ICAR AICE-JRF/SRF Statistics, Experimental Design & Chemometrics for Food Science: practice questions
ICAR AICE-JRF/SRF (PhD) — Food Processing Technology, Food Safety & Quality, Processing and Food Engineering · India · ICAR through the National Testing Agency
Original practice questions written to the published syllabus · not past papers
10worked here, free
93written to this exam in this subject
9syllabus units
About ICAR AICE-JRF/SRF
ICAR AICE-JRF/SRF (PhD) — Food Processing Technology, Food Safety & Quality, Processing and Food Engineering is a PhD, fellowship and lectureship exam run by ICAR through the National Testing Agency, for candidates in India. Computer-based, multiple choice.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Statistics, Experimental Design & Chemometrics for Food Science in ICAR AICE-JRF/SRF
Probability, inference and the designs used in food research and quality work: factorial and response-surface designs for formulation and process optimisation, mixture designs, the statistics of sensory panels, and multivariate methods (PCA, PLS) used with spectra and chromatograms. Goes further than the general statistics subjects in Agricultural Engineering (probability-statistics-data) and Agribusiness (business-statistics) by focusing on food formulation, sensory and analytical data.
Our 93 ICAR AICE-JRF/SRF questions in this subject: 27 easy, 44 medium, 22 hard, across 9 units.
10 practice questions, worked
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to ICAR AICE-JRF/SRF and are not shown on any other exam's page.
Question 1 · easy
Which is an assumption of the standard ANOVA F test?
Equal treatment means in the population
Correlated errors within each group
Equal variances among the treatment groups
Exactly normal raw data before any fitting
Answer and working
C. Equal variances among the treatment groups
ANOVA assumes independent errors, approximately normal residuals and equal variances. Equal means is the null hypothesis being tested, not an assumption; correlated errors violate independence; normality refers to residuals, approximately.
Question 2 · medium
An assessor can taste only three of seven samples in a session without fatigue. Which design family handles this?
Randomised complete block design
Completely randomised design
Full 2^7 factorial design
Balanced incomplete block design
Answer and working
D. Balanced incomplete block design
When a block (session) cannot hold all treatments, incomplete block designs allocate subsets so that every pair appears together equally often. A complete block would need all seven samples per session.
Question 3 · medium
How many runs has a central composite design for three factors with six centre points?
20
14
26
15
Answer and working
A. 20
CCD = 2^k + 2k + centre = 8 + 6 + 6 = 20. 14 omits the centre points; 26 uses 3^k minus one; 15 is the usual Box-Behnken size for three factors.
Question 4 · hard
In response surface analysis, what does the lack-of-fit test compare?
The R² of the model against the adjusted R² of a model with fewer terms in it
The predicted optimum against the verification run made at the optimum settings
The variance of the factorial points against the variance of the axial points
Residual error not explained by the model against pure error from replicated runs
Answer and working
D. Residual error not explained by the model against pure error from replicated runs
Lack of fit splits residual error into pure error (from replicated centre points) and lack-of-fit error. A significant lack of fit means the model form is inadequate. R² comparisons and verification runs are separate checks.
Question 5 · medium
Why does a Scheffé mixture model have no intercept term?
The proportions sum to one, so an intercept is redundant with the linear terms
Because mixtures always give a zero response when all components are present
Because the intercept is replaced by the pure-error term from the centroid run
Because an intercept would make the model rotatable, which mixtures must avoid
Answer and working
A. The proportions sum to one, so an intercept is redundant with the linear terms
With Σxi = 1, a constant b0 can be absorbed into the linear terms (b0 = b0Σxi), so it cannot be estimated separately. The other reasons are false.
Question 6 · easy
For a four-component mixture, what shape is the experimental region when every component may range from 0 to 1?
A triangle
A cube
A square
A tetrahedron
Answer and working
D. A tetrahedron
The simplex for q components has q − 1 dimensions: a triangle for three components and a tetrahedron for four. A cube is the region of three independent factors.
Question 7 · easy
Liking scores for one product come from two separate consumer groups that are not normally distributed. Which test compares the groups?
Wilcoxon signed-rank test
Friedman test
McNemar test
Mann-Whitney U test
Answer and working
D. Mann-Whitney U test
Two independent groups with non-normal data call for the Mann-Whitney U (Wilcoxon rank-sum) test. The signed-rank and McNemar tests are for paired data; Friedman for three or more related samples.
Question 8 · medium
Which statistic measures agreement among several assessors' rankings of the same products?
Pearson's correlation between the first two assessors only
The coefficient of variation of each assessor's ranks
Kendall's coefficient of concordance, W, across all assessors
The chi-square goodness-of-fit statistic of the rank totals
Answer and working
C. Kendall's coefficient of concordance, W, across all assessors
Kendall's W ranges from 0 (no agreement) to 1 (complete agreement) among all assessors and is used to check panel consistency.
Question 9 · hard
Ten assessors rank three products; rank sums are 15, 20 and 25. Using the Friedman statistic 12/[bt(t + 1)] ΣR² − 3b(t + 1), and a critical chi-square of 5.99 (2 df, α = 0.05), what is the result?
5.0; significant
5.0; not significant
125.0; significant
2.5; not significant
Answer and working
B. 5.0; not significant
12/(10 × 3 × 4) = 0.1; ΣR² = 225 + 400 + 625 = 1,250; 0.1 × 1,250 = 125; minus 3 × 10 × 4 = 120 gives 5.0, below 5.99, so not significant. 125.0 forgets to subtract 120; 2.5 halves the statistic.
Question 10 · easy
What is the purpose of version control for analysis scripts?
To compress data files so they occupy less storage on the server
To speed up statistical calculations on large data sets
To record every change, so earlier versions are recoverable
To translate scripts between programming languages automatically
Answer and working
C. To record every change, so earlier versions are recoverable
Version control tracks the history of scripts, who changed what and when, and allows any earlier state to be restored.
A study plan for Statistics, Experimental Design & Chemometrics for Food Science in ICAR AICE-JRF/SRF
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
First, the heavy units (35% of the 93 questions): Factorial and fractional factorial designs (11, 12%); Multivariate methods: principal component analysis, cluster analysis and partial least squares (11, 12%); Response surface methodology: central composite and Box-Behnken designs (11, 12%).
Read the manual chapters for these first and do every worked question you can find on them.
Then the middle band: Analysis of variance: one-way, two-way and multiple comparisons (10, 11%); Calibration, limit of detection and measurement uncertainty basics (10, 11%); Completely randomised, randomised block and Latin square designs (10, 11%).
Aim for one sitting per unit, then mixed questions across them.
Then the lighter units: Mixture designs for formulation (10, 11%); Non-parametric tests used with sensory data (10, 11%); Statistical software and reproducible data analysis (10, 11%).
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Leave time for the hard ones: Response surface methodology: central composite and Box-Behnken designs (4 hard of 11), Non-parametric tests used with sensory data (3 hard of 10), Multivariate methods: principal component analysis, cluster analysis and partial least squares (3 hard of 11).
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Bank the easy marks: Analysis of variance: one-way, two-way and multiple comparisons (5 easy of 10); Non-parametric tests used with sensory data (4 easy of 10).
Do these early in revision so they are fast on the day.
Finish timed. Sit the subject as a timed set without notes, mark it, and send each wrong answer back to its unit above.