NCEES PE Agricultural and Biological Engineering · USA · NCEES (ASABE is the content partner)
Original practice questions written to the published syllabus · not past papersNCEES PE Agricultural and Biological Engineering is a licensing and registration exam run by NCEES (ASABE is the content partner), for candidates in USA. Computer-based, 85 questions, 9.5-hour appointment (8.5 hours of exam). Once a year (next: 28 Oct 2026). Closed book with the electronic NCEES handbook and supplied searchable ASABE standards; SI and US customary units.
Source: ncees.org.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Processing Systems questions use supplied ASABE standards: grain airflow resistance, equilibrium moisture relations and bin loads. Expect calculations on drying shrink, fan static pressure from airflow resistance, bulk density and bin capacity, in SI and US customary units.
The physical, frictional, aerodynamic, thermal, rheological and electrical properties of grains, fruits and foods that every machine and process is designed around.
Our 19 NCEES PE Agricultural and Biological Engineering questions in this subject: 2 easy, 9 medium, 8 hard, across 8 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to NCEES PE Agricultural and Biological Engineering and are not shown on any other exam's page.
A bucket elevator has a volumetric capacity of 40 m³/h. If it handles shelled grain of bulk density 750 kg/m³, its mass capacity is
B. 30.0 t/h
Mass capacity = volumetric capacity × bulk density = 40 × 750 = 30000 kg/h = 30.0 t/h. 53.3 t/h comes from dividing 40 000 by 750 the wrong way round; 3.0 and 300.0 t/h are factor-of-ten slips in converting kg to tonnes.
A cylindrical bin 6.0 m in diameter is filled with grain to a level depth of 8.0 m. Using a bulk density of 760 kg/m³ and ignoring compaction and the surface cone, how much grain does it hold?
A. 171.9 t
Volume = π D² h / 4 = π × 36 × 8 / 4 = 226.2 m³; mass = 226.2 × 760 = 171908 kg = 171.9 t. 687.6 t omits the /4 in the area of a circle; 43.0 t puts the radius 3.0 m into πD²/4; 226.2 is the volume in m³ mistaken for tonnes.
In the Ergun equation the viscous term of pressure drop through a packed bed is proportional to (1 − ε)²/ε³, other things equal. If fines reduce the porosity of a grain bed from 0.40 to 0.36, the viscous pressure drop is multiplied by
A. 1.56
(0.64²/0.36³)/(0.60²/0.40³) = (0.4096/0.046656)/(0.36/0.064) = 8.779/5.625 = 1.56. 1.11 is only the porosity ratio; 1.14 keeps only the (1 − ε)² factor; 1.37 keeps only the ε³ factor. A ten percent loss of porosity raises resistance by more than half, which is why spout fines matter.
When a bin is filled from a central spout without a spreader, an aeration fan later fails to cool the centre of the bin. The most likely cause is that
D. fines and broken kernels collect in the central core, lowering porosity and raising airflow resistance there
Fines fall nearly straight down under the spout while whole kernels roll outward; the fines fill voids, lower porosity and raise resistance, so air takes the easier path around the core. The reverse segregation is not what occurs. Higher porosity at the centre would draw air in, not divert it, and kernel density does not vary in that way.
A hopper-bottom grain bin must empty completely by gravity. How should the designer set the slope of the hopper floor?
A. Steeper than the emptying angle of repose of the grain at its highest expected moisture
A self-cleaning floor must be steeper than the angle at which grain stops flowing, and that angle rises with moisture, so the design uses the worst case. Using dry filling-angle data leaves wet grain hung up; a flatter slope leaves grain behind; a single fixed angle ignores the crop- and moisture-dependence that the angle of repose captures.
Why do bin design standards apply an overpressure factor to the static Janssen lateral pressure?
C. Because flow of grain during emptying produces wall pressures above the static values
Flow during discharge changes the stress state and produces lateral pressures higher than the static fill values, so codes multiply by an overpressure factor whose value differs between standards. The factor increases, not reduces, design pressure; bulk density rises with compaction rather than falling; and the vertical-to-lateral conversion uses k, not an overpressure factor.
Two spherical fruits of the same variety are hydrocooled under identical conditions with internal resistance controlling. Fruit B has twice the diameter of fruit A. The time for B's centre to reach the same fractional temperature change is
D. four times that of A, since the Fourier number αt/L² must be equal
With equal Biot number and diffusivity, equal dimensionless temperature requires equal Fo = αt/L², so t ∝ L² and doubling size quadruples time. Linear scaling ignores the square in Fo; equal diffusivity does not mean equal time when sizes differ; volume scaling (L³) overstates it.
A temperature cable shows a warm spot in the middle of a grain bin that has persisted for weeks while the grain near the wall follows the weather. The main physical reason the hot spot persists is that
A. a grain bulk has low thermal conductivity, so heat from the spot leaves very slowly without forced aeration
A grain bulk conducts poorly (on the order of 0.1–0.2 W/m·K, varying with crop and moisture), so heat generated by respiration of insects or moulds builds up locally; aeration is needed to remove it. A high diffusivity would erase the spot quickly; grain's specific heat is lower than water's; and grain is a poor conductor, not a good one.
In laminar flow of a power-law fluid in a pipe, v_max/v_mean = (3n + 1)/(n + 1). For a fruit purée with n = 0.4 flowing in an aseptic hold tube, the ratio is
C. 1.57
(3 × 0.4 + 1)/(0.4 + 1) = 2.2/1.4 = 1.57. 2.00 is the Newtonian value; designing a hold tube on 2.00 would be conservative for this purée but is not its ratio, and assuming 2.00 for a shear-thickening fluid would be unsafe. 0.64 is the inverse; 2.75 mixes up the expression.
A dryer receives 2000 kg of maize at 24% moisture (wet basis) and dries it to 14% wet basis. The mass of water removed is
A. 232.6 kg
Dry matter = 2000 × 0.76 = 1520 kg; final mass = 1520/0.86 = 1767.4 kg; water removed = 2000 − 1767.4 = 232.6 kg. 200.0 kg subtracts percentage points directly; 263.2 kg divides by (1 − M_initial) instead of (1 − M_final); 1767.4 kg is the final mass, not the water removed.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.