LAISHA
Open Laisha

ICAR AICE-JRF/SRF Evaporation & Drying in Dairy Plants: practice questions

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering · India · NTA for ICAR

Original practice questions written to the published syllabus · not past papers
10worked here, free
69written to this exam in this subject
12syllabus units

About ICAR AICE-JRF/SRF

ICAR AICE-JRF/SRF (PhD): Dairy Chemistry, Dairy Microbiology, Dairy Technology, Dairy Engineering is a PhD, fellowship and lectureship exam run by NTA for ICAR, for candidates in India.

Source: icar.org.in.

Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.

Evaporation & Drying in Dairy Plants in ICAR AICE-JRF/SRF

Unit 2: evaporation techniques and evaporators, drying fundamentals and dryer types, spray dryers, separation and product recovery. Unit 1: freezing, freeze drying and freeze concentration. Expect mass and energy balances, steam economy, TVR and MVR principles, psychrometric calculations and spray-dryer design questions.

Evaporators and dryers for milk and whey: design, energy economy, operation and powder engineering.

Our 69 ICAR AICE-JRF/SRF questions in this subject: 4 easy, 45 medium, 20 hard, across 12 units.

10 practice questions, worked

Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.

These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.

Question 1 · hard

An effect evaporates 2,000 kg/h of water at 70 °C (latent heat 2,330 kJ/kg). With U = 2.5 kW/m² K and ΔT = 10 K, what heating area is needed (ignoring sensible heat)?

  1. 186,400 m²
  2. 129.4 m²
  3. 51.8 m²
  4. 518 m²
Answer and working

C. 51.8 m²

Q = 2,000 × 2,330 ÷ 3,600 = 1294 kW; A = 1294 ÷ (2.5 × 10) = 51.8 m². 518 m² ignores ΔT; 129.4 m² ignores U; 186,400 m² forgets to convert hours to seconds.

Question 2 · medium

A spray dryer uses 2,200 kW of heat to evaporate 1,000 kg/h of water. What is its specific energy consumption?

  1. 7.92 MJ/kg
  2. 2.20 MJ/kg
  3. 2.20 kJ/kg
  4. 0.45 MJ/kg
Answer and working

A. 7.92 MJ/kg

2,200 kW × 3,600 s = 7,920,000 kJ/h ÷ 1,000 kg = 7,920 kJ/kg = 7.92 MJ/kg. 2.20 MJ/kg forgets the hour-to-second conversion; 2.20 kJ/kg divides kW by kg/h directly; 0.45 inverts the ratio.

Question 3 · medium

How much heat is needed to sublime 10 kg of ice in freeze drying (latent heat of sublimation about 2,830 kJ/kg)?

  1. 28.3 MJ
  2. 22.6 MJ
  3. 3.34 MJ
  4. 2.83 MJ
Answer and working

A. 28.3 MJ

10 × 2,830 = 28,300 kJ = 28.3 MJ. 2.83 MJ slips a decimal; 22.6 MJ uses the latent heat of vaporisation; 3.34 MJ uses the latent heat of fusion.

Question 4 · medium

A concentrate leaves an evaporator at 48% solids from feed at 12% solids. What is the concentration factor by mass?

  1. 0.25
  2. 3.0
  3. 36
  4. 4.0
Answer and working

D. 4.0

48 ÷ 12 = 4.0. 36 subtracts; 0.25 inverts; 3.0 uses (48 − 12) ÷ 12.

Question 5 · hard

Why is skim milk usually not concentrated much above about 50% solids before spray drying?

  1. Protein dissolves into the vapour and is lost to the condenser
  2. The boiling point falls below the condenser temperature
  3. Viscosity rises steeply and atomisation and heat transfer suffer
  4. Lactose crystallises completely at 50% solids and blocks every evaporator tube
Answer and working

C. Viscosity rises steeply and atomisation and heat transfer suffer

High viscosity limits both evaporator performance and atomisation.

Question 6 · medium

Why do MVR evaporators need large heating areas?

  1. The compressor raises vapour temperature only a few degrees
  2. MVR evaporators cannot recycle any latent heat
  3. MVR evaporators boil at much higher temperatures than steam units
  4. MVR evaporators operate without vacuum
Answer and working

A. The compressor raises vapour temperature only a few degrees

Small ΔT means more area for the same duty.

Question 7 · hard

Final powder moisture is governed largely by:

  1. Equilibrium moisture at outlet air temperature and humidity
  2. The fat content of the concentrate only, whatever the air conditions
  3. The inlet air humidity only
  4. The drying-chamber colour
Answer and working

A. Equilibrium moisture at outlet air temperature and humidity

Powder approaches equilibrium with the exhaust air.

Question 8 · medium

Why are fines from cyclones returned to the atomisation zone?

  1. To cool the hot inlet air
  2. To build agglomerates and recover product
  3. To raise outlet humidity
  4. To increase scorched particles
Answer and working

B. To build agglomerates and recover product

Fines stick to moist droplets.

Question 9 · medium

Why are vibrating fluid beds used for dairy powders?

  1. Cohesive, sticky powders fluidise poorly in static beds
  2. Vibration heats the powder above 200 °C
  3. Vibration removes all the free fat from the particle surfaces before packing
  4. Vibration replaces the need for air
Answer and working

A. Cohesive, sticky powders fluidise poorly in static beds

Vibration aids movement and fluidisation of cohesive powder.

Question 10 · medium

Pulse-jet cleaning in bag filters:

  1. Heats the bags to dry the powder
  2. Atomises the concentrate
  3. Removes the powder cake from the bags
  4. Cools the exhaust air
Answer and working

C. Removes the powder cake from the bags

Reverse air pulses dislodge the cake into the hopper.

A study plan for Evaporation & Drying in Dairy Plants in ICAR AICE-JRF/SRF

This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.

  1. First, the heavy units (43% of the 69 questions): Spray dryers: atomisers, chamber design, two- and three-stage drying (9, 13%); Drying fundamentals: drying rate and psychrometrics (7, 10%); Freeze drying and freeze concentration (7, 10%); Multiple-effect evaporation and steam economy (7, 10%).

    Read the manual chapters for these first and do every worked question you can find on them.

  2. Then the middle band: Energy and safety in dryers (6, 9%); Falling-film evaporators (6, 9%); Principles of evaporation and boiling-point elevation (6, 9%); Thermal and mechanical vapour recompression (6, 9%).

    Aim for one sitting per unit, then mixed questions across them.

  3. Then the lighter units: Separation and recovery of powder: cyclones and bag filters (5, 7%); Fluid-bed dryers and agglomeration (4, 6%); Drum dryers (3, 4%); Vacuum pans (3, 4%).

    Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.

  4. Leave time for the hard ones: Spray dryers: atomisers, chamber design, two- and three-stage drying (4 hard of 9), Energy and safety in dryers (2 hard of 6), Principles of evaporation and boiling-point elevation (2 hard of 6).

    Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.

  5. Bank the easy marks: Thermal and mechanical vapour recompression (1 easy of 6); Freeze drying and freeze concentration (1 easy of 7).

    Do these early in revision so they are fast on the day.

  6. Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.

Last updated · How Laisha writes and checks its pages · Report a mistake

Ask Laisha about this

Opens Laisha's chat with your question ready to send. Sign in or start free.

Unlock every question — ICAR AICE-JRF/SRF Evaporation & Drying in Dairy Plants

US$10 a month · one price worldwide · cancel any time

  • Every practice question in this subject, with full working
  • Timed exam papers and progress by unit
  • Ask Laisha to explain any answer — up to 1,000 questions a month
Free or Smarter
FreeSmarter
Grow guides, pest pages, articlesRead allRead all
Ask Laisha5 a dayUp to 1,000 a month
Exam practiceThe sample on each pageEvery question, timed papers
Crop calendar and pest alerts—For your own fields
Calculators and tools—All
Uploads and reports—100 a month, real files
10 days free for every new account, no card.