moderate pH and temperature?
C. Enzyme detergents with proteases
Enzyme-based detergents work at mild pH and temperature and remove protein and fat from membranes without damaging them; strong caustic, HCl and abrasion can destroy many membranes.
What is an advantage of iodophor sanitisers?
A. Their amber colour shows that sanitiser is present
The colour gives a visual check of presence and approximate strength. Iodophors lose iodine above about 50 °C, stain plastics and work best at acidic pH.
Water at 1000 kg/m³ and viscosity 0.001 Pa·s flows at 1.5 m/s in a 50 mm pipe during CIP. What is the Reynolds number?
B. 75 000
Re = ρvD/μ = 1000 × 1.5 × 0.05/0.001 = 75 000, well above the turbulent threshold of about 4000. 750 takes μ as 0.1 Pa·s; 75 000 000 uses the diameter in millimetres; 1 500 000 omits the diameter.
What is a main advantage of a single-use CIP system over a re-use system?
A. No soil carry-over between circuits
Fresh solution each time avoids cross-contamination and suits heavily soiled circuits. Re-use systems use less chemical; both systems heat solutions and must record parameters.
Which items are typically cleaned out of place?
D. Small parts such as gaskets, valves and blades
Small parts and equipment for solid foods are dismantled and cleaned in COP tanks or by hand. Pipelines, tanks, heat exchangers and evaporators are cleaned in place.
Why is a neutralising buffer used to moisten swabs for microbiological verification after sanitising?
B. To stop residual sanitiser killing organisms after sampling
Without neutralisation, sanitiser carried on the swab keeps acting during transport, giving falsely low counts. The buffer is not a growth enhancer, protein solvent or biocide.
Who should carry out the pre-operational inspection of a cleaned line?
D. A trained person other than the cleaner
Independent inspection by someone trained, often a quality or supervisory staff member, is more reliable than self-checking. Visitors and contractors are not responsible.
What does a CIP record of flow, temperature, conductivity and time for each phase provide?
B. Verification that the validated cycle was delivered
The records show that each run met its validated parameters; validation itself is a separate study. Records are not counts and do not replace environmental monitoring.
Why are cells in a biofilm harder to kill with sanitisers than the same cells in suspension?
C. The matrix shields the cells, which also grow differently
EPS limits penetration and reacts with oxidising agents, and biofilm cells grow slowly and express stress responses, giving tolerance often 10 to 1000 times higher. Biofilms are mostly vegetative cells and alive.
Which organisms form biofilms in the warm sections of milk-powder plants and cause quality problems in powders?
D. Thermophilic spore-formers such as Geobacillus
Thermophiles grow at 45 to 65 °C in preheaters and evaporators and shed spores into the product during long runs. Pseudomonas is a cold-chain organism; lactic and mould contaminants are not the main powder problem.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.