GATE — Agricultural Engineering (AG) · India · IITs and IISc on rotation (2027: IIT Madras)
Original practice questions written to the published syllabus · not past papersGATE — Agricultural Engineering (AG) is a postgraduate admission exam run by IITs and IISc on rotation (2027: IIT Madras), for candidates in India. Computer-based, 3 hours, 100 marks (15 General Aptitude + 85 technical: 25 one-mark and 30 two-mark questions). MCQ, MSQ and NAT; negative marking on MCQ only (−1/3 for one-mark, −2/3 for two-mark); no partial credit on MSQ. On-screen virtual calculator.
Source: gate2027.iitm.ac.in.
Checked against the exam body's published information. Formats and fees change; confirm the current edition there before you book.
Thermodynamic principles of IC engines under Farm Power: Otto and Diesel efficiency, compression and cut-off ratio, MEP, and isentropic compression temperatures, usually as numerical-answer questions. Processing sections draw on psychrometry (humidity ratio, dryer air balances, evaporative cooling) and refrigeration (COP, TR, refrigerant flow). Answers must be computed to the stated precision, so carry kelvin and kJ consistently.
Energy, work, heat and the cycles behind engines, refrigerators and dryers.
Our 36 GATE questions in this subject: 9 easy, 18 medium, 9 hard, across 7 units.
Choose an answer, then open the working. Each explanation says why the right answer is right and why the others are not.
These 10 were written to GATE and are not shown on any other exam's page.
Air at 300 K and 100 kPa is compressed reversibly and adiabatically in a diesel engine cylinder with a compression ratio of 16 (γ = 1.4). The temperature at the end of compression is about
D. 909 K
For an isentropic process T2/T1 = (V1/V2)^(γ−1) = 16^0.4, so T2 = 300 × 3.031 = 909 K. 4800 K multiplies by the volume ratio itself, 2174 K uses exponent 1/γ, and 662 K uses the pressure-ratio exponent (γ−1)/γ with a volume ratio.
Air at 300 K is compressed adiabatically through a pressure ratio of 6 in a compressor with an isentropic efficiency of 85 % (γ = 1.4). The actual delivery temperature is about
C. 536 K
T2s = 300 × 6^(0.4/1.4) = 500.6 K. ηC = (T2s − T1)/(T2 − T1), so T2 = 300 + 200.6/0.85 = 536 K. 470 K multiplies the ideal rise by 0.85 (giving less than isentropic, impossible), 501 K is the isentropic temperature, and 723 K uses a volume-ratio exponent and divides the whole temperature by η.
The air-standard efficiency of an Otto cycle with a compression ratio of 8 (γ = 1.4) is
C. 56.5 %
η = 1 − 8^(−0.4) = 1 − 0.4353 = 56.5 %. 87.5 % uses 1 − 1/r without the exponent, 43.5 % is the term 1/r^(γ−1) itself, and 64.6 % uses exponent 0.5 instead of γ − 1 = 0.4.
A tractor diesel engine is modelled as an air-standard Diesel cycle with compression ratio 16 and cut-off ratio 2 (γ = 1.4). Its efficiency is about
B. 61.4 %
η = 1 − (1/r^(γ−1)) × (rc^γ − 1)/(γ(rc − 1)) = 1 − 0.3299 × 1.1707 = 61.4 %. 67.0 % is the Otto efficiency at r = 16 (no cut-off penalty), 45.9 % drops γ from the denominator, and 34.0 % replaces the bracket with rc.
In the Diesel cycle the cut-off ratio is defined as
D. the volume at the end of heat addition divided by the volume at its start
Cut-off ratio rc = V3/V2, the expansion during constant-pressure heat addition. Total volume over clearance volume is the compression ratio, the pressure ratio describes the constant-volume part of a dual cycle, and the last ratio has no standard name.
At a fixed compression ratio, what happens to the air-standard Diesel-cycle efficiency as the load (and so the cut-off ratio) increases?
C. It decreases, because heat is added over a longer part of the expansion stroke
The factor (rc^γ − 1)/(γ(rc − 1)) grows with rc, so efficiency falls as cut-off ratio rises; heat added later in the stroke is converted less effectively. Dependence on r alone holds only for the Otto cycle, and there is no maximum at rc = 2.
In an ideal vapour-compression cycle, the enthalpies are 395 kJ/kg at evaporator exit, 425 kJ/kg at compressor exit and 250 kJ/kg at condenser exit. The COP is
D. 4.83
Refrigerating effect = 395 − 250 = 145 kJ/kg; compressor work = 425 − 395 = 30 kJ/kg; COP = 145/30 = 4.83. 5.83 is the heat-pump COP (condenser heat 175/30), 0.207 is the inverse, and 8.33 uses the condenser-exit enthalpy as the refrigerating effect.
A cold store needs 10 TR of refrigeration (1 TR = 3.517 kW). The refrigerating effect of the cycle is 145 kJ/kg. The refrigerant mass flow rate is about
C. 0.243 kg/s
ṁ = Q̇/RE = 35.17/145 = 0.243 kg/s. 14.6 is the flow per minute labelled per second, 0.069 divides TR by kJ/kg without converting to kW, and 1.17 divides by a compressor work of 30 kJ/kg instead of the refrigerating effect.
The dew-point temperature of moist air is
C. the temperature at which the air becomes saturated when cooled at constant humidity ratio
Dew point is the saturation temperature at the actual vapour pressure: cool the air at constant W until condensation begins. The wetted-wick reading is the wet-bulb temperature, adiabatic saturation defines the adiabatic-saturation temperature, and 50 % RH has no special name.
Why are psychrometric properties such as humidity ratio and enthalpy expressed per kilogram of dry air rather than per kilogram of moist air?
B. The mass of dry air stays constant through heating, cooling, humidifying and drying
In most air-handling processes water is added or removed but the dry-air flow is unchanged, so it is the natural basis. Water vapour's cp (about 1.88) is higher than dry air's, vapour mass is readily measured, and Dalton's law applies to the whole mixture.
This plan follows where our questions actually fall, so the time goes where the marks are likely to be. It is our reading of the syllabus, not the exam body's weighting.
Read the manual chapters for these first and do every worked question you can find on them.
Aim for one sitting per unit, then mixed questions across them.
Learn the definitions, classifications and standard numbers; these units are more often recalled than worked.
Come back to these after a first pass, untimed, and read every explanation, including for the options you rejected.
Do these early in revision so they are fast on the day.
Last updated · How Laisha writes and checks its pages · Report a mistake
US$10 a month · one price worldwide · cancel any time
| Free | Smarter | |
|---|---|---|
| Grow guides, pest pages, articles | Read all | Read all |
| Ask Laisha | 5 a day | Up to 1,000 a month |
| Exam practice | The sample on each page | Every question, timed papers |
| Crop calendar and pest alerts | — | For your own fields |
| Calculators and tools | — | All |
| Uploads and reports | — | 100 a month, real files |
An AI operating system for agriculture: free guides, manuals and tools written for every country.